Genie Filters supplier in Romania
For Genie Filters we quote Genie Supreme 120 and 225 separators, 702, 750 and 755 probes, GR and JTR regulators, Avenger 33 and 38 filters and DaVinci panels; we need the gas composition, the pressure, the temperature and the line connection.
Headquarters: Gonzales, Louisiana, USA
Who is Genie Filters and what does it make?
Genie Filters is the natural gas sample conditioning range made in Gonzales, Louisiana, known for the Genie membrane separators and for the sampling probes with a membrane tip. The role of these components is to stop liquid and particles in the gas sample, so that the analyzer receives only a gas phase that truly represents the sample. We handle the sampling and sample conditioning components: probes, membrane separators, regulators, filters and distribution panels; the analyzers themselves are outside our offer.
The membrane separators of the Genie Supreme series include models 120, 123, 133 and 225, plus Genie 170 for laboratories; model 120 has a membrane section of 1 inch and withstands high pressure in the housing. The probes range from 701 (portable) and 702 (with a permanent insertion, with lengths of up to 10 feet) to 750, 752 and 755 with direct actuation, inserted into and withdrawn from the pressurised line through a full-bore valve. The regulators are GR (single stage, with piston), GHR (heated) and JTR (four-stage Joule-Thomson), with the heated version JTR-H. The JTR corrects the outlet pressure at inlet pressure variations of up to 5,700 PSI.
The range also includes the Avenger 33, 33M, 38, 38M and 91 coalescing filters, the DaVinci panel for distributing the sample to four analyzers and the Humidisorb packs against moisture in housings. Complete ACES systems are designed based on the composition of the flow and the temperature and pressure of the line. A system is sized according to the line conditions and the analyzer it has to protect.
What do we supply from the Genie Filters range?
| Product | Description |
|---|---|
| Genie Supreme 120, 123, 133 and 225 | Membrane separators that retain the liquid and particles carried in the gas sample and let only gas pass to the analyzer. Model 120 is for low flows and high pressures, with a membrane section of 1 inch, and protects chromatographs, mass spectrometers and oxygen or moisture analyzers. |
| Genie probes 701, 702, 750, 752, 755 and 760 | Sampling probes with a membrane tip: 701 is portable, 702 has a permanent insertion with a length of up to 10 feet, 750, 752 and 755 are direct-actuated for natural gas, and 760 is a probe for liquids. They are inserted into the line without a special insertion device. |
| GR, GHR, JTR and JTR-H regulators | GR is a single-stage piston regulator, GHR is the heated version, JTR combines four regulation stages in a single stainless steel housing, and JTR-H is the heated version; the latter prevent sample condensation by compensating for Joule-Thomson cooling. |
| Avenger, DaVinci ADP and Humidisorb | Avenger 33/33M, 38/38M and 91 coalescing and particle filters, the DaVinci panel for distributing the sample to analyzers and Humidisorb packs for controlling moisture and corrosion in housings. |
Why Genie Filters?
- Membrane separators for analyzer protection — Genie Supreme 120, 123, 133 and 225 and Genie 170 for laboratories
- Probes with a membrane tip for pressurised lines — 701, 702, 750, 752, 755 and 760, with insertion and withdrawal through a full-bore valve
- Piston regulators — single-stage GR, heated GHR and four-stage JTR for large variations in inlet pressure
- Avenger 33, 33M, 38, 38M and 91 coalescing filters — versions with or without membrane technology
- DaVinci ADP panel — one inlet sample and up to four low-pressure flows for different analyzers
Which Genie Filters codes and series are requested most often?
| Code | Description |
|---|---|
| Genie Supreme 120 | Membrane separator, low flow, high pressure |
| Genie Supreme 123 | Genie Supreme membrane separator |
| Genie Supreme 133 | Genie Supreme membrane separator |
| Genie Supreme 225 | Genie Supreme membrane separator |
| Genie 170 | Membrane separator for laboratories |
| Genie 702 | Probe with permanent insertion, up to 10 feet |
| Genie 750 | Direct-actuated probe, adjustable length |
| Genie GP2 | Genie GP2 membrane probe |
| Genie GR | Single-stage pressure regulator, with piston |
| Genie GHR | Heated pressure regulator |
| Genie JTR | Four-stage Joule-Thomson regulator |
| Genie JTR-H | Heated Joule-Thomson regulator |
| Avenger 33 | Coalescing and particle filter |
| Avenger 38M | Filter with membrane technology, smaller internal volume |
| DaVinci ADP | Sample distribution panel for four analyzers |
Where is Genie Filters equipment used?
- Natural gas — transmission pipelines and metering stations
- Refineries — sample conditioning for process analyzers
- Petrochemical industry — sampling and conditioning of the gas sample
- Underground gas storage — regulators for large inlet pressure variations
- Analysis laboratories — Genie 170 membrane separators
How do we supply Genie Filters in Romania?
We can quote Genie components for sample conditioning: Supreme separators, 702 and 750 probes, GR and JTR regulators, Avenger filters and DaVinci panels. Supplied to order, usually in 1–4 weeks; depending on the specification, the lead time can be longer for ACES systems designed for the application. For a quotation send the gas composition, the pressure and temperature of the line, the sample flow, the diameter and connection of the line, the insertion length of the probe, the analyzer to be protected and, for a replacement, the model and serial number of the existing part. The final lead time is set in the quotation.
The configuration of a complete conditioning system is established from the composition of the flow and the pressure and temperature of the line, and commissioning at the analyzer is outside our offer.
Frequently asked questions about Genie Filters
What does Genie Filters make?
Genie Filters makes gas sample conditioning components in Gonzales, Louisiana: Genie Supreme membrane separators, probes with a membrane tip, GR, GHR and JTR regulators, Avenger filters, DaVinci panels and ACES systems, all for the protection of gas analyzers.
How do I choose between the Genie 702, 750 and 755 probes?
The 702 probe has a permanent insertion at a fixed depth, with a length of up to 10 feet, while the 750 and 755 are direct-actuated and are inserted into or withdrawn from the pressurised line through a full-bore valve. Send the line pressure, the diameter, the insertion depth and the type of gas.
What lead time do you have for Genie components in Romania?
Parts are supplied to order, usually in 1–4 weeks, and they can ship in 24–72 h when the item is in stock, locally or at the supplier. For ACES systems, designed for the application, the lead time can be longer, depending on the specification; the exact lead time appears in the quotation.
Can I replace an existing membrane separator with a Genie Supreme?
The replacement is confirmed from the data. Send the model and serial number of the current separator, the connection type, the working pressure, the flow and the amount of liquid in the sample; then we check whether a model 120, 123, 133 or 225 fits and what connection adaptations would be needed.
What information do you need to quote a Genie sample conditioning system?
Send the composition of the flow, the pressure and temperature of the line, the sample flow, the protected analyzer, the installation site and whether heating is needed. For a complete ACES system, the configuration is established from these data. Also state the maximum line pressure, for choosing the connection.
How do I request a Genie Filters quotation?
Send the Genie Filters code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Genie Filters (manufacturer documentation)