Flygt Flygt ENM-10
Flygt ENM-10 level regulator, a freely suspended electromechanical switch for wastewater pumping stations and groundwater or drainage pumping: standard or Ex version, cable of 6, 13, 20, 30 or 50 m (for the Ex version, 6, 13 or 20 m in the brochure), liquids with a density of 0.95–1.10 g/cm³, 0–60 °C.
Flygt ENM-10 is the tilting-bulb level regulator of the Flygt range, used in wastewater pumping stations and for groundwater or drainage pumping. It does not float on the surface: it hangs freely, submerged in the liquid, and when the level reaches it, the body tilts and the internal microswitch starts or stops a pump or triggers an alarm. It is supplied in a standard version (blue housing) and in an Ex version (black housing, with ATEX and IECEx approvals), with cables of different lengths for liquids with a density between 0.95 and 1.10 g/cm³.
For a quotation, send us the full code from the nameplate of the regulator or of the one being replaced, the version (standard or Ex), the cable length, the liquid density, the role in the installation (start, stop or alarm) and the control circuit voltage. When the item is in stock, locally or at the supplier, delivery takes 24–72 h; to order, typically 1–4 weeks.
Models and codes
| Code | Note |
|---|---|
| ENM-10 standard, 6 m cable | Standard version (blue housing), 6 m cable; liquids with a density of 0.95–1.10 g/cm³. |
| ENM-10 standard, 13 m cable | Standard version, 13 m cable; same density range. |
| ENM-10 standard, 20 m cable | Standard version, 20 m cable. |
| ENM-10 standard, 30 m cable | Standard version, 30 m cable. |
| ENM-10 standard, 50 m cable | Standard version, 50 m cable. |
| ENM-10 Ex, 6, 13 or 20 m cable | Ex version (black housing), ATEX II 1G Ex ia IIC T4 Ga; used with the two-channel Ex safety barrier; not for the North American market. |
Key specifications
| Operating principle | freely hanging electromechanical switch with a microswitch; when the level is reached, the body tilts and closes or opens the circuit |
|---|---|
| Liquid density | 0.95–1.10 (standard version, other densities on request) g/cm³ |
| Liquid temperature | 0–60 °C |
| Degree of protection | IP 68 |
| Cable lengths, standard version | 6, 13, 20, 30 or 50 (other lengths on request) m |
| Cable lengths, Ex version | 6, 13 or 20 (brochure); the manual also lists 30 and 50 m |
| Cable diameter | 6.7 ± 0.2 mm |
| Microswitch breaking capacity (AC) | 250 V / 10 A resistive load; 250 V / 3 A inductive load, cos φ = 0.5 |
| Materials, standard version | polypropylene housing; EPDM rubber bend protection; PVC cable |
| Materials, Ex version | conductive black polypropylene housing; NBR-PVC rubber bend protection and cable |
The installation, operation and maintenance manual “ENM 10 Level switch” (code 899751_16.0, 20 pages) and the brochure “Flygt ENM-10 liquid level regulators” (4 pages, code 1319, edition 20120103) are published on the official Flygt website, and the “Flygt ENM-10 Liquid Level Switch” page on the same site presents the regulator within the level sensor range. The cables, densities, materials and currents come from these two documents; where they differ (for example the cable lengths of the Ex version), both values are given.
Frequently asked questions
What is the difference between the standard and the Ex version?
The standard version has a blue housing, while the Ex version has a black housing made of conductive polypropylene and is marked ATEX II 1G Ex ia IIC T4 Ga and IECEx ia IIC T4 Ga, for ambient temperatures from -20 °C to 60 °C. Ex installations normally require intrinsically safe circuits, and the Ex safety barrier must be installed. The Ex version is not for the North American market.
How many regulators are needed in a station?
The manual calls for two regulators, one for starting and one for stopping, and a third if an alarm is needed at a given level; the same type of regulator can be used for all functions. The brochure gives as an example four regulators in a two-pump station: one at the stop level, one at the start level of each pump and one for the high-level alarm.
What do I send to receive a correct quotation?
The full code from the nameplate, the version (standard or Ex), the cable length, the liquid density, the role of the regulator in the installation and the control circuit voltage. Based on them we confirm the exact code and the availability.
Other Flygt series
The cable length per version, the liquid density and the electrical values are confirmed for the exact code on the nameplate before the quotation; the figures given are those published by Flygt for the ENM-10, and the manual and the brochure differ on some values (Ex cable lengths, direct current).
Updated: 2026-11-23