Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Heatex supplier in Romania

Air-to-air heat recovery exchangers: plate, counterflow and rotary

Headquarters: Malmö, Sweden

Request a quote

Who is Heatex and what does it make?

Heatex is a Swedish manufacturer of air-to-air heat recovery exchangers, based in Malmö, that makes products to order, to each customer's technical specifications. The company specialises in heat transfer between two air streams. The main buyers are air handling unit manufacturers, who fit the Heatex exchanger inside the unit for heat recovery or for humidity control between fresh and exhaust air.

The range is divided into three families. Crossflow exchangers have aluminium plates, extruded corner profiles (optionally stainless steel), double sealing by bonding and mechanical folding, and transfer up to 90% of the heat of the exhaust air. Counterflow ones include Model M, a lightweight version for enclosure cooling, used in telecommunications equipment and inverters. Rotary exchangers (heat wheels) exist with a monobloc or segmented rotor, in models E, ES, EN, EQ, ER and O, with diameters in 1 mm steps.

The main interest is replacing a recovery block in an existing unit or sizing an exchanger for a process with hot and humid air, such as dryers or paint booths. The products carry Eurovent and AHRI certifications, and performance calculations are made with Heatex's in-house program, Heatex Select. For a quotation, the interior dimensions of the unit, the air flow rates, the temperatures and the old model matter, because the block is built to these data.

What do we supply from the Heatex range?

ProductDescription
Crossflow exchangers, Model H2 and other modelsAluminium plate blocks for heat recovery between exhaust and fresh air, with up to 90% heat transfer. Dimensions are chosen between 200 and 3000 mm, with anticorrosion protection options and bypass dampers.
Counterflow exchangers, Model MCompact, lightweight exchanger built in a double L, double U or L+U configuration, for cooling enclosures with electronics, in telecommunications and in inverters. The declared sensible efficiency approaches 90% in dry operation.
Rotary exchangers (heat wheels)Wheels with a heat and moisture transfer matrix, monobloc or segmented, with efficiency between 70% and 90%. There are models with a housing (E, ES, EN) and without a housing (O, ER), plus a Marine Edition rotor on request.
Solutions for electronics cooling and industrial ventilationThe same exchanger families adapted for wind turbines, data centres, charging stations for electric vehicles, industrial drying and paint booths.

Why Heatex?

  • Products made to order — dimensions and performance fit the existing unit, not the other way round
  • Crossflow exchangers with double sealing (bonding and mechanical folding) — reduces leakage and contamination between streams
  • Heat wheels with diameters in 1 mm steps and housings made to size — useful for replacements in units with fixed space
  • Model H2 tested to IP65 according to EN 60529 at RISE — a version for environments with high humidity or exposure to water
  • Eurovent, AHRI and HYG certifications declared for plate and rotary exchangers — documents useful for acceptance and technical files

Which Heatex codes and series are requested most often?

CodeDescription
Model H2Crossflow plate exchanger, tested to IP65 according to EN 60529
Model MCounterflow exchanger for enclosure cooling
Model ERotary exchanger with housing, for medium flow rates, with Model O wheel
Model ESRotary exchanger with segmented housing, for high flow rates, with Model ER wheel
Model ENRotary exchanger for low flow rates, with reduced-diameter hub and bearing
Model EQRotary exchanger version with its own installation and maintenance instructions
Model OMonobloc heat wheel, without housing
Model ERSegmented heat wheel, without housing
Marine EditionRotor for marine applications, on request
Heatex SelectProduct performance calculation program, with approvals according to the manufacturer's documentation

Where is Heatex equipment used?

  • Commercial ventilation — recovery exchangers in air handling units
  • Industrial ventilation — paint booths, drying, industrial dehumidification
  • Naval and offshore — Marine Edition rotor for onboard ventilation
  • Wind energy and power electronics — cooling of the nacelle, inverters and converters
  • Telecommunications and data centres — enclosure cooling with filtered air

How do we supply Heatex in Romania?

We can quote Heatex exchangers for replacing a recovery block or for a new unit, starting from the dimensions and air parameters of the installation. Supplied to order; as these are products built to specification, the lead time may be longer than for standard items, and the exact lead time is confirmed in the quotation. For checking we need the length, width and thickness of the block, the air flow rates, the temperatures and humidity of the two streams, the material wanted and, for wheels, the diameter and housing type.

The performance of an exchanger for a specific case is established through the factory's calculation on the air data, and compatibility with an old unit is checked on dimensions.

Frequently asked questions about Heatex

What products does Heatex make?

Heatex makes air-to-air heat exchangers to order: crossflow or counterflow plate blocks and heat wheels (rotary). They are used in air handling units, in industrial ventilation and for cooling enclosures with electronics. The company is based in Malmö, Sweden.

How do I choose between a plate exchanger and a heat wheel?

The plate exchanger has no moving parts and separates the streams completely, while the heat wheel also transfers moisture and has a lower risk of freezing. The choice depends on the air flow rate, the need for moisture recovery and the space in the unit; for an accurate quotation we need these data.

Do you supply Heatex products in Romania, and in how long?

Yes, supplied to order. As these are products configured to specification, the order lead time usually starts from 1–4 weeks and may be longer; we confirm it in the quotation.

Can I replace an old recovery block with a Heatex one?

In many cases yes, but the block is built to the interior dimensions of the unit. Send us the length, width, thickness and orientation of the old block, plus a photo of the nameplate or of the plates, so that we can check which model fits.

What details should I send for a quotation on a Heatex exchanger?

Send the air flow rates and temperatures for the exhaust and fresh streams, the humidity, the dimensions of the available space, the material wanted (aluminium, stainless steel) and the working environment. For wheels, add the diameter and housing type.

How do I request a Heatex quotation?

Send the Heatex code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 22 November 2026 · Sources: Heatex AB (manufacturer documentation)