MAURER supplier in Romania
For MAURER we quote MHD hydraulic dampers, SHARK® hysteretic dampers, sliding and elastomeric isolators and tuned mass dampers; we start from the forces, displacements and standard in the project.
Founded in 1876 · Headquarters: Munich, Germany
Who is MAURER and what does it make?
MAURER is a German manufacturer from Munich, founded in 1876 as a steel construction company and still privately owned. The company makes products for transmitting and controlling forces and movements in bridges, buildings and structures with dynamic behaviour: expansion joints, structural bearings, tuned mass dampers, seismic protection devices, vibration isolation systems and monitoring systems. The headquarters and main plant are in Munich, with a secondary site in Lünen and a factory in Bernsdorf, and there is also in-house production in China, Turkey and India.
In the area of seismic protection, the company offers isolators (SIP sliding pendulums, SI sliding isolators, MLRB elastomeric bearings) and dampers. The MHD hydraulic dampers dissipate energy by passing fluid through orifices or valves, with a velocity-dependent response force, for loads below 10 MN and temperatures from −50 to +80 °C. The SHARK® hysteretic dampers work depending on displacement, below 2.6 MN. Both families conform to the applicable standards, as stated in the manufacturer's documentation.
Interest arises for bridges and viaducts, for tall buildings or buildings sensitive to vibration, for footbridges and for industrial structures where wind or pedestrian vibrations must be damped. Requests usually come through the designer and start from a specification with design displacements and forces. The project documentation must also state the standard applicable to the devices.
What do we supply from the MAURER range?
| Product | Description |
|---|---|
| MHD hydraulic dampers | They dissipate seismic energy by forcing fluid through orifices or valves. Below 10 MN, temperature from −50 to +80 °C, service life of over 50 years, no regular maintenance in normal operation. Versions with a hinge at both ends or with a flange. |
| SHARK® hysteretic dampers | Displacement-dependent devices, specified according to EN 15129, for forces below 2.6 MN and temperatures between −40 and +50 °C. They are also used in buildings where the displacement capacity required is moderate. |
| Seismic isolators: SIP, SI and MLRB | Special bearings that decouple the structure from the foundation: SIP-A, SIP-D and SIP sliding pendulums, SI sliding isolators and MLRB, MLDRB and MHDRB elastomeric bearings, with horizontal displacement capacity and return to the initial position. |
| MTMD-V and MTMD-H tuned mass dampers | Mass-spring system tuned to the natural frequency of the structure, vertical or horizontal, for towers, tall buildings, chimneys and grandstands. They are made to order, in collaboration with the structural designer, on the basis of the mass, frequency and damping required. |
Why MAURER?
- MHD hydraulic dampers — response force adjustable through the damping exponent α between 0.04 and 2.0, for the requirements of each structure
- SHARK® hysteretic dampers — displacement-dependent operation, without fluid, below 2.6 MN
- Conformity with the applicable standards, as stated in the manufacturer's documentation — for seismic protection devices
- Tuned mass dampers designed for each structure — passive or adaptive version, with real-time tuning of frequency and damping
- Vibration isolation with steel springs — vertical movements of ±50 mm and horizontal below ±30 mm, with a service life of over 50 years
Which MAURER codes and series are requested most often?
| Code | Description |
|---|---|
| MHD | Velocity-dependent hydraulic damper, below 10 MN |
| SHARK® | Displacement-dependent hysteretic damper, below 2.6 MN |
| SIP-A | Adaptive sliding pendulum |
| SIP-D | Sliding pendulum |
| SIP | Standard sliding pendulum |
| SI | Sliding isolator |
| MLRB | Elastomeric bearing for seismic isolation |
| MLDRB | Elastomeric bearing for seismic isolation, MLDRB version |
| MHDRB | Elastomeric bearing for seismic isolation, MHDRB version |
| MTMD-V | Vertical tuned mass damper, passive |
| MTMD-H | Horizontal tuned mass damper, passive |
| Pot bearings EN 1337 | Pot bearings, TGa, TGe, TGeq, Tf |
Where is MAURER equipment used?
- Bridges and viaducts — expansion joints and structural bearings
- Tall buildings and buildings at seismic risk — isolators and dampers
- Towers, chimneys and footbridges — tuned mass dampers
- Buildings with traffic or machinery vibrations — steel springs for isolation
How do we supply MAURER in Romania?
We can take requests for MAURER products in the field of dampers, isolators and vibration isolation, where the project already has the forces and displacements calculated. The devices are supplied to order, and depending on the specification, the lead time may be longer. For a correct quotation, send the specification or the data sheet of the device: the nominal force, the design displacement, the type of structure, the temperatures, the standard required (EN 15129 or another) and the quantity. For an existing damper, give the code from the nameplate.
The seismic protection device is sized by the designer; we quote on the basis of the parameters the designer sets.
Frequently asked questions about MAURER
What does MAURER make?
MAURER makes expansion joints for bridges, structural bearings, seismic protection devices (isolators and dampers), tuned mass dampers, vibration isolation systems in steel and elastomers, and monitoring systems. The company is based in Munich and was founded in 1876.
How do I choose between an MHD damper and a SHARK one?
The MHD is velocity-dependent, with high displacement capacity and energy absorption, for forces below 10 MN. The SHARK® is displacement-dependent, below 2.6 MN, with medium to large dimensions. The choice comes from the designer's specification; send us the design force and displacement.
Do you bring MAURER products to Romania, and how quickly?
Yes, but only per project: the items are configured for each structure, so they are supplied to order. Depending on the specification, the lead time may be longer for MAURER items. The lead time is confirmed in the quotation.
Can I replace an existing damper or bearing?
It can be checked, if we have the code from the nameplate, the installation drawing and the design forces. Equivalence is confirmed on the basis of these data, because the devices are specified according to EN 15129 or another standard imposed by the project.
What data should I send for a quotation?
The data sheet or the extract from the project: the type of device, the nominal force, the maximum displacement, the extreme temperatures, the standard (EN 15129, EN 1337 or another), the mounting position and the number of units. An assembly drawing speeds up the check. Also mention whether CE marking is needed.
How do I request a MAURER quotation?
Send the MAURER code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: MAURER SE (manufacturer documentation)

