Sodeca supplier in Romania
From the Sodeca range we quote SVE and SVE/PLUS ducted centrifugal fans, CBD and CBX centrifugal fans and CJTHT smoke extraction fans; from the model code on the nameplate we find the exact variant.
Who is Sodeca and what does it make?
Sodeca produces industrial fans and smoke extraction systems in Spain, with 8 production centres of its own and sales subsidiaries on five continents, according to company data. The range covers ducted centrifugal fans (SVE, SVE/PLUS, NEOLINEO, NEOSILENT), direct-drive or belt-driven centrifugal fans for low-medium-high pressures (CBD, CBX, CDXR, CMR, CA), smoke extraction fans for temperatures of 300-400°C (CJTHT) and pressurisation systems for escape stairs (KIT BOXPDS).
What distinguishes the range is the availability of exact parameters for each model: for example the SVE/PLUS-100/L variant runs at 1800 rpm and delivers 290 m³/h, while the SVE/PLUS-400/H reaches 2310 m³/h at 1350 rpm, both with 40 mm sound-absorbing insulation. On the direct-drive centrifugal side, a 3/4 HP CBD-2525-4M model delivers 3600 m³/h at 1310 rpm. Sodeca is certified ISO 9001:2015 and ISO 14001 by Bureau Veritas.
For the Romanian market, the range is relevant for smoke extraction systems in commercial and industrial spaces, where a fan certified for operation at high temperature for a minimum of 2 hours is required, and for ventilation units where the published parameters (flow, speed) allow precise sizing before ordering.
What do we supply from the Sodeca range?
| Product | Description |
|---|---|
| SVE/PLUS Series Ducted Fans | In-line centrifugal fans with 40 mm sound-absorbing insulation in the casing, available in sizes from SVE/PLUS-100 (1800 rpm, 290 m³/h) to SVE/PLUS-400 (1350 rpm, 2310 m³/h). The EW variants use EC motors for low consumption, and CPC adds constant pressure control for systems with variable pressure loss. Typical application: ducted ventilation in commercial buildings where noise transmitted through the duct must be limited. |
| CBD/CBX/CDXR Series Centrifugal Fans | Centrifugal fans with direct drive (CBD) or belt drive (CBX, CDXR), with double or single inlet, for low-medium pressures. A concrete example: the 3/4 HP CBD-2525-4M delivers 3600 m³/h at 1310 rpm, while the 3 HP CBD-3939-6T reaches 11,400 m³/h at 890 rpm. Typical application: general ventilation of industrial halls and extraction of stale air from large commercial spaces. |
| CJTHT Series Smoke Extraction Fans | Axial fans certified for operation at high temperatures, in the 400°C/2 hours and 300°C/2 hours classes, also available in an ATEX (3G) version for explosive atmospheres. Used in smoke extraction systems in car parks, commercial atriums and industrial halls, where the fire safety regulation requires certified operation for the duration of the evacuation of people. Installation requires checking compatibility with the building's fire safety design. |
Why Sodeca?
- Technical parameters published per model (flow, speed, noise level), not only per product family
- ISO 9001:2015 and ISO 14001 certification from Bureau Veritas
- A dedicated series for smoke extraction at 300-400°C for a minimum of 2 hours (CJTHT)
- 8 production centres of its own and 13 subsidiaries on five continents, according to company data
- Separate ranges for medium pressure (CMP, CMR) and high pressure (CA), for precise sizing
Which Sodeca codes and series are requested most often?
| Code | Description |
|---|---|
| SVE | Ducted centrifugal fan, acoustic insulation |
| SVE/PLUS | Ducted fan, 40 mm insulation |
| SVE/PLUS-100/L | 1800 rpm, 290 m³/h |
| SVE/PLUS-400/H | 1350 rpm, 2310 m³/h |
| NEOLINEO/V | Ducted fan, detachable body |
| NEOSILENT | Ducted fan, low noise |
| CBD-2525-4M | 3/4 HP, 1310 rpm, 3600 m³/h |
| CBD-3939-6T | 3 HP, 890 rpm, 11,400 m³/h |
| CBX | Belt-driven centrifugal fan, double inlet |
| CDXR | Belt-driven centrifugal fan, backward-curved blades |
| CSXR | Centrifugal fan, single inlet, belt-driven |
| CMR | Centrifugal fan, medium pressure, heavy-duty construction |
| CMP | Centrifugal fan, medium pressure |
| CA | Centrifugal fan, high pressure |
| CAB | Centrifugal fan, high pressure, single inlet |
| CJTHT | Axial smoke extraction fan, 400°C/2h or 300°C/2h |
| CJTHT/ATEX | Smoke extraction fan, version for ATEX zones |
| KIT BOXPDS | Pressurisation system for the escape route |
| TUB | Ducted fan for high temperatures, 250°C |
Where is Sodeca equipment used?
- Fire safety: smoke extraction and pressurisation of escape stairs
- Commercial buildings: ducted ventilation with controlled noise level
- Industrial halls: general ventilation and extraction of stale air
- Car parks: smoke extraction and routine ventilation
- Explosive atmospheres: ATEX fans for classified zones
How do we supply Sodeca in Romania?
We work with the Sodeca range on the basis of the manufacturer's technical documentation; we confirm stock and lead time in the quotation. We bring in the fans to order through supply channels in Spain and the EU, usually in 1–4 weeks from order confirmation. For an accurate quotation we need: the air flow required (m³/h), the available static pressure, whether the application is smoke extraction (with the temperature and duration required by the regulation) and the duct connection size. We do not keep this range on the shelf; we check current availability with the manufacturer before confirming the lead time with the customer.
The design of the building's fire safety system and the ISU (emergency situations inspectorate) approval for the smoke extraction installation remain the responsibility of the specialist designer.
Frequently asked questions about Sodeca
What operating regime do the motors of the Sodeca CJTHT smoke extraction fans have?
The CJTHT/ATEX axial fans have class H motors for continuous S1 duty and S2 emergency duty, that is at 300 °C or 400 °C for 2 hours. In S1 duty the temperature of the air handled is between -20 and +40 °C, and up to 50 °C for hot climates. The motors have ball bearings and IP55 protection, and the series has ATEX 3G certification for zone 2.
How do I choose a Sodeca fan by flow parameters?
For each model Sodeca publishes the speed and the flow at the duty point, for example the SVE/PLUS-100/L delivers 290 m³/h at 1800 rpm. The correct choice compares the flow and pressure required by the installation with the model's curve, not only with the casing size.
What is the equivalent of the Sodeca CJTHT series?
CJTHT is a series of axial fans certified for smoke extraction at 400°C or 300°C for 2 hours. Equivalence depends on the specific certification required by the fire safety design.
What lead time do you offer in Romania for Sodeca fans?
For Sodeca, delivery depends on the model: to order, usually 1–4 weeks, through the manufacturer's European subsidiaries. For certified smoke extraction series, such as CJTHT, the lead time is confirmed only after we check the exact availability of the variant required by the design.
What information do you need for a quotation for a Sodeca smoke extraction fan for a hall or car park?
The air flow required, the temperature and operating duration required by the fire safety regulation, the connection size and whether the zone is ATEX classified. With these details we identify the suitable model from the CJTHT series for subsequent technical evaluation.
How do I request a Sodeca quotation?
Send the Sodeca code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 12 November 2026 · Sources: Sodeca (manufacturer documentation)