Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Brinkmann Brinkmann STA

Brinkmann STA tank-mounted immersion centrifugal pumps, with semi-open impellers, for cooling emulsions and cooling/cutting oils (up to 45 mm²/s, 0…80 °C); maximum discharge pressure 1.1–9.5 bar for STA401–STA1303, for relative density 1.

STA is the Brinkmann series of immersion centrifugal pumps: the impeller is mounted on the extension of the shaft, the pump is fixed above the tank, and the pump part is submerged in the coolant; the maximum liquid level must stay a few mm below the mounting flange. The impellers are semi-open, and the flange has a port for a pressure gauge and can be rotated for horizontal or vertical connection of the pipe. The type code has the form “STA”, the size (for example 901, 1302, 2002) and, after “/”, a number which in the Brinkmann tables corresponds to the immersion depth h in mm (for example STA901/430 has h = 430 mm; for some sizes it differs by a few mm, for example STA602/200 has h = 195 mm); each size is supplied in several depths, listed in the datasheet table. The SAL variants with fast suction have an immersion depth 20 mm greater than the corresponding STA variant (SAL901/220 compared with STA901/200).

For a quotation, send us the full code from the nameplate (the size, the immersion depth and any suffixes), the mains voltage and frequency (50 or 60 Hz), the pumped liquid with its viscosity and temperature and, if the pump replaces an existing one, the immersion depth and the position of the flange on the tank. When the item is in stock, locally or at the supplier, delivery takes 24–72 h; to order, typically 1–4 weeks.

Models and codes

CodeNote
STA603/260Size STA603 is supplied with immersion depths of 260–1,040 mm (8 depths); maximum pressure 3.6 bar, maximum flow 560 l/min; motor 3.3 kW at 50 Hz or 3.8 kW at 60 Hz; H 478 mm; 53–68 kg; 71 dBA at 50 Hz (BE2610).
STA901/200Immersion depths 200–1,100 mm (7 depths); maximum pressure 2.2 bar, maximum flow 930 l/min; motor 3.3 kW at 50 Hz or 3.8 kW at 60 Hz; H 503 mm; 61–95 kg; 71 dBA at 50 Hz (BE2710).
STA902/270Immersion depths 270–1,170 mm (7 depths); maximum pressure 4.3 bar, maximum flow 980 l/min; motor 6.0 kW at 50 Hz or 6.9 kW at 60 Hz; H 574 mm; 98–133 kg; 74 dBA at 50 Hz (BE2710).
STA903/340Immersion depths 340–1,120 mm (6 depths); maximum pressure 6.4 bar, maximum flow 1,050 l/min; motor 9.0 kW at 50 Hz or 10.3 kW at 60 Hz; H 612 mm; 119–149 kg; 74 dBA at 50 Hz (BE2710).
STA904/410Immersion depths 410–1,190 mm (6 depths); maximum pressure 8.6 bar, maximum flow 1,100 l/min; motor 11.0 kW at 50 Hz or 12.6 kW at 60 Hz; H 620 mm; 150–180 kg; 74 dBA at 50 Hz (BE2710).
STA1302/290Immersion depths 290–1,070 mm (6 depths); maximum pressure 4.3 bar, maximum flow 1,600 l/min; motor 7.5 kW at 50 Hz or 8.6 kW at 60 Hz; H 612 mm; 108–137 kg; 74 dBA at 50 Hz (BE2710).
STA2002/410Immersion depths 410–1,160 mm (5 depths); 1,600 l/min at a head of 47 m; motor 22.0 kW at 50 Hz (380–415 V, 40 A, 2,961 rpm) or 26.4 kW at 60 Hz (460 V); H 978 mm; 331–352 kg; 78 dBA (datasheet STA1600…2500).

Key specifications

Immersion depth h (tables STA401–STA1303 and STA2002)120–1.230 mm
Maximum discharge pressure (STA401–STA1303, relative density 1)1.1–9.5 bar
Maximum flow (STA401–STA1303)400–1.620 l/min
Pumped liquidcooling emulsions, coolants and cutting oils, with kinematic viscosity of up to 45 mm²/s
Liquid temperature0…80 (higher temperatures on request) °C
Maximum particle size in the liquid7 mm (STA401–409); 11 mm (STA601–608); 9 mm (STA901–904); 12 mm (STA1001–1004); 14 mm (STA1301–1303)
Motor power (STA401–STA2500)0.85–22 at 50 Hz; 0.98–26.4 at 60 Hz kW
Motor (STA901–STA1303)surface-cooled, IP 55, in line with DIN IEC 34 and EN 60034
Materialscasing and cover in cast iron, shaft in steel; impeller in brass (STA401–409, STA601–608; cast steel optional) or in cast steel (STA901–STA2500)

The operating instructions BE2710 (STA/SAL901…1303) and BE2610 (STA/SAL401…608) are edition 05/2024, 12 pages each; the STA datasheets, including STA1600…2500, are published on the product pages of the “Immersion Pumps” range on the Brinkmann Pumps website, where the series is listed in the “Low Pressure Pumps” category.

Frequently asked questions

How do I read an STA type code, for example STA903/1120?

STA903 is the size, and 1120 corresponds in the table to the immersion depth h = 1,120 mm (for a few sizes, the number in the code differs by a few mm from h, for example STA602/200 has h = 195 mm); in the datasheet table, each size appears with several depths (for STA903: 340, 440, 570, 690, 890 and 1,120 mm). For STA2002, for example, the table lists 410, 540, 660, 910 and 1,160 mm. For a depth that does not appear in the table, we confirm the variant based on the full code from the nameplate.

Is STA a high-pressure pump?

STA is an immersion centrifugal pump, and Brinkmann groups it in the “Low Pressure Pumps” category. The maximum discharge pressures in the STA401–STA1303 tables are 1.1–9.5 bar (relative density 1). For high pressure in coolant systems, the Brinkmann technical information points to screw pumps.

What is the difference between STA and SAL?

SAL is the fast-suction variant of the same pump, for coolants with entrained air. According to the operating instructions, the SAL immersion depth is h + 20 mm, and the mass is 1 kg greater (for example SAL901/220 compared with STA901/200).

Other Brinkmann series

The data come from the STA401–STA1303 tables in the operating instructions BE2610 and BE2710 (edition 05/2024) and from the STA1600…2500 datasheet; for STA3600…4500 we confirm the data by code. For the suffixes after the immersion depth we confirm the exact variant (SAL, motor, voltage, frequency, other designs) based on the full code from the nameplate, before the quotation.

Updated: 2026-11-23