ELMESS supplier in Romania
For ELMESS we quote explosion-proof immersion heaters and cartridge heaters from the DH and DHF series, flow heaters, explosion-proof heating fans and finned-tube room heaters; the item is chosen by medium, power, voltage and Ex zone.
Headquarters: Uelzen, Germany
Who is ELMESS and what does it make?
ELMESS is a German manufacturer of industrial electric heaters, based in Uelzen. The range covers immersion heaters and cartridge heaters with explosion protection, flow heaters for liquids and gases, explosion-proof heating fans and finned-tube room heaters, plus associated temperature controllers and limiters. They are used wherever a liquid, a gas or a room has to be heated in an explosive atmosphere: chemical plants, oil and gas, paint technology, oil stations and tanks.
Immersion heaters are built in several designs. DH..B and DH..C are immersion heaters with a flameproof enclosure (Ex d) or increased safety (Ex de), DH..M is a compact high-power cartridge, and DH..A is a very compact cartridge intended for heating lubricating oil. The DHF type is used for fluids and the DHG type for gases and air. Power reaches approximately 300 kW in the Ex d version and approximately 2 MW without explosion protection, at voltages between 230 and 690 V. The heating bundle is made of stainless steel or of alloys such as Incoloy, and the terminal housing has IP66 protection.
Flow heaters place the immersion heater in a pipe or a vessel and reach temperatures of up to approximately 1000 °C, at nominal pressures between PN 16 and PN 100. The explosion-proof heating fans for rooms are certified for zone 1 under ATEX (the European directive for equipment in explosive atmospheres). For a quotation, what matters is the heated medium, the power, the voltage, the temperature class and the Ex zone.
What do we supply from the ELMESS range?
| Product | Description |
|---|---|
| Immersion and flanged heaters | The DH..B, DH..C, DHF and DHG types heat liquids and gases in vessels, tanks and pipes. The enclosure is flameproof or increased-safety, and the connection is threaded or flanged, from DN 40 up to DN 1200. |
| Explosion-proof cartridge heaters | DH..M is a compact cartridge with a flameproof enclosure (Ex d) and fixed cable, while the very compact DH..A is designed for heating lubricating oil in small compressors, pumps and refrigeration plants. A Pt100 sensor can optionally be fitted for monitoring. |
| Flow heaters | The immersion heater is mounted in a pipe or a vessel for direct heating of thermal oils, water, air and process gases. Power goes up to approximately 300 kW in the Ex d version and up to approximately 4 MW without explosion protection. |
| Explosion-proof heating fans and room heaters | Explosion-proof heating fans heat halls and rooms with power adjusted in steps, and the finned-tube room heaters also come in a version for combustible dust. They are installed in warehouses, containers, crane cabins and instrument rooms. |
Why ELMESS?
- Several designs for the same purpose — the heater is matched to the vessel, the fluid and the installation space
- Ex d and Ex e explosion protection for zones 1, 2, 21 and 22 — the equipment can go into installations with an explosive atmosphere
- The surface loading is set according to the fluid — heavy oil and water call for very different values
- Flow heaters from 0.5 kW to several MW — covering everything from a small gas circuit to a process line
- Controllers and limiters from the same family — the heating circuit can be completed with overtemperature protection
Which ELMESS codes and series are requested most often?
| Code | Description |
|---|---|
| DH..M.. | Compact explosion-proof cartridge heater, Ex d |
| DH..A.. | Very compact cartridge for lubricating oil, Ex de |
| DHF..A0.. | Cartridge with replaceable heating element |
| DH..B.. | Flameproof or increased-safety immersion heater |
| DHF..B.. | Flanged heater, replaceable element |
| DH..C.. | Immersion heater for gases of group II B + H2 |
| DHF | Heater for liquids |
| DHG | Heater for gases and air |
| DHG11B | Heater for motor shutdown periods |
| DST | Explosion-proof temperature controller |
Where is ELMESS equipment used?
- Chemicals and petrochemicals — heating process fluids in areas with explosion hazard
- Oil and gas — heating gas and oil in extraction and distribution installations
- Paints and coatings — heating in spaces with flammable vapours
- Energy and environmental technology — heating natural gas, biogas and process gases
- Machine building — heating lubricating and hydraulic oil
How do we supply ELMESS in Romania?
We can quote ELMESS electric heaters for liquids, gases and rooms, including explosion-proof versions. For a correct quotation, send the medium to be heated, the power or flow rate and the required temperature rise, the supply voltage, the pressure, the Ex zone and the temperature class; if you are replacing an existing item, add the type from the nameplate. We supply the heaters to order, and the usual lead time is 1–4 weeks. Special versions may take longer, and the exact date appears in the quotation.
The Ex zone, the temperature class and the required approvals are set on your request, before the quotation is confirmed.
Frequently asked questions about ELMESS
What does ELMESS make?
ELMESS, based in Uelzen, Germany, makes electric process heaters: immersion heaters, explosion-proof cartridge heaters, flow heaters, gas preheaters, explosion-proof heating fans and room heaters, plus temperature controllers and control panels. The range is aimed at liquids, gases and rooms in areas with explosion hazard.
How is the surface loading of an immersion heater chosen?
The surface loading depends on the fluid: approximately 0.8–1.0 W/cm² for fuel oil, gear oil and bitumen, 1.5–2.3 W/cm² for hydraulic and lubricating oils, 4–8 W/cm² for water. Send the fluid, the temperature and the required power, and we determine the suitable version.
Do you supply ELMESS in Romania, and how quickly?
Yes. ELMESS heaters are ordered through us and usually arrive in 1–4 weeks. An item can ship in 24–72 h when the item is in stock, locally or at the supplier. Special explosion-proof versions may take longer, and the date appears in the quotation.
Can I replace an explosion-proof cartridge heater with another type?
Replacement depends on diameter, length, power, voltage, Ex zone and temperature class. Send the nameplate or the type from the existing cartridge and a photo of the installation, and we check whether a suitable DH or DHF type exists.
What do I need to specify for an explosion-proof heater from the DHF or DHG series?
The DHF series covers heaters for liquids, and DHG heaters for gases and air. For a quotation, send the heated medium, the initial and final temperature, the flow rate or vessel volume, the required power, the voltage, the pressure, the Ex zone, the temperature class and the connection type. For an explosion-proof heating fan, also state the room dimensions.
How do I request a ELMESS quotation?
Send the ELMESS code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: ELMESS Thermosystemtechnik GmbH (manufacturer documentation)