For SPX Cooling Technologies we quote Marley NC and MD cooling towers, MH, LW and DT closed-circuit coolers, DTC evaporative condensers and spare parts, based on the model on the nameplate and the thermal data of the installation.

Headquarters: Overland Park, Kansas, USA

Request a quote

Who is SPX Cooling Technologies and what does it make?

SPX Cooling Technologies, also known as SPX Cooling Tech, is based in Overland Park, Kansas, and builds cooling towers, closed-circuit evaporative coolers, evaporative condensers, industrial evaporators and air-cooled heat exchangers. The Marley name, under which most of the products appear, is now a century old, and the company also has an international network of offices and subsidiaries.

A unit of this kind sits on a roof or next to a chilled-water plant, at a refrigeration installation or on a process line with cooling water. Towers are divided by flow type (counterflow or crossflow), by forced or natural draft and by the plume-abatement version, and each model has a name such as Marley NC, MD, AV, Aquatower, Series 10 or Recold JT. The closed-circuit coolers are the Marley MH, LW and DT series, and Recold JW and MW.

On the refrigeration side, the evaporative condensers include Marley DTC, Recold JC, LC and MC, as well as SGS IEC and SGS DTC, while the industrial evaporators comprise the SGS DT-DTX, BTR, PC, CF Series II and FL cooling units. The parts programme covers gearboxes, motors and drives, fans, couplings and drive shafts, fill and drift eliminators, nozzles and valves, plus parts for towers of other makes.

What do we supply from the SPX Cooling Technologies range?

ProductDescription
Marley cooling towersTowers with counterflow or crossflow, forced or natural draft, under names such as NC Everest, NC, MD, AV, Aquatower, Series 10 and 15, Marley 800 Natural Draft or round hybrid, plus the ClearSky and PPWD plume-abatement versions.
Closed-circuit evaporative coolersThe Marley MH, LW and DT series, and Recold JW and MW, for cooling a process fluid in a closed circuit, with no contact between the fluid and the spray water, which protects the process circuit from impurities.
Evaporative condensers and evaporatorsMarley DTC, Recold JC, LC and MC, SGS IEC and DTC condensers, plus SGS DT-DTX, BTR, PC, STC industrial evaporators and CF Series II and FL centrifugal units, used in industrial refrigeration installations.
Tower parts and componentsGearboxes, motors and drives, fans, couplings and drive shafts, fill and drift eliminators, nozzles and valves, control systems and SGS parts for refrigeration units, including for towers of other makes.

Why SPX Cooling Technologies?

  • Coverage across tower types — counterflow, crossflow, forced or natural draft and hybrid versions for plume abatement
  • Closed-circuit coolers — Marley MH, LW, DT and Recold JW, MW, for installations where the process fluid must not touch open water
  • Evaporative condensers for refrigeration — Marley DTC, Recold JC, LC, MC and SGS IEC, DTC, used in industrial installations with refrigerant
  • Parts for existing towers — gearboxes, fans, couplings, fill, drift eliminators, nozzles and valves, including for towers of other makes
  • CTI (Cooling Technology Institute) noise certification — for cases where the tower is installed next to occupied buildings or noise-sensitive areas

Which SPX Cooling Technologies codes and series are requested most often?

CodeDescription
Marley NCCooling tower
Marley NC EverestCooling tower
Marley MDCooling tower
Marley AVCooling tower
Marley AquatowerCooling tower
Marley Series 10 / 15Cooling towers
Recold JTCooling tower
Marley MHClosed-circuit evaporative cooler
Marley LWClosed-circuit evaporative cooler
Marley DTClosed-circuit evaporative cooler
Recold JW / MWClosed-circuit evaporative coolers
Marley DTCEvaporative condenser
Recold JC / LC / MCEvaporative condensers
SGS IEC / DTCIndustrial evaporative condensers
SGS DT-DTXCooling unit (industrial evaporator)
SGS CF Series IICentrifugal cooler

Where is SPX Cooling Technologies equipment used?

  • HVAC and industrial buildings — towers on the chilled-water circuit
  • Industrial refrigeration — SGS evaporative condensers and evaporators
  • Industrial processes — closed-circuit coolers for process fluids
  • Data centres — evaporative cooling solutions for the water circuit
  • Noise-sensitive areas — towers with CTI-certified sound performance

How do we supply SPX Cooling Technologies in Romania?

We can quote cooling towers, closed-circuit coolers, evaporative condensers and parts for existing SPX Cooling units. Supplied to order; usually 1–4 weeks for parts, while for towers and refrigeration units the lead time can be longer, depending on the specification. For a quotation we need the model on the unit nameplate, the thermal capacity, the water flow, the inlet and outlet temperatures, the design wet-bulb temperature and, for parts, the part number or a photo.

Parts for old towers or for other makes can be identified only from the model, the dimensions and a photo of the component.

Frequently asked questions about SPX Cooling Technologies

What does SPX Cooling Technologies make?

The American company from Overland Park builds cooling towers, closed-circuit evaporative coolers, evaporative condensers, SGS industrial evaporators and air-cooled exchangers, most of them under the Marley brand, plus spare parts for towers, including components for SGS refrigeration units.

How do I choose between an open tower and a closed-circuit cooler?

An open tower cools the water directly by evaporation, while a closed-circuit cooler keeps the process fluid in a coil, with no contact with the spray water. Tell us the fluid, the temperatures, the capacity in kW and the cleanliness requirements of the circuit, and we will point you to the right family.

Can you supply SPX towers and parts in Romania, and how quickly?

Yes, we can supply SPX Cooling Technologies items to order. Common parts usually take 1–4 weeks; towers and refrigeration units, being configured equipment, can have a longer lead time, which we confirm in the quotation once we receive the model and the thermal data.

Can you identify a part for an old Marley tower?

We try, based on the tower model, the year of installation and a photo of the part: gearbox, fan, fill, nozzles or drift eliminators. We establish the equivalence from the dimensions and the photos; we check before quoting, so that we do not quote a part that does not fit.

What data should I send for a quotation on an evaporative condenser?

Send the refrigerant, the condensing load, the condensing temperature, the design wet-bulb temperature, the installation site and, if you are replacing a unit, the model on the nameplate. Also state the working pressure and the space available for installation.

How do I request a SPX Cooling Technologies quotation?

Send the SPX Cooling Technologies code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: SPX Cooling Tech, LLC (manufacturer documentation)