Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Halifax Fan supplier in Romania

For Halifax Fan we quote industrial centrifugal fans, ATEX fans, straight-blade fans, DIDW, bifurcated axial and plenum fans, plus control dampers; flow, pressure, temperature and the Ex zone matter.

Headquarters: Brighouse, United Kingdom

Request a quote

Who is Halifax Fan and what does it make?

Halifax Fan is a British manufacturer of industrial centrifugal fans, based in Brighouse. The range covers centrifugal fans, fans for explosion-hazard areas (ATEX), straight-blade fans, double-inlet DIDW fans, axial and bifurcated axial fans, plenum fans, plastic fans and control dampers, plus bearing units and repair services. They are fitted for combustion air, forced draught, dryers, dust and fume control, venting and building ventilation.

Straight-blade fans are made for large quantities of product or dust, with an easy-to-clean rotor, with variants for conveying chips or aluminium cans, with wear plates for abrasive wear and with crevice-free designs for food and pharmaceutical use. DIDW fans give the same pressure rise as a single-inlet fan, but twice the flow, with a single motor. Plenum fans are centrifugal rotors without a casing, with diameters between 315 and 2000 mm, for temperatures from −40 °C to over 500 °C.

Bifurcated axial fans have the motor outside the airflow, which allows them to handle steam, fumes or gases harmful to a standard motor; in the standard version they work up to 105 °C, and with a lined motor compartment up to 205 °C. ATEX versions are made according to Directive 2014/34/EU, with IECEx. For a quotation, what matters is the operating data of the installation and the Ex zone.

What do we supply from the Halifax Fan range?

ProductDescription
Industrial centrifugal fansFans for combustion air, forced draught, dryers, dust and fume control. They include high energy efficiency variants, with a steel or stainless steel rotor, in sizes and materials set according to the operating data.
Straight-blade fans and DIDWThe straight-blade rotor is designed for large quantities of dust and product, and ORB (Open Radial Blower) has narrow blades and a full backplate for higher pressures. DIDW is made in carbon steel or stainless steel, with direct or belt drive.
Bifurcated axial and plenum fansBifurcated axial fans have the motor separated from the flow and exist in versions for normal or high temperature, in galvanised steel or stainless steel, including ATEX. Plenum is a centrifugal rotor without a casing, for high flows in multiple directions.
ATEX fans and control dampersDesigns for explosion-hazard areas, with a gas-tight casing, flame arrestors and special shaft seals. The dampers are opposed-blade, butterfly, inlet-vane or circular types, for flow control.

Why Halifax Fan?

  • Straight-blade fans for dust and product — the rotor is easy to clean and can be fitted with wear plates
  • Double-inlet DIDW — doubles the flow at the same pressure rise, with a single motor
  • Bifurcated axial fans with the motor outside the airflow — used for steam, fumes and gases that would damage a standard motor
  • Plenum from 315 to 2000 mm and from −40 °C to over 500 °C — suited to air handling units and filtration installations
  • ATEX versions with gas-tight construction — make installation possible in areas with an explosive atmosphere

Which Halifax Fan codes and series are requested most often?

CodeDescription
DIDWDouble-inlet centrifugal fan
ORBOpen Radial Blower, narrow blades and back plate
Paddle bladeCentrifugal fan with straight blades
PlenumCentrifugal rotor without casing, 315–2000 mm
Bifurcated axialAxial fan with motor outside the airflow
ATEX centrifugalCentrifugal fan for Ex zones
Plastic fanPlastic fan for corrosive environments
Inlet vaneDamper with inlet vanes
Butterfly damperButterfly damper for isolation
Louvre damperDamper with opposed blades

Where is Halifax Fan equipment used?

  • Chemicals and petrochemicals — ATEX fans for gases and vapours
  • Energy and power plants — combustion air and forced draught
  • Food and beverage industry — fans in hygienic design
  • Metals, glass and paper — dust and fume control
  • Marine and offshore — plenum and ATEX fans for difficult environments

How do we supply Halifax Fan in Romania?

We can quote Halifax Fan centrifugal, bifurcated axial, plenum, DIDW and ATEX fans, as well as control dampers and spare parts. For a correct quotation, send the nameplate of the existing fan or, for a new installation, the flow, the pressure, the temperature, the nature of the air or gas, the Ex zone and temperature class, and the motor voltage. Supply is to order, usually in 1–4 weeks. Special designs can need more time, and the exact date is given in the quotation.

The rotor, the material and the seals are confirmed in the quotation, based on the operating data of the installation and the nature of the gas.

Frequently asked questions about Halifax Fan

What are the DIDW, ORB, plenum and bifurcated axial fans at Halifax Fan?

DIDW is a double-inlet centrifugal fan, and ORB is the Open Radial Blower version. Halifax Fan, based in Brighouse in the United Kingdom, makes industrial centrifugal fans, ATEX fans, straight-blade, DIDW, bifurcated axial, plenum and plastic fans, plus dampers and bearing units. They are used for combustion air, forced draught, dryers, dust control and ventilation.

When is a bifurcated axial fan chosen?

A bifurcated axial fan is chosen when the air contains steam, fumes or gases that would affect a motor in the flow, because the motor is outside the air. The standard version works up to 105 °C, and with a lined motor compartment up to 205 °C. Send the temperature and the flow.

Do you supply Halifax Fan in Romania, and how fast?

Yes. Halifax Fan is supplied to order, usually in 1–4 weeks. Items can ship in 24–72 h when the item is in stock, locally or at the supplier. For special designs the lead time can be longer, and the date is given in the quotation.

Can I replace an existing centrifugal fan?

It can be checked if you send the nameplate, the casing size, the rotor diameter, the flow and the pressure, the direction of rotation, the drive type and the position of the discharge outlet. Compatibility is established only after comparing the data, and the conclusion is given in the quotation.

What data do you need for an ATEX fan?

For an ATEX fan, send the zone (for example zone 1), the gas group and the temperature class, the flow, the pressure, the temperature and the nature of the gas, the motor voltage and the material wanted for the casing and the rotor. On this basis the design is set in the quotation.

How do I request a Halifax Fan quotation?

Send the Halifax Fan code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: Halifax Fan Ltd (manufacturer documentation)