Sartorius supplier in Romania
For Sartorius we quote Sartopore Evo sterilising filters, Sartopure and Sartoguard prefilters, Sartoclear depth filters, Virosart virus filters and stainless steel housings; for a quotation we need the fluid, flow rate, filtration grade and capsule format.
Founded in 1870 · Headquarters: Göttingen, Germany
Who is Sartorius and what does it make?
Sartorius is a German company headquartered in Göttingen and active since 1870. The product line in our offer is process filtration: filters and systems for liquids and gases in biopharmaceutical plants, but also in the chemical and food industries. Filtration appears in almost every stage of a biotechnology workflow: harvest clarification, reduction of the microbial load, final sterilising filtration, buffer exchange and product concentration.
The range is divided by function. Sartopore Evo sterilising filters have a modified polyethersulfone (PES) membrane and are supplied from 4.5 cm², for trials, up to 21.6 m² in the pre-assembled, single-use Maxicaps MR unit. Prefiltration uses Sartopure PP3 and GF Plus, Sartoguard GF and PES and Sartoclean GF, which protect the final filter. Sartoclear depth filters combine cellulose, diatomite and a binder resin for clarifying the harvest after the bioreactor. The Virosart family (HF, HC, CPV, Max) retains viruses downstream, and tangential flow filtration (TFF) uses Sartocon cassettes and Sartoflow holders. For gases and venting there are Sartofluor, Sartopore Air, Midisart 2000 and Sartopure GA, with PTFE, PES, ePTFE or glass fibre membranes. Stainless steel housings, with Maxicaps and Midicaps capsules, cover large volumes, and single-use assemblies come pre-sterilised, with aseptic tubing and connectors. The Sartocheck 5 tester checks filter integrity.
This range is found in biopharmaceutical and pharmaceutical plants and in process installations with sterility requirements, where the filter is chosen by fluid and by process stage.
What do we supply from the Sartorius range?
| Product | Description |
|---|---|
| Sartopore Evo — sterilising filters | Sterilising filters with a modified PES membrane, which reduce the adsorption of proteins and excipients. They are supplied as cartridges for stainless steel installations or as capsules; Maxicaps MR is a pre-assembled, single-use unit, up to 21.6 m². |
| Sartopure, Sartoguard, Sartoclean and Sartoclear — prefiltration and clarification | Particle prefilters (Sartopure PP3), adsorptive depth filters (GF Plus), membrane prefilters (Sartoguard GF and PES) and adsorptive filters for colloids and microbial load (Sartoclean GF). Sartoclear clarifies the harvest from the bioreactor. |
| Virosart and Sartocon — virus filters and TFF | Virus filters with an asymmetric membrane, in capsules and cartridges, from small-scale studies to production. Sartocon and Sartoflow are cassettes and holders for tangential flow filtration, used for concentration and buffer exchange. |
| Gas filters, housings and single-use assemblies | Gas and vent filters with PTFE, PES, ePTFE or glass fibre media, stainless steel housings for Maxicaps and Midicaps, with heated versions, and pre-sterilised assemblies with aseptic tubing and connectors, including for the integrity test before use. |
Why Sartorius?
- Sartopore Evo sterilising filters with a modified PES membrane — formats from 4.5 cm² up to 21.6 m² in Maxicaps MR
- Prefiltration on several media — Sartopure PP3, GF Plus, Sartoguard GF and PES, Sartoclean GF — to protect the final filter
- Sartoclear depth filters in cellulose, diatomite and resin — harvest clarification, in one stage or in two
- Virosart HF, HC, CPV and Max virus filters and Sartocon TFF cassettes, in laboratory and process formats
- Stainless steel housings and pre-sterilised single-use assemblies — the same family for large volumes and for flexible processes
Which Sartorius codes and series are requested most often?
| Code | Description |
|---|---|
| Sartopore Evo | Sterilising filter with modified PES membrane |
| Maxicaps MR | Pre-assembled single-use filtration unit, up to 21.6 m² |
| Sartopure PP3 | Prefilter for particle reduction |
| Sartopure GF Plus | Adsorptive depth filter |
| Sartoguard PES | Prefilter with PES membrane |
| Sartoclean GF | Adsorptive filter for colloids and microbial load |
| Sartoclear | Depth filter for harvest clarification |
| Virosart HF | Virus filter |
| Virosart CPV | Virus filter |
| Virosart Max | Virus filter |
| Sartocon | Cassette for tangential flow filtration |
| Sartofluor | Gas and vent filter |
| Midisart 2000 | Gas and vent filter |
| Sartocheck 5 Plus | Filter integrity tester |
Where is Sartorius equipment used?
- Biopharmaceuticals — harvest clarification, sterilising filtration and virus filtration
- Pharmaceutical industry — sterilising filters for process liquids and gases
- Chemicals — stainless steel housings for large volumes of liquids
- Food and beverage industry — housings and capsules for volume filtration
- Processes with sterility requirements — venting and gas filtration with sterilising filters
How do we supply Sartorius in Romania?
We can quote Sartorius process filters, capsules and cartridges, stainless steel housings and single-use assemblies according to your process data. Filters, capsules and housings are supplied to order, usually in 1–4 weeks; for configured assemblies or housings designed to order, depending on the specification, the lead time can be longer. For a quotation we need the fluid filtered, the flow rate and batch volume, the filtration grade, the temperature, the format required (capsule, cartridge or housing), the connection type and, for replacements, the code on the filter in use. We confirm the exact lead time in the quotation.
Our offer covers process filtration; we confirm a specific filter once we know the fluid, the volume and the validation requirements of the process.
Frequently asked questions about Sartorius
What process filters does Sartorius make?
Sartorius, a German company, has in its range sterilising filters, prefilters, depth filters, virus filters, cassettes for tangential flow filtration, gas and vent filters, stainless steel housings and single-use assemblies, plus integrity testers. They are used in biopharmaceuticals, in the chemical industry and in the food industry.
How do I choose between a sterilising filter and a prefilter?
The prefilter retains particles and reduces the microbial load, to protect the final sterilising filter, the stage that retains the microorganisms in the liquid. The order and the filtration grade depend on the fluid and the batch volume. Send us the fluid and the flow rate, and we request confirmation of the filtration line.
Do you supply Sartorius filters in Romania and how fast?
Sartorius filters are supplied to order, usually in 1–4 weeks; configured single-use assemblies may take longer, depending on the specification. A capsule or cartridge can ship in 24–72 h when the item is in stock, locally or at the supplier.
Can I replace a Sartorius filter used in a validated process?
Only with the same reference, because a validated process does not allow substitutions without re-evaluation. Send us the code on the filter, the format (capsule or cartridge), the connection and the filtration grade. We check the exact reference and its availability.
What data do I need to send for a quotation on a stainless steel housing?
State the fluid and temperature, the working pressure, the flow rate, the type of capsule or cartridge to be fitted (Maxicaps, Midicaps), the materials required and whether you want a heating jacket. Also state the fluid class under the Pressure Equipment Directive (PED), as it affects the approval requirements.
How do I request a Sartorius quotation?
Send the Sartorius code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Sartorius AG (manufacturer documentation)