Maximator supplier in Romania
High-pressure hydraulic/pneumatic pumps and pressure amplifiers
Headquarters: Nordhausen, Germany
Who is Maximator and what does it make?
Maximator is a German manufacturer specialised in high-pressure technology, hydraulics and pneumatics, headquartered in Nordhausen. The core range comprises air- or hydraulically driven high-pressure pumps organised in the M, S and G series, each with D (double-acting), 2 or 3 (different amplification ratios) and SS (stainless steel) variants, complemented by air amplifiers of the MPLV, SPLV and GPLV series. On top of these, the company has developed a line dedicated to hydrogen — HULC compression systems, X-TOWER filling towers and GFS gas filling systems.
What sets Maximator apart in the category of pressure pumps and amplifiers is the pressure range reached — up to 152,000 psi for individual components (valves, fittings, tubing) and up to 4,000 bar for complete hydraulic systems, with pressures of up to 900 bar for the X-TOWER towers dedicated to hydrogen. The pressure range is relevant for extreme-pressure tests or gas filling at high pressures.
For the Romanian market, the Maximator range makes sense for hydraulic/pneumatic test benches, gas filling stations and hydrogen infrastructure projects, where working pressures exceed what standard hydraulic process equipment can offer.
What do we supply from the Maximator range?
| Product | Description |
|---|---|
| High-pressure pumps, M/S/G series | Three families of air- or hydraulically driven pumps for generating high pressure in test or process circuits, with D variants for double action, 2/3 for different amplification ratios and SS for stainless steel execution. The choice of series depends on the maximum pressure required and on the fluid handled (oil, water, gas). |
| Air amplifiers MPLV/SPLV/GPLV | Pneumatic amplifiers that convert a low supply pressure into a higher output pressure, typically used on test benches or lines where the network pressure is not enough for the final application. The three series correspond to the basic M, S, G ranges. |
| Hydrogen compression systems HULC / X-TOWER / GFS | Line dedicated to hydrogen infrastructure: HULC for gas compression, X-TOWER as a modular hydrogen compression system up to 900 bar, GFS for gas filling systems. Typical application: hydrogen refuelling stations or cylinder filling lines. |
| Pressure components (valves, fittings, tubing) | A range of valves, fittings and tubing for pressures of up to 152,000 psi, used to build the high-pressure circuits around Maximator pumps and amplifiers or as complementary parts for existing installations. |
Why Maximator?
- Very wide pressure range — up to 152,000 psi on components and 4,000 bar on complete hydraulic systems
- Line dedicated to hydrogen — HULC compression, the X-TOWER modular compression system up to 900 bar, GFS filling systems
- Three pump families (M, S, G) with D, 2/3 and SS variants for different materials and amplification ratios
- Own air amplifiers (MPLV/SPLV/GPLV) for pneumatic test lines
- ISO 9001, ISO 14001 and ISO 50001 certified for quality, environment and energy management
Which Maximator codes and series are requested most often?
| Code | Description |
|---|---|
| M series | High-pressure pump, basic M family |
| M...-2 series | M variant with amplification ratio 2 |
| M...-3 series | M variant with amplification ratio 3 |
| M...D series | M variant with double action |
| MO series | Pump variant from the M family |
| MO...D series | MO variant with double action |
| MSF series | high-pressure pump from the M family |
| S series | High-pressure pump, S family |
| S...D series | S variant with double action |
| S...-SS series | S variant in stainless steel |
| G series | High-pressure pump, G family |
| G...-2 series | G variant with amplification ratio 2 |
| G...D series | G variant with double action |
| GSF series | high-pressure pump from the G family |
| GX series | high-pressure pump from the G family |
| GPD series | high-pressure pump from the G family |
| GPD...-2 series | GPD variant with amplification ratio 2 |
| MLGP series | Pump for liquefied gases, M family |
| SLGP series | Pump for liquefied gases, S family |
| GLGP series | Pump for liquefied gases, G family |
| MPLV series | Air amplifier, M family |
| SPLV series | Air amplifier, S family |
| GPLV series | Air amplifier, G family |
| HULC | Hydrogen compression system |
| X-TOWER | Modular hydrogen compression system, up to 900 bar |
| GFS | Hydrogen gas filling system |
Where is Maximator equipment used?
- Alternative energy and hydrogen — compression and gas filling
- Automotive — high-pressure test benches
- Chemicals — high-pressure process circuits
- Semiconductors — precision test equipment
- Oil and gas — high-pressure pumps and components
- Aerospace — extreme-pressure tests
How do we supply Maximator in Romania?
We supply Maximator pumps and pressure amplifiers for test benches and gas filling lines where pressures exceed what standard hydraulic equipment can offer. The information on ranges and parameters comes from the manufacturer's technical documentation; we do not keep these components on our own shelves, and they are supplied to order, usually 1–4 weeks from placing the order, depending on the manufacturer's confirmation for the requested series and material. For a quotation we need the required working pressure, the fluid handled and, where applicable, the desired amplification ratio. We do not promise warehouse availability for any series in the range.
We supply the components of the published range; the integration and software configuration of complete hydrogen filling systems are outside our offer.
Frequently asked questions about Maximator
What products does Maximator make?
Maximator manufactures hydraulic and pneumatic pressure pumps and amplifiers (M, S, G series), high-pressure components and hydrogen compression/filling systems (HULC, X-TOWER, GFS), used on test benches and high-pressure process installations.
How do I choose a Maximator pump by series?
The choice between the M, S and G series depends on the maximum pressure required and on the amplification ratio; D variants are double-acting, and SS variants are stainless steel for corrosive media. Final confirmation requires the available inlet pressure and the working fluid.
What is the equivalent of the Maximator X-TOWER series?
X-TOWER is the Maximator modular hydrogen compression system, up to 900 bar; an equivalent has to cover the same pressure and the required gas flow, checked against the requirements of the refuelling station.
How fast do you deliver Maximator equipment in Romania?
Maximator pumps and amplifiers are brought in to order through EU supply channels, usually within 1–4 weeks until the manufacturer confirms the requested series. We do not keep this equipment on our shelves.
What data should I send for a Maximator pump quotation?
The required working pressure, the fluid handled (oil, water, gas), the desired amplification ratio and the type of drive available (pneumatic or hydraulic) at the installation site.
How do I request a Maximator quotation?
Send the Maximator code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 12 November 2026 · Sources: Maximator GmbH (manufacturer documentation)

