PTCXPUMP supplier in Romania
Plastic and stainless steel magnetic drive pumps for chemicals
Headquarters: Kaohsiung, Taiwan
Who is PTCXPUMP and what does it make?
PTCXPUMP is a Taiwanese manufacturer of magnetic drive pumps, with no seal, based in the Renwu district of Kaohsiung. The company has over 40 years of experience in chemical fluid transfer, completed its research and began series production in 2014. The pumps are designed for acids and bases, with materials such as SUS316L stainless steel and GFRPP and CFRETFE plastics, and the sealless construction eliminates leaks and emissions of volatile organic compounds.
The range is divided into two lines. The plastic series, from PTC-100 to PTC-251, reaches a head of 21.4 m and 160 l/min with motors of 0.25–0.75 kW, and the PTC-400 – PTC-675 series reaches 46 m and 1006 l/min with motors of 0.37–7.5 kW. The stainless steel metal series is divided into PM (small size, for OEM equipment and laboratories, from -80 to 280 °C), PS (medium capacity), PL (high flow, motor up to 18.5 kW), PW (high head and low flow) and FPM, for liquid cooling in data centres, with temperatures down to -100 °C.
Magnetic drive pumps are used for dosing hydrochloric, sulphuric or hydrofluoric acid, solvents and flammable products. It is worth adding a dry-run protector, because the magnetic pump is vulnerable to running without liquid.
What do we supply from the PTCXPUMP range?
| Product | Description |
|---|---|
| PTC plastic magnetic pumps | The PTC-100 – PTC-251 series (up to 21.4 m and 160 l/min, 0.25–0.75 kW) and PTC-400 – PTC-675 (up to 46 m and 1006 l/min, 0.37–7.5 kW), in GFRPP or CFRETFE, for acids, bases and aggressive chemicals. |
| PM, PS, PL, PW metal magnetic pumps | Stainless steel pumps: the small PM, from -80 to 280 °C; the PS of medium capacity; the PL of high flow with a motor of up to 18.5 kW; the PW with high head and low flow, without heating at low flow. |
| FPM series for liquid cooling | Magnetic pump designed for coolant distribution units in data centres and liquid-cooled servers, with a volume reduced by a third and working temperatures down to -100 °C. |
| Dry-run protector | Device that monitors the motor current or power and stops the pump immediately when the values leave the set range, to avoid overload and damage to components. |
Why PTCXPUMP?
- No mechanical seal — magnetic drive, so no leaks at the shaft and no VOC emissions when transferring acids and solvents
- GFRPP, CFRETFE and SUS316L materials — chosen by fluid: plastic for acids and bases, stainless steel for solvents and extreme temperatures
- Metal series by flow range — PM for OEM and laboratory, PS for general use, PL for high flow and PW for high head with low flow
- Wide temperature range on the metal pumps — from -80 up to 280 °C on the PM series
- Dry-run protector available — it monitors the current and stops the pump before the bearings overheat
Which PTCXPUMP codes and series are requested most often?
| Code | Description |
|---|---|
| PTC-100 | Plastic magnetic pump, small series |
| PTC-251 | Plastic magnetic pump, upper limit of the small series |
| PTC-400 | Plastic magnetic pump, large series |
| PTC-675 | Plastic magnetic pump, upper limit of the large series |
| PM | Stainless steel magnetic pump, small size, -80 to 280 °C |
| PS | Stainless steel magnetic pump, medium capacity |
| PL | Stainless steel magnetic pump, high flow, motor up to 18.5 kW |
| PW | Stainless steel magnetic pump, high head, low flow |
| FPM | Magnetic pump for liquid cooling in data centres |
| Dry-run protector | Device for stopping on abnormal current or power |
Where is PTCXPUMP equipment used?
- Chemicals and petrochemicals — transfer of acids, bases and solvents
- Semiconductors and electronics — high-purity chemicals
- PCB — etching and cleaning solutions
- Hydrogen and energy — electrolysers and stations
- Data centres — liquid cooling of servers
How do we supply PTCXPUMP in Romania?
We can quote PTCXPUMP magnetic drive pumps, in plastic or stainless steel, to order. The lead time to order is usually 1–4 weeks, and for configurations with special materials it can be longer; it can ship in 24–72 h when the item is in stock, locally or at the supplier. For a correct quotation send us the fluid with its concentration and temperature, the density, the flow and the pumping head, the mains frequency and the connection type. For replacement parts, add the pump model, for example PTC-400 or PS.
The compatibility of the materials with a specific fluid is established on the manufacturer's chemical data sheet for the model in question.
Frequently asked questions about PTCXPUMP
What products does PTCXPUMP make?
PTCXPUMP, from Kaohsiung (Taiwan), makes magnetic drive pumps, with no seal, in GFRPP, CFRETFE and SUS316L stainless steel, for acids, bases and solvents, plus PM, PS, PL, PW metal pumps, the FPM series for liquid cooling and dry-run protectors.
How do I choose between a plastic and a stainless steel magnetic pump?
Plastic (GFRPP or CFRETFE) is suited to acids and bases, at moderate temperatures. Stainless steel is used for solvents, flammable products and temperatures between -80 and 280 °C. Send us the fluid, the concentration and the temperature to establish the material and the series.
Do you supply PTCXPUMP pumps in Romania, and within what time?
Yes, to order. The lead time is 24–72 h when the item is in stock, locally or at the supplier; otherwise, to order, usually 1–4 weeks. Depending on the specification, the lead time can be longer for special configurations, confirmed in the quotation.
Can I protect the magnetic pump against dry running?
Yes, a protector that monitors the motor current or power and stops the pump if the values leave the set range is recommended. For mounting we need the pump model, the voltage and the motor power, so that we can request the compatible protector.
What data do you need for a quotation on a PTCXPUMP pump?
The fluid handled with its concentration and temperature, the density and viscosity, the flow and head needed, the voltage and frequency, the connection type and, if you already have a pump, its model from the nameplate. With these data we check the configuration.
How do I request a PTCXPUMP quotation?
Send the PTCXPUMP code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 23 November 2026 · Sources: PTCXPUMP (manufacturer documentation)