Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

HEXONIC supplier in Romania

For HEXONIC we quote JAG F, F and MULTISECTION gasketed plate heat exchangers, L, Luna, R, SafePLATE, AS and L ULTRA brazed exchangers, DNA shell-and-tube exchangers and JAD and S shell-and-coil exchangers; the item is identified by series and fluids.

Founded in 1988 · Headquarters: Nowy Dwór Gdański, Poland

Request a quote

Who is HEXONIC and what does it make?

HEXONIC is a heat exchanger manufacturer headquartered in Nowy Dwór Gdański, Poland, active since 1988. The range includes gasketed plate heat exchangers, brazed plate heat exchangers, shell-and-tube exchangers, shell-and-coil exchangers, plate-and-shell exchangers, dry coolers and custom-built heat exchangers. Applications range from heating and refrigeration installations to the food, pharmaceutical, energy and chemical industries and data centres.

Among gasketed plate heat exchangers, the JAG F series is the demountable version, with a corrugation that increases turbulence and limits fouling. The unit opens for cleaning and can take additional plates, and optionally has a double-wall system for rapid leak detection. The plates are made of 304L, 316L or 254SMO stainless steel, of Hastelloy C-276 or of titanium, and the gaskets of NBR, EPDM or FKM. The design pressure reaches 30 bar and the temperature 170 °C. The F series is the general solution for industrial services and utilities, and MULTISECTION is the stainless steel version for pasteurisation and food processes.

Brazed exchangers are divided into series: L for liquid-to-liquid, Luna in all-stainless steel for sanitary requirements, R for refrigeration evaporators and condensers, SafePLATE with a double wall, AS asymmetric for heating and L ULTRA for high pressures, including CO2 applications. DNA is a shell-and-tube exchanger with helical 316L stainless steel tubes. For a quotation, what matters is the fluids, the flow rates, the inlet and outlet temperatures, the working pressure and the connection type.

What do we supply from the HEXONIC range?

ProductDescription
JAG F gasketed plate heat exchangersA demountable exchanger with JAG corrugation, used in HVAC, refrigeration, the food and energy industries and data centres. Flanged connections range from DN80 to DN350, the design pressure is 30 bar, and a double-wall system is available as an option.
F and MULTISECTION seriesThe F series covers industrial services and utilities with a configurable plate pack and easy servicing. MULTISECTION is a stainless steel exchanger for pasteurisation, milk, beer, sugar and CIP stations, with a hybrid gasket fixing system and certified gaskets.
Brazed exchangers L, Luna, R, SafePLATE, AS and L ULTRAThe L series is the standard for liquid-to-liquid, Luna is all stainless steel, R works as an evaporator or condenser, SafePLATE has a double wall, AS is asymmetric for heating, and L ULTRA withstands high pressures for cooling and heating with CO2.
DNA shell-and-tube exchangers and JAD and S shell-and-coil exchangersDNA has 10 mm helical tubes in 316L stainless steel, a design pressure of 10 bar on the shell and 16 bar on the tubes, at a maximum of 200 °C. JAD and S are compact exchangers with a coil in the shell, for heating, refrigeration and processes.

Why HEXONIC?

  • Demountable plates on JAG F — the unit can be cleaned and extended, useful when the heat load grows after commissioning
  • Stainless steel, Hastelloy or titanium plates and NBR, EPDM or FKM gaskets — the materials match the fluid in the circuit, from water to oil and salt water
  • Optional double wall on JAG F and on the SafePLATE brazed series — for installations where mixing of the fluids must be avoided
  • The AS series is asymmetric, designed for heating, with a design pressure of 25 bar and a temperature of 230 °C — low pressure drop on the secondary circuit in central heating systems
  • Helical tubes on DNA — the turbulent flow in the tubes gives good heat transfer even with viscous media

Which HEXONIC codes and series are requested most often?

CodeDescription
JAG FDemountable gasketed plate heat exchanger, with JAG corrugation and double-wall option
FGasketed plate heat exchanger for general industrial services and utilities
MULTISECTIONStainless steel plate heat exchanger for pasteurisation and food processes
LStandard brazed exchanger for liquid-to-liquid
LunaAll-stainless steel brazed exchanger for high sanitary requirements
RBrazed exchanger for refrigeration evaporators and condensers
SafePLATEDouble-wall brazed exchanger, for separating fluids
ASAsymmetric brazed exchanger for heating, up to 25 bar and 230°C
L ULTRABrazed exchanger for high pressures, used with CO2
DNAShell-and-tube exchanger with helical 316L stainless steel tubes
JADShell-and-coil exchanger for heavy duty
SCompact shell-and-coil exchanger for low-power systems

Where is HEXONIC equipment used?

  • HVAC and refrigeration — heating, cooling, heat recovery, commercial refrigeration installations and heat pumps
  • Food industry — pasteurisation, beer, dairy, oil, sugar and CIP stations
  • Energy — ORC installations and lubricating oil coolers
  • Chemicals, petrochemicals and refining — process cooling and heating
  • Data centres — free cooling, CDU units and immersion cooling

How do we supply HEXONIC in Romania?

We can quote HEXONIC gasketed, brazed, shell-and-tube and shell-and-coil heat exchangers, as well as replacement plates and gaskets for existing units. For a correct quotation, send the series and the number from the exchanger nameplate, the fluids in both circuits, the flow rates, the inlet and outlet temperatures, the working pressure and the connection type. When replacing plates or gaskets, the number of plates and the current material help us. The equipment is brought in to order, usually in 1–4 weeks, and depending on the series and the specification the lead time can be longer. The exact lead time is confirmed in the quotation.

For large units or units in special materials, such as Hastelloy or titanium, we set the exact combination of plates and gaskets in the quotation, based on the process data you provide.

Frequently asked questions about HEXONIC

What types of heat exchangers are in the HEXONIC range?

HEXONIC makes gasketed plate heat exchangers (JAG F, F, MULTISECTION), brazed plate heat exchangers, shell-and-tube (DNA), shell-and-coil (JAD, S), plate-and-shell, dry coolers and custom-built heat exchangers. The headquarters is in Nowy Dwór Gdański, Poland.

When do I choose a demountable exchanger and when a brazed one?

A demountable unit, for example JAG F, opens for cleaning and can take extra plates, so it suits fluids that leave deposits or loads that grow over time. The brazed one is closed by brazing and is chosen for clean circuits. Send the fluids and the temperatures.

What pressure, temperature and plates does the HEXONIC JAG F exchanger have?

JAG F is designed for up to 30 bar and 170 °C. Threaded connections range from G1¼″ to G2″, flanged ones from DN80 to DN350. Plates are made of stainless steel 304L, 316L or 254SMO, Hastelloy C276 or titanium Gr.1. We confirm the exact variant with the quotation.

Can I order replacement plates or gaskets for an already installed HEXONIC exchanger?

Yes, if we identify the series. We need the name and series from the exchanger nameplate, the number of plates, the gasket material (NBR, EPDM or FKM) and the plate material. With these details we prepare the quotation for the suitable spare parts.

What details do I send for a quotation on a HEXONIC exchanger?

The fluid in each circuit, the flow rates, the inlet and outlet temperatures, the maximum pressure, the thermal output wanted and the connection type. For JAG F it also matters whether a double wall is needed, and for DNA, whether flue gas, hot air or low-pressure steam flows on the shell side.

How do I request a HEXONIC quotation?

Send the HEXONIC code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote