Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Applied Analytics supplier in Romania

Process analysers for industrial gases and liquids

Founded in 1994

Request a quote

Who is Applied Analytics and what does it make?

Applied Analytics (AAI) is an American manufacturer of online process analysers, active since 1994, for the continuous measurement of chemical concentrations and physical properties in liquid or gaseous process streams. The OMA range uses absorption spectroscopy in the UV-Vis, SW-NIR or InGaAs spectral ranges, depending on the application, complemented by sample conditioning systems and sampling probes dedicated to each installation.

What sets the OMA range apart is that the analyser is matched to the application by choosing the spectral range and the wetted materials (quartz, Viton or 316L stainless steel in the standard versions) rather than relying on a single universal instrument. Dedicated variants such as the BTX, NOx, ammonia, H2S or colour analysers show a range specialised in specific process parameters, instead of a generic analyser recalibrated by hand for each compound.

For the Romanian market, Applied Analytics means access to online process analysers for refineries, petrochemicals and the chemical industry, where laboratory measurement by periodic sampling is no longer enough for continuous process control.

What do we supply from the Applied Analytics range?

ProductDescription
OMA-300 Series Process AnalyserWall-mounted analyser using absorption spectroscopy in the UV-Vis (200-800 nm), SW-NIR (400-1100 nm) or InGaAs (1550-1850 nm) ranges, for the continuous measurement of chemical concentrations and physical properties. NEMA 4 carbon steel enclosure, wetted parts in quartz, Viton and 316L stainless steel, with classification options for explosive-atmosphere areas.
OMA-206p Portable Process AnalyserPortable version of the OMA process analyser, used for spot checks or applications where installing a fixed analyser is not economically justified. It keeps the absorption spectroscopy measuring principle of the OMA range.
OMA-406R Rackmount Process Analyser19" rack-mounted version, for integration into existing control panels, using the same absorption spectroscopy technology as the rest of the OMA range, for applications where wall-mounting space is not available.
Dedicated Analysers for Specific CompoundsOMA range variants specialised in a single parameter: BTX (benzene-toluene-xylene), NOx, ammonia, hydrogen sulphide, odorant, colour and clean-in-place applications, each calibrated for the typical concentration range of the compound concerned.

Why Applied Analytics?

  • OMA range adaptable across three spectral ranges (UV-Vis, SW-NIR, InGaAs) depending on the compound measured
  • Dedicated variants for BTX, NOx, ammonia, H2S, colour and clean-in-place, not a single universal instrument
  • Integrated sample conditioning systems, sized for each process application
  • More than three decades of activity in online process analysis (company founded in 1994)
  • Wetted materials chosen for chemical compatibility (quartz, Viton, 316L stainless steel)

Which Applied Analytics codes and series are requested most often?

CodeDescription
OMA-300Wall-mounted process analyser, absorption spectroscopy
OMA-300-InGaAsOMA-300 variant in the InGaAs spectral range, 1550-1850 nm
OMA-300-CLROMA-300 variant, configured for the application
OMA-206pPortable process analyser, for spot checks
OMA-406RProcess analyser for 19-inch rack mounting
OMA BTX AnalyzerDedicated analyser for benzene, toluene and xylene
OMA NOx AnalyzerDedicated analyser for nitrogen oxides in a process stream
OMA Ammonia AnalyzerDedicated analyser for ammonia concentration
OMA H2S AnalyzerContinuous analyser for hydrogen sulphide
OMA Odorant AnalyzerDedicated analyser for odorant concentration in gas
OMA Clean-in-Place AnalyzerAnalyser for verifying clean-in-place processes
OMA Color AnalyzerDedicated analyser for measuring the colour of the process product
MicroSpec MCP-200Analyser from the Applied Analytics MicroSpec range

Where is Applied Analytics equipment used?

  • Refineries and petrochemicals — continuous monitoring of compounds in process streams
  • Chemical industry — process control for concentrations and physical properties
  • Gas treatment — continuous analysis of H2S, ammonia and odorant
  • Food industry — clean-in-place verification through online process analysis

How do we supply Applied Analytics in Romania?

We supply Applied Analytics process analysers based on the manufacturer's technical documentation; availability is confirmed in the quotation, since an instrument this specialised is configured for the application. We bring OMA analysers in to order, usually within 1–4 weeks of the manufacturer's confirmation, depending on the spectral variant and the hazardous-area options required. For a correct quotation, send us the compound to be measured, the expected concentration range, the fluid type (liquid or gas) and whether the installation requires certification for explosive-atmosphere areas.

We check the configuration of each analyser for the application before quoting; availability and lead times are confirmed on the request for quotation.

Frequently asked questions about Applied Analytics

What products does Applied Analytics make?

Applied Analytics makes online process analysers in the OMA range, based on UV-Vis, SW-NIR or InGaAs absorption spectroscopy, for the continuous measurement of chemical concentrations and physical properties in liquid or gaseous process streams.

How do I choose an Applied Analytics analyser by code?

The OMA-300 code indicates the base platform; suffixes (for example InGaAs) indicate the spectral range, and the dedicated names (BTX, NOx, ammonia) indicate the target compound. For selection we need the compound to be measured and the concentration range.

Which variants of the Applied Analytics OMA-300 analyser are available?

The OMA-300 is the wall-mounted version of the platform; there is also the OMA-206p portable version and the OMA-406R rackmount version, the choice depending on the installation space available in your plant.

Do you supply Applied Analytics analysers in Romania, and how long does it take?

We bring them in to order, usually within 1–4 weeks of the manufacturer's confirmation, depending on the spectral configuration and the options for hazardous areas.

What do I need to send for a quotation on an OMA analyser?

The chemical compound to be measured, the expected concentration range, the fluid type (liquid or gas) and whether the installation requires certification for explosive-atmosphere areas, so that the suitable OMA variant can be identified.

How do I request a Applied Analytics quotation?

Send the Applied Analytics code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Applied Analytics Inc. (manufacturer documentation)