Calpeda Calpeda NM
Calpeda NM (2 poles, ≈ 2,900 rpm) and NM4 (4 poles, ≈ 1,450 rpm) monobloc centrifugal pumps, cast iron, flanged, for clean liquids without abrasives, from -10 °C to +90 °C, with a 0.37–22 kW motor at 50 Hz and a working pressure of up to 16 bar (10 bar for some sizes).
NM and NM4 are Calpeda monobloc centrifugal pumps with flanges, with an electric motor with an extended shaft coupled directly to the pump, with an axial-suction, radial-discharge casing, in cast iron design. NM runs with a 2-pole motor, at ≈ 2,900 rpm (up to 22 kW), and NM4 with a 4-pole motor, at ≈ 1,450 rpm (up to 15 kW), both at 50 Hz. The datasheet also covers related variants of the same range: NMS and NMS4 (a new bracket for standard motors, with integrated thrust bearing), the bronze BNM versions and the EI design, with I-MAT frequency converter. The pumps are intended for clean liquids, without abrasives, not aggressive to the pump materials, with a solids content of up to 0.2%: water supply, heating, air conditioning, cooling and circulation, building and industrial applications, irrigation. The liquid can be from -10 °C to +90 °C, and the total suction lift can reach 7 m.
For a quotation, send us the full code from the pump nameplate (for example NM 32/16A/B or NM4 40/25A/B, with the impeller and revision letters), the mains voltage and frequency, the required flow and head, the temperature and nature of the liquid, and the working pressure of the installation, because the pressure limit differs from one size to another. If the pump has to be replaced, a photo of the nameplate helps us identify the exact variant, including the motor power and the cast iron or bronze design.
Models and codes
| Code | Note |
|---|---|
| NM 32/12F | Code from the 2024 edition of the datasheet; we confirm the revision letter against the current edition. 2 poles; P2 0.55 kW (0.75 HP); current 4 A at 230 V and 2.3 A at 400 V; 13.2 m at zero flow, 7.5 m at 15 m³/h (last value in the table). |
| NM 32/16A/B | Code from the 2024 edition of the datasheet; we confirm the revision letter against the current edition. 2 poles; P2 2.2 kW (3 HP); current 9.2 A at 230 V and 5.3 A at 400 V; 36 m at zero flow, 30.1 m at 16.8 m³/h (last value in the table). |
| NM 40/20B/A | 2 poles; P2 5.5 kW (7.5 HP); current 10.8 A at 400 V and 6.2 A at 690 V; 51 m at zero flow, 30.5 m at 37.8 m³/h (last value in the table). |
| NM 50/12A/C | Code from the 2024 edition of the datasheet; we confirm the revision letter against the current edition. 2 poles; P2 4 kW (5.5 HP); current 9.6 A at 400 V and 5.5 A at 690 V; 24.5 m at zero flow, 10 m at 78 m³/h (last value in the table). |
| NM 65/12A/B | 2 poles; P2 7.5 kW (10 HP); current 14.3 A at 400 V and 8.3 A at 690 V; 25.5 m at zero flow, 17.6 m at 120 m³/h (last value in the table). |
| NM 80/16A/D | Code from the 2024 edition of the datasheet; we confirm the revision letter against the current edition. 2 poles; P2 18.5 kW (25 HP); current 34 A at 400 V and 19.6 A at 690 V; 40 m at zero flow, 28.1 m at 192 m³/h (last value in the table). |
| NM4 40/25A/B | 4 poles; P2 3 kW (4 HP); current 11.1 A at 230 V and 6.4 A at 400 V; 22.8 m at zero flow, 8 m at 30 m³/h (last value in the table). |
| NM4 65/31A/B | 4 poles; P2 9.2 kW (12.5 HP); current 20.5 A at 400 V and 11.8 A at 690 V; 36 m at zero flow, 25 m at 84 m³/h (last value in the table). |
Key specifications
| Maximum flow from the performance tables, by model | NM: 13.2–270; NM4: 10.8–330 m³/h |
|---|---|
| Head at zero flow | NM: 13.2–90; NM4: 5.9–36 m |
| Rated motor power P2 | NM: 0.55–22; NM4: 0.37–15 kW |
| Speed at 50 Hz | NM ≈ 2,900 (2-pole motor); NM4 ≈ 1,450 (4-pole motor) rot/min |
| Liquid temperature | -10…+90 °C; ambient temperature up to 40 °C; total suction lift up to 7 m; continuous duty |
| Maximum working pressure | up to 16 bar; 10 bar for NM 32/12; NM, NM4 32/16 and 32/20; NM, NM4 40/25; NM, NM4 50/20 and 50/25; NM4 65/31; NM, NM4 100/25, for the bronze version and for other sizes listed in the datasheet |
| Motor | three-phase 230/400 V ± 10% up to 3 kW and 400/690 V ± 10% from 4 kW; insulation class F; IP 54; suitable for operation with a frequency converter; IE2 up to 0.65 kW, IE3 from 0.75 kW; single-phase (NMM) up to 1.8 kW, on request |
| Materials | pump casing in cast iron GJL 250 EN 1561 at PN 10 or GJS 400-15 EN 1563 at PN 16; lantern bracket in cast iron GJL 200 EN 1561; impeller in cast iron GJL 200 EN 1561 (brass CW617N EN 12167 at 32/12-16-20 and NM 40/20); shaft in steel 1.4305 EN 10088 (AISI 303), and 1.4104 (AISI 430F) from 3 kW; mechanical seal carbon – ceramic – NBR |
| Connections | flanges PN 10–16, EN 1092-2 (PN 10 at DN 200); discharge port diameter 32–100 mm for NM and 32–125 mm for NM4 |
The values come from the English-language datasheet “NM, NMS” for 50 Hz (62 pages, file created on 20.11.2024), published on the Calpeda website. The “NM, NMS” series page presents the NM, NMS, NM4, NMS4 range and the bronze versions, and currently points to a newer edition of the 50 Hz catalogue (07/25); we therefore confirm the exact code and its values against the current edition before the quotation.
Frequently asked questions
What is the difference between NM, NM4, NMS and the BNM variants?
NM has a 2-pole motor (≈ 2,900 rpm), and NM4 has a 4-pole motor (≈ 1,450 rpm). On NMS and NMS4 the pump has a new bracket for standard motors, with integrated thrust bearing, while on NM and NM4 the motor has an extended shaft, coupled directly to the pump. The letters BNM mark the version with the pump casing and the lantern bracket in bronze CC480K EN 1982, instead of cast iron.
How do I read the code of an NM pump?
The Calpeda datasheet gives the example BNM(S) EI 32/16A/B: B means the bronze version (without B, the cast iron version), NM is the series, S marks the variant with a bracket for a standard motor, EI marks the I-MAT frequency converter, 32 is the discharge port diameter in mm, 16 is the nominal impeller diameter, A is the impeller size, and /B indicates a revision. For a quotation, the full code from the nameplate matters, because power, curve and pressure differ from one model to another.
Are there variants with a single-phase motor or with a frequency converter?
On request, the Calpeda datasheet lists a single-phase motor (NMM) up to 1.8 kW and a design with frequency converter. The EI design has the I-MAT converter mounted on the motor, for powers of 0.37–37 kW, with a control range of 1,750–2,900 rpm at 2 poles and 870–1,750 rpm at 4 poles. We confirm the exact variant before the quotation.
Curves, power, current and pressure limit differ from one size to another; we confirm the full code from the nameplate (including the impeller and revision letters), the cast iron or bronze design and the edition of the Calpeda datasheet before the quotation.
Updated: 2026-11-23