SEW Eurodrive DRS (IE1)
SEW-EURODRIVE DRS three-phase asynchronous motors, efficiency class IE1, permitted only as replacements under Regulation (EU) 2019/1781; the current series compared in the official document is DRN (IE3).
DRS is the SEW-EURODRIVE series of three-phase motors in efficiency class IE1, used as a standalone motor or as the motor of gear motors. In the official comparison document for Regulation (EU) 2019/1781, the DRS types appear in tables by power step, from 0.25 to 75 kW, with 2, 4 or 6 poles, in sizes 71, 80, 90, 100, 112, 132, 160, 180, 225 and 280. The same tables mark the DRS types in sizes 71 and 80 (and DRS180LC4, DRS225MC4) as a phased-out series, and the others as the current series; all are permitted only as replacements in accordance with the regulation. In the same power and pole block, the tables show the DRN (IE3) motor from the current series.
For a quotation request for a motor or gear motor with DRS, send the complete nameplate code (for example DRS71M4, together with any suffixes), the voltage, the frequency, the mounting design (feet or flange) and, if present, the brake and the temperature sensor. On that basis we confirm the matching DRN motor, with the dimensions that matter for replacement: the document shows that the length LB, the outer dimension AC of the fan cover and the shaft height H can differ between a DRS type and the DRN type in the same block.
Models and codes
| Code | Note |
|---|---|
| DRS 71S 6 | 0.25 kW, 6 poles, 895 min⁻¹, efficiency at 100 % of rated power 62.2 % (IE1); in the same block, DRN71M6 (IE3): 915 min⁻¹, 68.6 %. |
| DRS 71S 4 | 0.37 kW, 4 poles, 1380 min⁻¹, efficiency at 100 % of rated power 66.6 % (IE1); in the same block, DRN71M4 (IE3): 1415 min⁻¹, 77.3 %. |
| DRS 71M 2 | 0.55 kW, 2 poles, 2810 min⁻¹, 72.9 %, shaft height H 80 mm; in the same block, DRN71M2 (IE3): 2825 min⁻¹, 77.8 %, H 71 mm. |
| DRS 71M 4 | 0.55 kW, 4 poles, 1360 min⁻¹, 70.6 %, LB 223 mm; in the same block, DRN80MK4 (IE3): 1435 min⁻¹, 80.8 %, LB 241 mm. |
| DRS 80S 4 | 0.75 kW, 4 poles, 1400 min⁻¹, 75.3 %; in the same block, DRN80M4 (IE3): 1440 min⁻¹, 82.9 %. |
| DRS 80M 4 | 1.1 kW, 4 poles, 1410 min⁻¹, 77 %, H 90 mm; in the same block, DRN90S4 (IE3): 1455 min⁻¹, 84.5 %. |
| DRS 90L 4 | 2.2 kW, 4 poles, 1400 min⁻¹, 81.1 %, H 100 mm; in the same block, DRN100LS4 (IE3): 1450 min⁻¹, 86.9 %. |
| DRS 132M 4 | 7.5 kW, 4 poles, 1445 min⁻¹, 87.1 %; in the same block, DRN132M4 (IE3): 1468 min⁻¹, 90.4 %. |
Key specifications
| Efficiency class of the DRS types in the comparison table | IE1 |
|---|---|
| DRS sizes in the comparison table | 71, 80, 90, 100, 112, 132, 160, 180, 225, 280 |
| Number of poles in the comparison table | 2, 4, 6 |
| DRS rated powers in the comparison table, total | 0.25–75 kW |
| DRS rated powers, 2 poles | 0.55–7.5 kW |
| DRS rated powers, 4 poles | 0.37–75 kW |
| DRS rated powers, 6 poles | 0.25–7.5 kW |
| Data compared in the document, per type | rated speed, efficiency at 100 % of rated power, rated current, starting ratio Ia/In, moment of inertia, LB (length from the flange to the end of the fan cover), LBS (for the brake motor), AC (outer dimension of the fan cover), H (shaft height) |
| DRS motors with two rated speeds (outside the comparison table) | 4/2, 8/4, 8/2 and 12/2 poles |
The document "Energy Efficiency according to regulation (EU) 2019/1781 – Comparison of technical data and dimensions on AC motors" (16 pages, from the official SEW-EURODRIVE documentation server) marks the DRS types in sizes 71 and 80, as well as DRS180LC4 and DRS225MC4, as "Phased-out motor series", and the other DRS types, in sizes 90–280, as "Current motor series"; all are permitted only as replacements under the regulation. For the same power and number of poles, the document compares them with DRN (IE3) motors, marked as the current series.
Frequently asked questions
Is DRS still in the current SEW-EURODRIVE range?
The official comparison document marks the DRS types in sizes 71 and 80 (and DRS180LC4, DRS225MC4) as "Phased-out motor series", and the other DRS types as "Current motor series"; all are permitted only as replacements under Regulation (EU) 2019/1781, and the DRN (IE3) motors appear as the current series. The document states that, after 1 July 2021, motors that do not meet the requirements of the regulation can be supplied only as a replacement for a previously supplied motor or for repair, and that the manufacturer tracks spare parts availability for 10 years.
What replaces a DRS motor?
In each power and pole-number block, the official document places the DRS type next to the DRN (IE3) motor, for example DRS71S4 (0.37 kW, 4 poles) next to DRN71M4. The size does not always stay the same: at 0.55 kW and 4 poles, DRS71M4 sits next to DRN80MK4, with LB 223 mm versus 241 mm. For mounting, we check LB, AC and H against the nameplate code before the quotation.
What data do I send for a quotation?
The complete nameplate code (including suffixes), the voltage, the frequency, the number of poles, the mounting design (feet or flange) and, if present, the brake and the temperature sensor. When the item is in stock, locally or at the supplier, delivery takes 24–72 h; to order, typically 1–4 weeks.
Other SEW Eurodrive series
The data come from the comparison tables by power step in the official document, for DRS with 2, 4 and 6 poles; for DRS motors with two rated speeds and for mounting dimensions outside those compared, we confirm them for the exact code before the quotation.
Updated: 2026-11-23

