Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Kistler-Morse supplier in Romania

Microcell sensors for vessel weighing, LD3 cells, SVS2000 controller

Founded in 1974

Request a quote

Who is Kistler-Morse and what does it make?

Kistler-Morse was founded in 1974 in Bellevue, Washington, starting from a quartz pressure gauge that became the bolt-on Microcell sensor. The company later moved to South Carolina. The current lines are sensors, controllers and inventory management.

The idea behind Kistler-Morse is to weigh a vessel without lifting it. The Microcell Bolt-On sensor is fixed to the wall or leg of a vessel and turns the deformation of the structure into a signal proportional to weight. The L-Cell Bolt-On is the version that is fitted on the supporting structure. The Load Stand II is a structural element placed directly between the vessel and the foundation, which is not an ordinary load cell. For classic installations there is the LD3 compression cell and the LD360S, a sanitary washdown cell compatible with CIP cleaning, as well as the TC1 and TC2 tension cells for suspended vessels, with a capacity of up to 50,000 kg. The Load Disc II, LD3xi and LD3xiC are compression systems with a stated accuracy of up to 0.03%. The SVS2000 controller is a high-performance weight indicator, and AccuBin is a level monitoring system for silos.

The brand appears on silos, reactors and tanks in the process industry, where weighing is done either with sensors fixed to the structure or with classic cells. When replacing, the sensor type, the gauge length and the mounting method must be respected.

What do we supply from the Kistler-Morse range?

ProductDescription
Microcell Bolt-OnStrain-gauge sensor fixed to the vessel that produces a signal proportional to the change in weight; it is the product that gave the company its name and can be fitted without lifting the vessel.
Load Stand II and L-CellThe Load Stand II is a structural element between the vessel and the foundation, which is not a classic cell; the L-Cell Bolt-On is attached to the supporting structure and measures the strain in it.
LD3, LD360S, TC1 / TC2, Load Disc cellsThe LD3 cell under the support, the sanitary LD360S with CIP washdown, the TC1 and TC2 tension cells for suspended vessels and the Load Disc II, LD3xi and LD3xiC for precision compression systems.
SVS2000 and AccuBinThe SVS2000 is a high-performance weight indicator for one or more vessels, and AccuBin is an inventory management system for silos.

Why Kistler-Morse?

  • Microcell Bolt-On sensors fitted to an existing vessel — weighing the contents without lifting or dismantling the vessel
  • Classic compression and tension cells (LD3, LD360S, TC1, TC2) — an alternative when the vessel can be supported on cells
  • LD360S for washdown environments, CIP-compatible — for sanitary tanks in food and pharmaceuticals
  • TC1 and TC2 with a capacity of up to 50,000 kg — for suspended vessels, in alloy steel with nickel plating
  • SVS2000 controller and AccuBin inventory system — weighing and silo inventory management in the same ecosystem

Which Kistler-Morse codes and series are requested most often?

CodeDescription
MicrocellStrain-gauge sensor with bolt-on mounting
L-CellSensor mounted on the supporting structure
Load Stand IIStructural element directly between the vessel and the foundation
LD3General-purpose compression cell
LD360SSanitary cell, CIP-compatible
TC1Alloy steel tension cell, nickel-plated
TC2Tension cell, up to 50,000 kg
Load Disc II (LDII)Low-profile cell with semiconductor transducer
LD3xiCompression system with accuracy of up to 0.03%
LD3xiCCompression system for heavy loads, with cage
SVS2000High-performance weight indicator
AccuBinSilo inventory monitoring system

Where is Kistler-Morse equipment used?

  • Silos and bins — weighing the contents with Microcell sensors
  • Sanitary tanks — LD360S with CIP washdown
  • Process industry — suspended vessels with TC1 and TC2 cells
  • Chemicals and bulk materials — Load Disc and Load Stand II systems
  • Inventory management — AccuBin for silo levels

How do we supply Kistler-Morse in Romania?

We can quote Microcell and L-Cell sensors, LD3 and TC cells, SVS2000 indicators and associated components, if you send us the model or the vessel data. Supply is to order, usually in 1–4 weeks; systems for several vessels or with configured instrumentation may have a longer lead time, depending on the specification. For an accurate quotation you need to specify the vessel type (leg, wall, suspended), the material and wall thickness, the maximum mass of the contents, the number of sensors and whether washdown or a hazardous area is required. For a replacement, also send the label of the existing sensor.

Fitting the sensors on the structure is left to a qualified installer.

Frequently asked questions about Kistler-Morse

What does Kistler-Morse make?

The brand, founded in 1974, makes weighing sensors for vessels (Microcell, L-Cell, Load Stand II), load cells, controllers such as the SVS2000 and the AccuBin inventory management system.

How do I choose between a Microcell and a compression cell?

The Microcell is fixed to an existing vessel and does not require it to be lifted, while the LD3 or Load Disc cells are fitted under the legs, as supporting elements. The choice depends on access to the structure; we need the vessel type, the mass and the wall thickness.

Can Kistler-Morse products be supplied in Romania, and how quickly?

Kistler-Morse sensors and controllers are supplied to order, usually in 1–4 weeks. Systems with several vessels or special configurations sometimes need longer; the quotation fixes the lead time.

Can I replace a Microcell sensor with another model?

Only after checking the type, the gauge length and the signal. Equivalences are confirmed after checking: send the sensor label, the vessel type and the connection diagram, and we check the compatible version.

What should I send for a quotation for a TC1 or TC2 cell?

The maximum weight of the vessel with its contents, the number of suspension points, the working environment and whether an anticorrosion coating is needed. The capacity reaches 50,000 kg, so state the total mass.

How do I request a Kistler-Morse quotation?

Send the Kistler-Morse code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 23 November 2026 · Sources: Venture Measurement Co. LLC (manufacturer documentation)