Minimax supplier in Romania

Fire protection for turbines: TurbineProtect, Minifog, MXOne

Founded in 1902 · Headquarters: Bad Oldesloe, Germany

Request a quote

Who is Minimax and what does it make?

Minimax is a German fire protection manufacturer based in Bad Oldesloe, active since 1902. Today its range covers fire detection, water systems (sprinkler, deluge), Minifog water mist, foam, inert gas and CO2, compact systems, prevention by oxygen reduction and the Inveron hazard management system. The line described below is the one relevant to power plants and turbines.

TurbineProtect is the solution dedicated to industrial gas turbines used to drive generators or compressors. Inside the acoustic enclosure the temperature can reach 120 °C and the turbine surface 800 °C; leaked oil ignites easily and the large flow of cooling air spreads the fire. The solution combines UniVario industrial detectors, a detection and extinguishing control panel and, as an option, CO2 extinguishing (high or low pressure), Oxeo inert gases (argon or nitrogen) or Minifog ProCon XP water mist, which uses about 95% less water than conventional sprinkling. Inveron gathers the data in a single interface.

It is relevant for combined-cycle power plants, gas compression stations and industrial units with turbines, where the machine enclosure has its own extinguishing system. MXOne, the water-driven extinguishing turbine, adds protection of large areas, with a certified throw of 37 m with mist and 100 m with full jet. Items are identified by the system series and by the type of extinguishing agent.

What do we supply from the Minimax range?

ProductDescription
TurbineProtectIntegrated solution for industrial gas turbines: UniVario detectors, detection and control panel, extinguishing with CO2, Oxeo or Minifog ProCon XP, Inveron visualisation. It can be supplied in pre-assembled containers.
Minifog ProCon XPHigh-pressure water mist system that protects engines, turbines and other machinery, with low water consumption. It covers spaces of up to 2,430 m³ and 13.5 m in height, in multi-zone configurations.
UniVarioIntelligent industrial fire detectors with signal processing that can be configured for the application. Usable indoors and outdoors, in clean rooms and in harsh conditions, including in explosion-hazard areas.
MXOneExtinguishing turbine that projects water mist or a jet, for large areas with a risk of fire outbreak and spread. 360° rotation and automatic or radio-controlled operation.

Why Minimax?

  • TurbineProtect is designed for turbine enclosures — conditions of up to 120 °C in the enclosure and 800 °C on the turbine surface are taken into account
  • Choice of extinguishing agent: CO2, Oxeo inert gas or Minifog ProCon XP mist — a solution adapted to the turbine size and the available space
  • Minifog ProCon XP uses about 95% less water than conventional sprinkling — less risk of thermal deformation of hot parts
  • UniVario detectors work indoors and outdoors, including in explosion-hazard areas — a single family across the whole site
  • MXOne has a certified throw of 37 m (mist) and 100 m (full jet) — protection from a distance for large areas, tested by FM Global

Which Minimax codes and series are requested most often?

CodeDescription
TurbineProtectIntegrated solution for industrial gas turbines
MXOneExtinguishing turbine with water mist or jet
UniVarioIndustrial fire detectors
Minifog ProCon XPHigh-pressure water mist for machinery
Minifog ProConMinifog ProCon water mist system
Minifog ECONAQUAMinifog ECONAQUA water mist system
Minifog Marine XPMinifog version for naval applications
OxeoInert gas extinguishing systems (argon, nitrogen)
InveronHazard management system
Clunid FMZFire detection and extinguishing control panel
HeliosAspirating smoke detectors
CPS 1230Compact system for cabinet protection

Where is Minimax equipment used?

  • Combined-cycle power plants — gas turbines and auxiliary installations
  • Compression and liquefaction stations — turbines for mechanical drives
  • Cogeneration — turbine and machine enclosures
  • Wind energy — protection of nacelles and associated installations
  • Steel industry — installations with a fire risk

How do we supply Minimax in Romania?

From the Minimax range we can check UniVario detectors, components for Minifog and Oxeo systems, valves, nozzles and accessories, starting from the system series and the codes in its documentation. They are supplied to order; the lead time is usually 1–4 weeks, and for complete or containerised extinguishing systems it can be much longer, confirmed in the quotation. For a request, the following are useful: the type of agent (CO2, inert gas, water mist), the turbine manufacturer, the protected volume and the classified area. Design, installation and acceptance are carried out by specialist firms.

Complete extinguishing systems are quoted only on the basis of an approved design, and items with design-dependent approvals are not replaced without documentation.

Frequently asked questions about Minimax

What does Minimax make for power plants?

Minimax, from Bad Oldesloe, offers the TurbineProtect solution for turbines: UniVario detectors, a control panel and extinguishing with CO2, Oxeo inert gases or Minifog ProCon XP water mist, with Inveron visualisation. For large areas there is the MXOne extinguishing turbine.

How do I choose the extinguishing agent for a gas turbine?

The choice depends on the size of the enclosure, the space for cylinders and the risk of re-ignition. CO2 or Oxeo leave no residue; Minifog ProCon XP mist uses about 95% less water. The enclosure dimensions and the turbine data let us orient the request.

Do you supply Minimax components in Romania, and how long does it take?

Yes. UniVario detectors and Minifog or Oxeo components are supplied to order, usually in 1–4 weeks. Complete or containerised TurbineProtect systems have much longer lead times, which we set in the quotation.

Can I replace an old detector with a UniVario?

Compatibility is confirmed from the code and the control panel data. We check the detector type, the connection protocol and the classified area, then identify the model that fits. The answer comes before the quotation, not after the order.

What information do you need for a Minimax quotation?

The system series, the item codes, the type of extinguishing agent, the protected volume and the area classification. If it concerns a turbine, add its manufacturer and model. A simple diagram of the enclosure and the detector positions makes it easier to identify the items.

How do I request a Minimax quotation?

Send the Minimax code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote