Pickering Interfaces supplier in Romania
PXI and LXI switching and simulation modules for automated test systems
Founded in 1988 · Headquarters: Clacton-on-Sea, United Kingdom
Who is Pickering Interfaces and what does it make?
Pickering Interfaces is a British company from Clacton-on-Sea, founded in 1988. It makes signal switching and simulation modules for automated test systems, in PXI, LXI, USB and PCI formats, plus cables and connectors, diagnostic instruments and software. It manufactures in the United Kingdom and in the Czech Republic, at Třinec.
The role of such a module is to connect measuring instruments quickly to several points of the product under test, without manual rewiring. Pickering offers multiplexers, matrices, general-purpose switches, high-voltage and power switching, RF and microwave switching and fault insertion boards. On the simulation side, the modules include programmable resistors, battery simulators, LVDT/RVDT/resolver simulators and current loop simulators.
For high voltage and power installations, the relevant ones are the high-voltage LXI modules, for example a module with 10 SPST reed relay switches, capable of cold switching up to 7 kV and hot switching up to 5 kV, or a 750 V matrix with 50×4 points. Battery simulators for cell stacks are used for testing battery management systems. These products are used in test benches for electrical equipment, in test laboratories and by electronics makers who automate their functional test.
What do we supply from the Pickering Interfaces range?
| Product | Description |
|---|---|
| High-voltage LXI switching | Modules for LXI chassis, for example 10×SPST with reed relays for cold switching up to 7 kV and hot switching up to 5 kV, or a 750 V matrix with 50×4 points, for electrical test benches. |
| PXI/PXIe battery simulators | Modules that emulate battery stacks and power supplies. The 41/43-754 and 41/43-752A models target electric vehicle stacks, and the 41-753 simulates a single cell. |
| LVDT/RVDT/resolver simulators | PXI/PXIe modules with up to 2 channels of 5/6 wires or 8 channels of 4 wires, in nearly 150 configurations, for simulating position sensors in test benches. |
| PXI, PXIe and LXI chassis and controllers | Chassis for switching and simulation modules, controllers and LXI chassis of 2U/6 slots or 4U/15 slots, for automated test benches. |
Why Pickering Interfaces?
- High-voltage LXI switching, up to 7 kV cold — suited to benches for testing insulation and medium voltage equipment
- PXI battery simulators with high isolation barriers — testing battery management systems without real stacks
- Switching, simulation, cables and chassis from the same range — fewer sources of incompatibility in a test bench
- Over 1000 PXI/PXIe modules in the range — there is usually a configuration close to the real need
- LVDT/RVDT/resolver simulators with 150 configurations — they replace the real sensor in position test benches
Which Pickering Interfaces codes and series are requested most often?
| Code | Description |
|---|---|
| 65-233-704 | High-voltage LXI module 10×SPST, cold switching up to 7 kV |
| 65-233-703 | High-voltage LXI module, 65-233 family |
| 65-218-111 | High-voltage LXI matrix 750 V, 50×4 |
| 65-218-101 | High-voltage LXI matrix, 65-218 family |
| 65-231-713 | High-voltage LXI module, 65-231 family |
| 65-231-710 | High-voltage LXI module, 65-231 family |
| 41-670-103 | PXI/PXIe LVDT/RVDT simulator, 2 banks |
| 41-754 / 43-754 | PXI/PXIe battery simulator for electric vehicle stacks |
| 41-752A / 43-752A | PXI/PXIe battery simulator for cell stacks |
| 41-753 | Single battery cell simulator |
Where is Pickering Interfaces equipment used?
- Power and high voltage — signal switching for electrical test benches
- Electric mobility — battery stack simulation for BMS testing
- Rail and aerospace — simulation of LVDT/RVDT position sensors
- Electronics manufacturing — automated functional testing of boards
- Hardware-in-the-loop — fault insertion and resistor simulation
How do we supply Pickering Interfaces in Romania?
From the Pickering range we can quote switching modules, simulators, PXI and LXI chassis, cables and accessories. The modules are supplied to order, usually in 1–4 weeks. Modules with many configuration variants or assembled systems may have a longer lead time, confirmed in the quotation. For a correct request we need the code of the module or the chassis, the voltage and current switched, the contact type (reed, electromechanical), the number of points and the format wanted (PXI, PXIe, LXI). For replacements, a photo of the label of the old module helps us.
Mechanical compatibility of a new module with a very old chassis is checked on the exact code of both components.
Frequently asked questions about Pickering Interfaces
What does Pickering Interfaces make?
Pickering Interfaces makes signal switching and simulation modules in PXI, LXI, USB and PCI formats, plus chassis, cables, connectors and software for automated test systems. They are used for functional testing, hardware-in-the-loop and electrical checks.
How do I choose a Pickering switching module by voltage and current?
The maximum voltage switched, the current, the contact type and whether switching is cold or hot matter. For high voltage, LXI modules with reed relays reach 7 kV cold and 5 kV hot. With these data and the number of points we can narrow down the choice.
Can you supply Pickering modules in Romania, and within what lead time?
Yes. Switching and simulation modules, chassis and cables are supplied to order, usually in 1–4 weeks. Modules with many configuration variants or assembled systems may take longer; the exact lead time appears in the quotation.
Can I replace a Pickering module withdrawn from production with a current one?
The first PXI modules from the 1990s are still in production, but each case is checked on the code. Send the number from the label of the module, the chassis type and the driver version, so that we establish which version would correspond.
What do I send for a quotation on a battery or LVDT simulator?
For a battery we need the number of cells in series, the voltage per cell, the charge and discharge current and the isolation level. For LVDT/RVDT, the number of channels, the number of wires and the excitation voltage. From these the suitable model is chosen.
How do I request a Pickering Interfaces quotation?
Send the Pickering Interfaces code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 23 November 2026 · Sources: Pickering Interfaces Ltd, Wikipedia (manufacturer documentation)