Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

CKD Corporation supplier in Romania

For CKD we quote CMK2 and HCA pneumatic cylinders, 4G and 4F solenoid valves, AD/AP solenoid valves for fluids and W filter-regulators; we need the full code from the component label.

Founded in 1943 · Headquarters: Komaki, Aichi, Japan

Request a quote

Who is CKD Corporation and what does it make?

CKD Corporation makes pneumatic components (cylinders, solenoid valves, air preparation units), fluid control components, electric actuators, direct drive motors, vacuum components and sensors, plus automatic inspection and winding machines for lithium-ion batteries. The company was founded in 1943 and is headquartered in Komaki, Aichi Prefecture, Japan; since 2016 it has had a European office in the Netherlands, at Schiphol-Rijk. For a quotation, send us the full code from the cylinder or the solenoid valve.

CKD pneumatic cylinders cover compact, round-body, tie-rod, flat, rodless, guided, brake or position-lock designs, rotary clamp cylinders and high-durability cylinders. The CMK2 series, with a round body, has bores of φ20–φ40; the HCA series, with tie rods, has bores of φ20–φ100 and speeds of up to 3,000 mm/s; FCD is the flat cylinder, φ25–φ63. The range also includes grippers (hands/chucks) for robots and collaborative robots.

The 3-, 4- and 5-way pneumatic solenoid valves of the 4G series (4GA, 4GB, M4GA) are mounted on the body or on a base plate, while the 4F series covers high flow rates, for cylinders of φ16–φ250. For explosive atmospheres there is the 4GD…EA version with intrinsic safety II 2G Ex ib IIC T4 Gb. The 4GR-T8 solenoid valve blocks connect directly to EtherCAT, PROFINET, EtherNet/IP, IO-Link or CC-Link networks. For compressed air there are the W1000–W8000 filter-regulators (0.5–8.5 bar) and the compact WB500, and for water, air and other fluids, the 2-way pilot-operated solenoid valves AD, ADK, AP and APK, with connections from 1/4" to 2".

What do we supply from the CKD Corporation range?

ProductDescription
CMK2, HCA and FCD Pneumatic CylindersCMK2 is the round-body cylinder of φ20–φ40, with stainless steel variants; HCA is the tie-rod cylinder of φ20–φ100, for speeds of up to 3,000 mm/s; FCD is the rectangular flat cylinder of φ25–φ63, for narrow mounting spaces.
4G and 4F Pneumatic Solenoid Valves3-, 4- and 5-way solenoid valves, with body or base plate connection, mounted individually or in manifold blocks. The 4F series covers high flow rates, for cylinders of up to φ250, and the 4GD…EA version works in an explosive atmosphere with intrinsic safety.
AD, ADK, AP and APK Solenoid Valves for Fluids2-way pilot-operated solenoid valves for water, air and other fluids, with diaphragm (AD, ADK) or piston (AP, APK) operation and connections from 1/4" to 2". The permitted pressure difference reaches 10–12 bar, depending on the series.
W Series Air Preparation UnitsW1000, W2000, W3000, W4000 and W8000 filter-regulators, with 0.5–8.5 bar adjustment and connections from 1/8" to 1", plus filters, lubricators, dryers, pressure switches and flow sensors for the compressed air line.

Why CKD Corporation?

  • Cylinders for several mounting types — compact, round, tie-rod (HCA, up to 3,000 mm/s), rodless, guided or with brake
  • 4GR-T8 solenoid valve blocks with network interface — EtherCAT, PROFINET, EtherNet/IP, IO-Link or CC-Link
  • 4GD…EA explosion-proof version with intrinsic safety II 2G Ex ib IIC T4 Gb, for cylinders of φ20–φ160
  • AD, ADK, AP and APK 2-way pilot-operated solenoid valves for several fluids, with connections from 1/4" to 2"
  • W1000–W8000 filter-regulators with 0.5–8.5 bar adjustment and connections from 1/8" to 1"

Which CKD Corporation codes and series are requested most often?

CodeDescription
CMK2Round-body pneumatic cylinder, φ20–φ40
HCATie-rod cylinder, φ20–φ100, up to 3,000 mm/s
FCDRectangular flat cylinder, φ25–φ63
4GAStandard pneumatic solenoid valve with body connection
4GBStandard pneumatic solenoid valve with base plate connection
4FHigh-flow solenoid valve, cylinders φ16–φ250
4GD…EAExplosion-proof solenoid valve with intrinsic safety
4GR-T8ECSolenoid valve block with EtherCAT interface
W3000Filter-regulator, connections 1/4"–1/2"
WB500Compact filter-regulator, 0.5–7 bar
AD2-way pilot-operated solenoid valve, 1/4"–2"
APK2-way solenoid valve with impulse pilot, piston operation
PV153-way solenoid valve with direct operation
LHBMiniature parallel gripper with linear guide

Where is CKD Corporation equipment used?

  • Machine building and automated lines — cylinders, 4G solenoid valves and grippers
  • Lithium-ion battery manufacturing — automatic winding machines
  • Explosive atmosphere zones — 4GD…EA solenoid valves with intrinsic safety
  • Factory utilities — AD/AP 2-way solenoid valves for water and compressed air
  • Semiconductors — components for high vacuum and specialty gases

How do we supply CKD Corporation in Romania?

We can quote CKD pneumatic cylinders, 4G and 4F solenoid valves, 4GR-T8 network-interface blocks, AD/AP solenoid valves for fluids, W series filter-regulators, vacuum components and spare parts. The CKD code describes the product completely (series, bore, stroke, coil voltage, connections), which is why the code from the component label is the first thing we need. Without a code, send us the bore and stroke of the cylinder or the solenoid valve type and the voltage. We bring in the components on order, typically in 1–4 weeks; 24–72 h when the item is in stock, locally or at the supplier.

We identify old CKD codes on request, from the component label, and propose the current compatible variant; integration into the machine's pneumatic circuit remains the responsibility of the machine builder or of your team.

Frequently asked questions about CKD Corporation

What does CKD Corporation make?

CKD makes pneumatic cylinders, solenoid valves and manifold blocks, air preparation units, solenoid valves for fluids, electric actuators, direct drive motors, vacuum components and sensors, plus automatic inspection and winding machines for lithium-ion batteries. The headquarters is in Komaki, Japan.

How do I choose a CKD solenoid valve for a cylinder?

We start from the cylinder bore and the speed desired: the 4GA1/2/3 series covers cylinders of φ20–φ100, while the 4F series, for high flow rates, goes up to φ250. Then we establish the number of ways, the coil voltage, individual or manifold block mounting and, where applicable, the network interface or the explosion-proof version.

Do you supply CKD components in Romania and in what time?

Yes. CKD components are brought in on order, typically in 1–4 weeks, and items in stock, locally or at the supplier, can leave in 24–72 h. For configured manifold blocks or for explosion-proof versions, depending on the brand and the specifications, the lead time can be longer; the exact lead time appears in the quotation.

I have an old CKD code that no longer appears. What do you do?

Send us the full code and a photo of the label. The code reveals the series, bore, stroke, mounting type and voltage, and on that basis we look for the current variant with the same mounting dimensions. If the label is missing, measure the bore, the stroke and the rod thread.

What do I send for a CKD filter-regulator quotation?

Send the code from the body or, if it is missing, the connection size (from 1/8" to 1"), the regulation pressure required, the air flow rate and the filtration grade desired. The W series filter-regulators adjust between 0.5 and 8.5 bar; for small spaces there is the compact WB500.

How do I request a CKD Corporation quotation?

Send the CKD Corporation code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: CKD Corporation, CKD Europe B.V. (manufacturer documentation)