Gustav Klein supplier in Romania
Industrial UPS, rectifiers and DC sources for safety power supplies
Headquarters: Schongau, Germany
Who is Gustav Klein and what does it make?
Gustav Klein is a German manufacturer of safety power supplies and power electronics, based in Schongau, Bavaria, with a second plant in Inzing, Tyrol. The portfolio includes industrial UPS units, rectifiers, static inverters, frequency converters and DC–DC converters, plus bidirectional DC sources and loads for testing batteries, fuel cells and electric traction chains. For a maintenance engineer, the stake is in equipment that is not seen in the process but that, if it fails, stops the control, the protections or the signalling.
The construction is industrial, not IT-room type. The UPS units of the USV-7011 (single-phase) and USV-7013 (three-phase) series are class VFI-SS-11 under IEC 62040-3, cover 10–200 kVA single-phase and 10–500 kVA three-phase, work with intermediate battery voltages of 110, 220 or 372 V DC and are supplied with spare parts for at least 15 years. The battery can be tested by feeding the energy back into the grid, without an artificial load. For testing, the liquid-cooled I-TS-3872 source/load reaches 1500 V DC and 2000 A, and the I-TS-3873 is installed in parallel up to 5 MW.
The equipment is used where the auxiliary DC or AC voltage must not be interrupted: substations and power plants, chemical and petrochemical installations, railway signalling infrastructure, maintenance workshops for rolling stock. When replacing an old rectifier or UPS, the data on the nameplate matter: the type, the rated power, the battery voltage and the output configuration.
What do we supply from the Gustav Klein range?
| Product | Description |
|---|---|
| USV-7011 / USV-7013 — industrial UPS | Static UPS units with a regenerative IGBT rectifier, a PWM-technique IGBT inverter, galvanic isolation at the output, and electronic and manual bypass. Rated power 10–200 kVA single-phase and 10–500 kVA three-phase, colour TFT display with event memory and SNMP or Modbus interfaces. |
| GR-3811 / GR-3812 / GR-3864 — Industrial rectifiers | Rectifiers for DC supplies together with the battery: the GR-3811 and GR-3812 in thyristor technology, the GR-3864 with IGBT and pulse-width modulation. They are complemented by GR-5713 (single-phase) and GR-5701 (three-phase) rectifier modules for lower powers and combined supplies. |
| I-TS-3872 / I-TS-3873 — DC sources and loads | Bidirectional systems for testing batteries, fuel cells and traction chains. The I-TS-3872 has liquid cooling, up to 1500 V DC and 2000 A, including the SiC version; the I-TS-3873 reaches 5 MW in parallel, for battery containers and electrolysis. |
| Power supplies for railways and urban transport | Combinations of UPS, rectifiers, inverters and frequency converters for railway control and safety installations, built to the rules of the network operator, plus frequency converters for 16.7 Hz networks. |
Why Gustav Klein?
- Class VFI-SS-11 under IEC 62040-3 on the USV-7011/7013 — output independent of grid variations, with 0 ms interruption time, suited to critical loads
- Spare parts available for at least 15 years — this matters in installations with a service life of decades, where full replacement is postponed
- Battery test by feeding back into the grid — discharge at high power without a separate resistive load, with low net consumption
- Intermediate battery voltages of 110, 220 or 372 V DC — they match the usual DC busbars in substations, power plants and process installations
- DC sources and loads from a single channel up to 5 MW in parallel (I-TS-3873) — the same family covers a laboratory bench and tests on battery containers
Which Gustav Klein codes and series are requested most often?
| Code | Description |
|---|---|
| USV-7001 | Single-phase thyristor UPS, optional version |
| USV-7003 | Three-phase thyristor UPS, optional version |
| USV-7011 | Single-phase IGBT UPS, 10–200 kVA |
| USV-7013 | Three-phase IGBT UPS, 10–500 kVA |
| GR-3811 | Industrial thyristor rectifier |
| GR-3812 | Industrial thyristor rectifier |
| GR-3864 | IGBT rectifier with pulse-width modulation |
| GR-5713 | Single-phase rectifier module |
| GR-5701 | Three-phase rectifier module |
| I-TS-3840 | DC source/load, single channel, standard version |
| I-TS-3842 | DC source/load, single channel, with overload capacity |
| I-TS-3870 | DC source/load, single channel, configurable |
| MI-TS-3871 | DC source/load with 2 or 4 channels |
| I-TS-3872 | Liquid-cooled DC source/load, up to 1500 V and 2000 A |
| I-TS-3873 | High-power DC source/load, up to 5 MW in parallel |
Where is Gustav Klein equipment used?
- Electric power — DC supplies and UPS for control and protections in substations and power plants
- Chemicals and petrochemicals — industrial UPS for control systems that do not allow interruptions
- Railway — power supply for safety installations and 16.7 Hz converters
- Battery laboratories and e-mobility — bidirectional sources and loads for cells, modules and containers
- Telecommunications — safety power supply systems for critical nodes
How do we supply Gustav Klein in Romania?
We can quote Gustav Klein industrial UPS units, rectifiers and modules, especially for replacing installations that are already fitted. The equipment is supplied to order, usually in 1–4 weeks; for systems configured for a project the lead time can be longer and is stated in the quotation. For a correct quotation, it helps us to have the type and series from the nameplate (for example USV-7013 or GR-3864), the rated power, the grid and battery voltage, the type of accumulators and any options fitted. For old installations, a photo of the nameplate and the principle diagram shorten the check.
Options or subassemblies withdrawn from production are checked once the exact configuration has been established.
Frequently asked questions about Gustav Klein
What product range does Gustav Klein have?
Gustav Klein, based in Schongau in Germany, makes industrial UPS units, rectifiers, static inverters and frequency converters for safety power supplies, plus DC sources and loads for testing batteries and fuel cells. A second production site operates in Inzing, in Austria.
How do I size an industrial USV-7013 UPS?
You start from the power of the loads in kVA, the grid voltage and the autonomy wanted, which determines the battery. The USV-7013 series covers 10–500 kVA three-phase, with an intermediate voltage of 110, 220 or 372 V DC. If you are replacing existing equipment, the data on its nameplate are enough for a first calculation.
How long does it take to receive a Gustav Klein UPS or rectifier in Romania?
Gustav Klein equipment is supplied to order, usually in 1–4 weeks. For configured or high-power systems the lead time can be longer, and the exact value is confirmed in the quotation, after the configuration has been checked.
Can I replace a GR-3811 rectifier with a new model from the range?
It depends on the rated power, the output voltage, the battery type and the cabinet dimensions. Equivalence is established after checking: send the nameplate of the old rectifier and the connection diagram, and we establish which current version fits.
What data should I send for a quotation on an I-TS DC source?
The voltage and maximum current are needed, whether the application requires only a source or also a regenerative load, the number of channels, the type of cell or battery tested and the cooling available. On this basis we establish whether the I-TS-3840, I-TS-3872 or a configurable series fits.
How do I request a Gustav Klein quotation?
Send the Gustav Klein code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Gustav Klein GmbH & Co. KG (manufacturer documentation)