For DOLD we quote SAFEMASTER safety relays, emergency stop modules such as BD 5935, BH 5928 and RK 5942, standstill and speed monitoring modules such as LH 5946 and UH 5947, safety switches, relays for printed circuit boards and enclosures.
Founded in 1928 · Headquarters: Furtwangen, Germany
Who is DOLD and what does it make?
E. Dold & Söhne, known as DOLD, is a company from Furtwangen, Germany, active since 1928. The programme covers relay modules for safety technology, monitoring devices, power electronics, control devices, time relays, electronics for installations, safety switches with interlock and trapped key systems, relays for printed circuit boards and miniature relays, and enclosures for panels and distribution.
The basic line is SAFEMASTER, made up of safety relays that monitor functions such as emergency stop, two-hand control, pressure-sensitive mats, photoelectric barriers and safety gates. The basic series covers individual functions, SAFEMASTER S monitors standstill and speed of drives, with or without sensors, SAFEMASTER C combines multiple functions in one compact device, SAFEMASTER M is a modular system without software, SAFEMASTER PRO is modular and configurable, and SAFEMASTER W is a wireless safety system.
The emergency stop modules, for example BD 5935, BG 5924, BH 5928 with time delay or RK 5942, only 17.5 mm wide, reach category 4 and PL e according to EN ISO 13849-1, and SIL CL 3 according to IEC/EN 62061 respectively, and the housings come in widths of 17.5, 22.5, 45, 70, 90 or 100 mm. For a quotation, what matters is the full code from the device, the supply voltage, the number of safety contacts and whether time delay or speed monitoring is needed.
What do we supply from the DOLD range?
| Product | Description |
|---|---|
| SAFEMASTER emergency stop modules | Devices for emergency stop and monitoring of safety gates, such as BD 5935, BG 5924, BH 5903, BN 5983 and RK 5942. All reach category 4 and PL e, and most SIL CL 3, in widths from 17.5 to 100 mm. |
| SAFEMASTER S standstill and speed monitoring | Devices for monitoring the standstill and speed of drives: BH 5932 with proximity detectors, LH 5946 and UG 6946 without sensors for motors up to 690 V, UH 5947 with detectors or encoders, UH 6932 and UH 6937. |
| Modules for two-hand control, mats and barriers | The safety programme includes two-hand control modules, modules for pressure-sensitive mats, controllers for photoelectric barriers and monitors for safety gates, all rated up to PL e and SIL 3. |
| Safety switches, relays for printed circuit boards and enclosures | Safety switches with gate interlock and trapped key systems, relays for printed circuit boards and miniature relays, as well as enclosures for panels and distribution, used alongside the safety modules. |
Why DOLD?
- Emergency stop modules with category 4 and PL e — they meet the high safety requirements of automated lines
- Widths from 17.5 mm to 100 mm — the device that fits the existing panel is chosen, without reworking the DIN rail
- Time-delay version BH 5928 and LG 5928 — for controlled stops, where the hazardous movement must end before the supply is cut
- Standstill and speed monitoring, with or without sensors, at 690 V — for drives with frequency converters and large motors
- SAFEMASTER M and PRO modular systems and the SAFEMASTER W wireless version — for installations that need a modular or cable-free solution
Which DOLD codes and series are requested most often?
| Code | Description |
|---|---|
| BD 5935 | Emergency stop module, 45 mm wide, category 4, PL e |
| BD 5987 | Standard emergency stop module, 45 mm wide |
| BG 5924 | Emergency stop module in a 22.5 mm housing |
| BH 5903 | Emergency stop module with voltage drop detection, DC only |
| BH 5928 | Emergency stop module with time delay, 45 mm wide |
| BN 5983 | Emergency stop module in a 100 mm housing |
| RK 5942 | 17.5 mm emergency stop module, DC only |
| BH 5932 | Speed or standstill monitor with proximity detectors, SIL 3 |
| LH 5946 | Sensorless standstill monitor for motors up to 690 V |
| UG 6946 | Sensorless standstill monitor for motors up to 690 V |
| UH 5947 | Speed and standstill monitor with detectors or encoders |
| UH 6937 | Sensorless speed and frequency monitor, for motors up to 690 V |
Where is DOLD equipment used?
- Machine building — emergency stop and monitoring of safety gates
- Automated production lines — two-hand control and photoelectric barriers
- Drives with frequency converters — standstill and speed monitoring
- Lifting equipment and elevators — safety modules for elevator controls
- Electrical panels — safety and monitoring modules mounted on the rail
How do we supply DOLD in Romania?
We can quote DOLD safety relays and modules from the SAFEMASTER lines, monitoring devices, timing devices, safety switches and enclosures. For a correct quotation, send the full code from the device, for example BH 5928 or LH 5946, the supply voltage, the number of safety contacts and the safety function, that is emergency stop, two-hand control or speed monitoring. For replacements, a photo of the nameplate helps. The devices are supplied to order, usually in 1–4 weeks, and they can ship in 24–72 h when the item is in stock, locally or at the supplier; the exact lead time is confirmed in the quotation.
Before the quotation we check the safety function and the category required, and for replacements we compare the old code with the current version of the series, based on the data on the device nameplate.
Frequently asked questions about DOLD
What is a SAFEMASTER safety relay?
It is a device that monitors a safety function, for example the emergency stop button, two-hand control or a safety gate, and commands the stopping of the hazardous movement. DOLD emergency stop modules reach category 4 and PL e according to EN ISO 13849-1.
What is the difference between SAFEMASTER S, C, M, PRO and W?
S monitors standstill and speed of drives, C is compact and multifunctional, M is modular without software, PRO is modular and configurable, and W is a wireless safety system. The basic series covers individual functions. Send the function and the number of inputs.
What frequency range does the SAFEMASTER UH 6937 cover, depending on the variant?
The UH 6937/0 variant accepts input frequencies up to 700 Hz, with a threshold adjustable from 1 to 600 Hz; the /1 variant up to 1200 Hz, threshold 1–1000 Hz. It monitors overfrequency, underfrequency or a window, at 8–280 V AC (single-phase) or 16–690 V AC (single- and three-phase). We confirm the full code with the quotation.
How do I find a replacement for a discontinued DOLD relay?
Send us the full code from the device, for example BH 5928, plus the voltage, the contact type and the housing width. We check the current series with a similar function and tell you whether the terminals and the 22.5, 45 or 100 mm width allow mounting in the same place.
What details do I specify for an LH 5946, UH 5947 or UH 6937 speed monitoring module?
The sensor type (proximity detectors, encoder or sensorless), the motor voltage up to 690 V, the standstill or speed threshold, the supply voltage and the safety level required, for example PL e or SIL 3. Possible models: LH 5946, UH 5947 or UH 6937.
How do I request a DOLD quotation?
Send the DOLD code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: E. Dold & Söhne (manufacturer documentation)