Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Pilz supplier in Romania

For Pilz we offer PNOZ X and PNOZ s safety relays, PNOZmulti 2 safety controllers and PSENopt light curtains; the code on the relay or on the nameplate helps us find the exact variant or its successor.

Founded in 1948 · Headquarters: Ostfildern, Germany

Request a quote

Who is Pilz and what does it make?

Pilz GmbH & Co. KG develops industrial safety technologies and safe automation. Founded in 1948, the company introduced the PNOZ safety relay for emergency stop circuits in 1987; the freely configurable PNOZmulti safety system appeared in 2002. Today Pilz offers a complete safe automation ecosystem: safety relays, safety PLC controllers, safety sensors (light curtains, door switches, safety laser scanners), two-hand control systems, distributed safety I/O modules. When a machine is designed according to EN ISO 13849-1 or IEC 62061 and has to reach Performance Level PLe or SIL3, Pilz components can also be used, with the certifications indicated by the manufacturer for each model.

PNOZ technology covers all safety functions: emergency stop monitoring, safety gate monitoring with guard locking, two-hand control, speed/standstill monitoring, light curtain evaluation. PSENcode coded systems for access protection prevent simple defeat. PSENopt light curtains, available in Type 2, Type 3 and Type 4 variants, for finger, hand or body protection. SafetyEYE is a safe camera system for 3D monitoring of a space. PNOZmulti 2 combines programmable safety logic with integrated I/O in a single unit configurable by software. The PSS4000 PLC offers safety logic, with variants with functional safety according to the manufacturer's documentation, integrated with standard automation on a single platform.

Pilz has 42 subsidiaries and branches worldwide. Certifications and safety levels (PL, SIL) differ by model and are confirmed from the data sheet. Pilz offers configuration software for sensors (PSENopt Configurator, PSENscan Configurator). The technical documentation of Pilz components is that of the manufacturer.

What do we supply from the Pilz range?

ProductDescription
PNOZ X/S safety relaysElectromechanical safety relays for monitoring basic safety functions. PNOZ X - range for emergency stop (1-2 channels), safety gates (with/without guard locking), two-hand control, light curtain monitoring. Principle: redundant dual-channel architecture with self-monitoring - if one channel fails, the relay does not allow a dangerous restart. Forcibly-guided output contacts according to EN 50205 - ensures that NO and NC contacts cannot be closed simultaneously. The safety level (category, PL, SIL) differs by model and is confirmed from the data sheet. PNOZ s (PNOZsigma) - compact versions, from 12.5 mm width, for dense panels. DIN rail mounting EN 60715. Screw terminal or spring-cage connection. LED status indicator per channel for diagnostics. Manual, automatic or monitored manual reset depending on the application. Applications: protection of presses, machine tools, robots, packaging lines. Approvals according to the manufacturer's documentation; the temperature range is confirmed from the data sheet of the model. Detailed manual with wiring diagrams for each standard application. Certifications and safety levels are confirmed from the data sheet of the model.
PNOZmulti 2 safety controllersModular safety control system configurable by software. Base unit with safety processor + I/O expansion modules. Safety functions: multi-channel emergency stop, safety gates with locking, muting, blanking, two-hand control, speed monitoring, standstill detection, safe motion (SLS, SSR, STO). Safety levels (PL, SIL) are confirmed from the data sheet of the configuration. Programming through PNOZmulti Configurator software. I/O expansion: modules with 8/16 safety inputs, 4/8 safety outputs, standard non-safety inputs/outputs, communication modules (PROFINET, EtherNet/IP, Modbus TCP). Base unit with display for text diagnostics. Applications: complex machines with multiple safety zones, production lines with interlocks, systems with guard locking and escape release, replacement for large panels with dozens of discrete relays. Dramatic savings in space and wiring compared with individual relay solutions. Simulation mode for testing logic without connected equipment. Version management - audit trail for configuration changes. The temperature range and certifications are confirmed from the data sheet of the model.
PSENopt Advanced light curtainsSafety light curtains for protecting hazardous zones without physical barriers. Technology: infrared LED emitter array + multi-beam receiver. Resolution determines the minimum size of the detectable object (protection for fingers, hands or body); resolutions, protective field heights, operating distance and response time are confirmed from the data sheet of the model. The response time is needed to calculate the minimum safety distance according to EN ISO 13855. Advanced functions: muting (lets a pallet pass without stopping the machine), blanking (ignores fixed objects in the field), floating blanking (tracks a permitted moving object). Functions such as muting, blanking or cascading are configured through the PSENopt Configurator software. Applications: protection of presses, robots, packaging machines, access to hazardous zones. The degree of protection and the connection technology are confirmed from the data sheet of the model. Diagnostic LEDs + digital signals for fault finding. Available in Type 2, Type 3 and Type 4 variants, up to PL e; the exact level is confirmed from the data sheet. Conformity EN IEC 61496, ISO 13849-1.
PSENscan safety laser scanner2D safety laser scanner for zone monitoring and reducing robot speed. Principle: protective field of up to 5.5 m, with detection resolutions of 30, 40, 50, 70 and 150 mm. Scanning field with 275° coverage. Multiple zone configuration: red zone (immediate stop), orange zone (warning/reduce speed), green zone (safe). Functions: static protective field, warning field, dynamic field switching (changes zones depending on machine position), field pair switching. Applications: collaborative robotics (cobots), AGV/AMR autonomous vehicles, restricted access zones, perimeter protection. Variants with functional safety. Side or overhead mounting. Ethernet connection for configuration + OSSD outputs for safety stop. PSENscan Configurator software visualises zones and allows quick teach-in. IP65 housing, dust/water resistant. Temperature -10°C to +50°C. Remote diagnostics over Ethernet - zone status, contamination level of the window. Periodic functional test according to EN 61496.

Why Pilz?

  • Over 75 years of experience in safety automation
  • PNOZ safety relays; the safety level (PL/SIL) differs by model and is confirmed from the data sheet
  • PSENopt light curtains and PSENscan safety scanners for robotics
  • PNOZmulti safety controllers and PSS4000 PLC with programmable logic
  • PSENopt Configurator and PSENscan Configurator configuration software
  • Technical support and training in safety standards

Which Pilz codes and series are requested most often?

CodeDescription
PNOZ X1Compact safety relay for emergency stop button
PNOZ X2Safety relay for monitoring a safety gate
PNOZ X3Safety relay with time-delay function
PNOZ X4Safety relay for emergency stop and safety gate
PMUT X1PSafety relay for sensor muting function
PSWZ X1PSafety relay for standstill and voltage monitoring
PNOZ s1Modular safety relay for emergency stop circuit
PNOZ s3Modular safety relay for safety gate
PNOZ s4Modular safety relay with additional contacts
PNOZ s4.1Variant of the PNOZ s4 modular relay
PNOZ s5Modular safety relay with time-delay function
PNOZ s6Modular relay for monitoring two-hand control
PNOZ s7Contact expansion module for the PNOZsigma series
PNOZ s9Modular safety relay with off-delay
PNOZ s20Higher-capacity contact expansion module

Where is Pilz equipment used?

  • automotive
  • machine-building
  • packaging
  • robotics
  • material-handling
  • woodworking
  • food-beverage
  • pharma
  • metalworking
  • logistics

How do we supply Pilz in Romania?

For Pilz safety equipment, we start from the manufacturer's technical documentation, and the official Performance Level calculation for your machine is outside our offer. Components can ship in 24–72 h when the item is in stock, locally or at the supplier; PNOZ relays, light curtains or less common scanners arrive to order, typically in 1–4 weeks. For a correct quotation, send us the required safety category, the type of application and the component code if you already have it. We check real availability before confirming a lead time, especially for complex PNOZmulti or PSENscan systems.

The official Performance Level calculation and safety validation are outside our offer, and the availability of PNOZ components is confirmed in the quotation.

Frequently asked questions about Pilz

What is the difference between the Pilz PNOZ X and PNOZsigma series?

PNOZ X is the classic series, with a housing of 22.5 to 90 mm and a fixed number of contacts on each model. PNOZsigma is the more compact modular generation, where functions are combined by adding expansion modules, which reduces the space taken up in the electrical cabinet.

Which Pilz safety relay should I choose for monitoring an emergency stop button?

PNOZ X1 or PNOZ s1 are the typical choices for a simple emergency stop circuit, both offering monitoring with one or two channels. The choice between the X series and the s series depends on the space available in the cabinet and the need for later expansion with additional modules.

What contacts, safety level and start modes does the Pilz PNOZ s4 relay have?

PNOZ s4 has 3 instantaneous normally open safety contacts, 1 normally closed auxiliary contact and a semiconductor output. It reaches PL e (EN ISO 13849-1), category 4 and SIL 3. Start mode is set by rotary switch: automatic or manual, monitored on rising or falling edge, or automatic with start-up test. We confirm the exact code with the quotation.

What information should I send for a quotation on Pilz PNOZ relays?

It is useful to mention the required safety function (emergency stop, safety gate or two-hand control), the number of channels and whether a time delay is needed. The full code of the existing relay, if available, helps identify the correct equivalent quickly.

How many safety functions does a Pilz PNOZ X relay cover?

PNOZ X series models usually cover a single safety function per relay, with two to eight contacts, depending on the variant. For several functions combined in the same device, the modular PNOZsigma series allows additional modules to be added to the same base relay.

How do I request a Pilz quotation?

Send the Pilz code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 23 November 2026 · Sources: Pilz, Pilz GmbH & Co. KG (manufacturer documentation)