HOMA Pumpenfabrik HOMA Barracuda GRP
HOMA Barracuda GRP submersible pumps with cutting device, in EN-GJL-250 cast iron, for dirty water and wastewater with solids, fibres and faecal matter: GRP16–GRP50 with G2 connection and 1.3–5.2 kW, GRP56–GRP111 with DN 50 connection and 7.5–11.0 kW.
Barracuda GRP is the HOMA series of submersible pumps with a cutting device fitted ahead of the impeller, which shreds the solids in the medium, so that plastic pipes with sections from 1½" (GRP16–50), or from DN 50 (GRP56–111), are sufficient for the piping. The series is used for removing wastewater through small pipe sections, at high discharge heads and relatively low flow. The pumped medium is clean or dirty water, wastewater loaded with solids and fibres and faecal matter, at a maximum temperature of 40 °C, briefly up to 60 °C. The pump casing, motor housing and impeller are in EN-GJL-250 cast iron, and the cutting device is in 1.4122 stainless steel. The motor is fully submersible, insulation class H, IP 68, with a thermal sensor in the winding. All types are also supplied in the explosion-proof version to ATEX 2014/34/EU.
For a quotation, send us the full code from the pump's nameplate (for example GRP 26 D or GRP 50 D (Ex)), the supply voltage, whether an automatic float switch (A), an Ex version or an ET motor is needed, and the installation method (stationary with coupling system or portable). When the item is in stock, locally or at the supplier, delivery takes 24–72 h; to order, typically 1–4 weeks.
Models and codes
| Code | Note |
|---|---|
| GRP 16 (B) W (A) (Ex) | 1.5 kW (P1) / 1.1 kW (P2), 230 V single-phase, 2,900 rpm, 7.5 A, capacitor 30/60 µF, 27 kg. |
| GRP 16 (B) D (A) (Ex) | 1.3 kW (P1) / 0.9 kW (P2), 400 V three-phase, 2,900 rpm, 2.5 A, 27 kg. |
| GRP 26 D (A) (Ex) | 2.5 kW (P1) / 1.9 kW (P2), 400 V three-phase, 2,900 rpm, 4.4 A, 33 kg. |
| GRP 36 D (A) (Ex) | 3.7 kW (P1) / 3.1 kW (P2), 400 V three-phase, 2,900 rpm, 6.4 A, 44 kg; the GRP 36 HD (A) (Ex) version has the same power, current and weight values. |
| GRP 50 D (Ex) | 5.2 kW (P1) / 4.4 kW (P2), 400 V three-phase, 2,840 rpm, 8.7 A, 56 kg; star-delta starting. |
| GRP 76 (ET)D(Ex) | 7.5 kW (P1) / 6.4 kW (P2), 400 V three-phase, 2,900 rpm, 13.0 A, DN 50 connection; 104 kg for wet installation and 108 kg for dry installation. |
| GRP 111 (ET)D(Ex) | 11.0 kW (P1) / 9.5 kW (P2), 400 V three-phase, 2,900 rpm, 18.8 A, DN 50 connection; 107 kg for wet installation and 111 kg for dry installation. |
Key specifications
| Discharge connection | G2 (DN 50) on GRP16–GRP50; DN 50 on GRP56–GRP111 |
|---|---|
| Motor power P1 | 1.3–5.2 (GRP16–GRP50); 7.5–11.0 (GRP56–GRP111) kW |
| Motor power P2 | 0.9–4.4 (GRP16–GRP50); 6.4–9.5 (GRP56–GRP111) kW |
| Maximum discharge head (Hmax) | 20.4–52.0 (GRP16–GRP50); 42.0–68.0 (GRP56–GRP111), according to the series pages m |
| Maximum flow (Qmax) | 11.7–27.7 (GRP16–GRP50); 30.7 (GRP56–GRP111), according to the series pages m³/h |
| Pump weight | 27–56 (GRP16–GRP50); 104–107 for wet installation and 108–111 for dry installation (GRP56–GRP111, without the ET version) kg |
| Materials | Pump casing, motor housing and impeller in EN-GJL-250 cast iron; motor shaft and bolts in stainless steel; cutting device in 1.4122 stainless steel; silicon carbide mechanical seal; NBR elastomers |
| Medium temperature | max. 40; briefly up to 60 °C |
| Motor and starting | Fully submersible, insulation class H, IP 68, thermal sensor in the winding; direct starting on GRP16–36, star-delta on GRP44–50 and GRP56–111 |
The GRP16–50 data sheet (code 0.0/0826) and the GRP56–111 data sheet (code 0.0/0923) are published on the Barracuda GRP16–GRP50 and GRP56–GRP111 series pages of the HOMA website, alongside the operating instructions.
Frequently asked questions
What do the letters in the pump code mean, for example GRP 26 D or GRP 16 W?
The GRP16–50 data sheet explains: W means the 230 V single-phase 50 Hz version, D means 400 V three-phase 50 Hz, A means with HOMA-Nivomatik automatic float switch, Ex means explosionsgeschützt (explosion-proof) and B (on GRP 16 B) means with support feet. The GRP56–111 data sheet explains: ET means EffTec motor with PermaCool® permanent cooling for wet and dry installation, and Ex means explosion-proof.
Are there GRP pumps in the explosion-proof version?
Yes. Both data sheets state that all types are also supplied in the explosion-proof version to ATEX 2014/34/EU; the GRP16–50 data sheet indicates for the Ex version a relay for an intrinsically safe control circuit. We confirm the marking and the zone for the exact code before quotation.
What is the difference between GRP16–50 and GRP56–111?
The GRP16–50 have a G2 discharge connection, P1 power of 1.3–5.2 kW, are also available in a single-phase version (W, on GRP16, GRP20 and GRP26) and, from GRP20, have two mechanical seals, with electronic seal monitoring on request; the GRP56–111 have a DN 50 connection, P1 power of 7.5–11.0 kW, are three-phase only, with star-delta starting, and have two independent mechanical seals, with electronic seal monitoring as standard.
Other HOMA Pumpenfabrik series
The performance curves, installation dimensions and versions (W/D, A, Ex, ET) are read from the data sheet for the exact type; we confirm the full code from the nameplate before quotation.