TA Instruments supplier in Romania
For TA Instruments we quote DHR and DCR rheometers, DSC 250 and 2500 calorimeters, TGA 550 and 5500 analysers, SDT 650, DMA 850 and RPA, MDR one and MV one instruments; we need the material, the temperature range and the test standard.
Headquarters: New Castle, Delaware, USA
Who is TA Instruments and what does it make?
TA Instruments is an American manufacturer based in New Castle, Delaware, of instruments for thermal analysis, rheology, calorimetry and materials testing, used in laboratories for polymers, elastomers, lubricants and advanced materials. From the range we quote the rheometers, thermal analysers, dilatometers and rubber testing instruments; the other TA Instruments lines are outside our offer. For a quality control laboratory, what matters is the repeatability of the measurement, from flow behaviour to the transition or decomposition temperature of a material.
Rotational rheometers are the central family. The Discovery Hybrid Rheometer (DHR) has a magnetic bearing for low torque and more than 200 accessories with SmartSwap quick change, the Discovery Core Rheometer (DCR) is designed for routine work, with a touchscreen, and the ARES-G3 has a separate motor and transducer, for research in polymer rheology. Thermal analysis includes the differential scanning calorimeters (DSC) Discovery X3, DSC 2500, DSC 250, DSC 25, DSC 25L and DSC 25P, for pressure, the thermogravimetric analysers (TGA) 55, 550 and 5500, the simultaneous analyser SDT 650, the dynamic mechanical analyser DMA 850 and the dilatometers DIL 801, 802, 805, 806 and 820. For rubber there are the RPA process analyser, the moving die rheometer MDR one and the Mooney viscometer MV one, for vulcanisation curves and Mooney viscosity.
The methods follow ASTM standards, for example D3418 for polymer transitions by DSC and D6375 for the evaporation loss of oils by TGA. A quotation starts from the model of the instrument, where an existing laboratory is being completed, or from the type of material, the temperature range and the test standard, for a new project.
What do we supply from the TA Instruments range?
| Product | Description |
|---|---|
| Discovery Hybrid (DHR), Discovery Core (DCR) and ARES-G3 rheometers | The DHR uses a magnetic bearing and a dual-read optical encoder, with quick change of geometries. The DCR combines viscosity and viscoelasticity measurement with the RheoGuide touchscreen interface. The ARES-G3 has a separate motor and transducer, for research into polymer behaviour. |
| DSC calorimeters (Discovery X3, DSC 2500, DSC 250, DSC 25, DSC 25P) | Differential scanning calorimeters for thermal transitions, melting and crystallisation enthalpies, and oxidative induction time in polyolefins. The X3 works with several samples, and the DSC 25P is the pressure version. |
| TGA, SDT and DMA analysers and dilatometers | TGA 55, 550 and 5500 measure the change in mass with temperature, time and atmosphere; the 5500 has an infrared furnace. The SDT 650 performs TGA and DSC simultaneously, the DMA 850 measures dynamic mechanical properties, and the DIL 801–820 dilatometers measure thermal expansion. |
| Rubber testing (RPA, MDR one, MV one) | The RPA analyses the rheological behaviour of elastomers and rubber compounds, including vulcanisation curves. The MDR one is a rotorless cure meter with sealed biconical dies, and the MV one measures Mooney viscosity, pre-vulcanisation time (scorch) and stress relaxation. |
Why TA Instruments?
- Rheometers for all levels — DCR for routine work, DHR for the laboratory, ARES-G3 for research, with more than 200 SmartSwap accessories on the DHR
- Thermal analysis in a wide range of models — DSC, TGA, SDT, DMA and dilatometers, covering transitions, decomposition and expansion
- Rubber testing — RPA, MDR one and MV one measure vulcanisation, Mooney viscosity and stress relaxation
- Methods in line with standards — ASTM D3418, D3895 and D6375, among others, for polymers and lubricants
- Pressure DSC version — DSC 25P for tests under pressure, alongside the multi-sample Discovery X3
Which TA Instruments codes and series are requested most often?
| Code | Description |
|---|---|
| DHR | Discovery hybrid rheometer, with magnetic bearing |
| DCR | Discovery Core rheometer for routine work |
| ARES-G3 | Research rheometer with separate motor and transducer |
| Discovery X3 DSC | Multi-sample differential calorimeter |
| DSC 2500 | Differential scanning calorimeter |
| DSC 250 | Differential scanning calorimeter |
| DSC 25 | Differential scanning calorimeter |
| DSC 25P | Pressure differential calorimeter |
| TGA 55 | Thermogravimetric analyser |
| TGA 550 | Thermogravimetric analyser |
| TGA 5500 | Thermogravimetric analyser with infrared furnace |
| SDT 650 | Simultaneous TGA and DSC thermal analyser |
| DMA 850 | Dynamic mechanical analyser |
| DIL 805A | Dilatometer |
| MDR one | Moving die rheometer for rubber |
| MV one | Mooney viscometer |
Where is TA Instruments equipment used?
- Polymers and plastics — thermal transitions, flow and oxidative induction time
- Rubber industry — vulcanisation, Mooney viscosity and compound analysis
- Lubricants and petroleum products — evaporation loss and thermal stability
- Materials and ceramics — dilatometry and simultaneous thermal analysis of samples
- Quality control laboratories — batch checks based on ASTM standards
How do we supply TA Instruments in Romania?
We can quote TA Instruments instruments from the DHR, DCR, ARES-G3, DSC, TGA, SDT, DMA families, dilatometers and rubber instruments, as well as accessories and consumables for them. We supply them to order, usually in 1–4 weeks; depending on the specification, the lead time can be longer for instruments configured with accessories. For a correct quotation, send us the materials to be tested, the temperature range, the standards to be followed, the number of samples per day and, for completing a laboratory, the model of the existing instrument and the accessories already in use.
The instrument or configuration is recommended once we know the materials to be tested and the standards you follow.
Frequently asked questions about TA Instruments
What instruments does TA Instruments make?
TA Instruments makes rotational rheometers, differential scanning calorimeters, thermogravimetric analysers, dynamic mechanical analysers, dilatometers and rubber testing instruments. The company is based in New Castle, in Delaware, and its instruments serve materials and quality control laboratories.
How do I choose between DSC, TGA and an SDT simultaneous analyser?
DSC measures the heat flow of transitions, TGA the change in mass, and SDT performs both measurements on the same sample. The choice depends on the material and on the laboratory's question, for example melting, moisture or decomposition. Send us the materials, the temperature range and the standard to be followed.
Do you supply TA Instruments instruments in Romania, and how quickly?
Yes, we can supply TA Instruments items to order. Accessories can ship in 24–72 h when the item is in stock, locally or at the supplier. Configured instruments may take longer, depending on the specification; we confirm the lead time in the quotation.
Can an older rheometer be completed or replaced with a current model?
This is checked against the existing model, the accessories and the software used. We establish the compatibility of geometries and methods on the basis of this data; send us the model, the approximate year and the list of accessories, and we will show what can still be used on a current series.
What data do I need to send for a quotation on a thermal analysis or rheology instrument?
Send the materials to be tested, the temperature range, the working atmosphere, the standards to be followed, the sample volume per day and the accessories wanted, for example an automatic sample feeder or geometries. For completing a laboratory, add the model of the existing instrument.
How do I request a TA Instruments quotation?
Send the TA Instruments code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: TA Instruments (manufacturer documentation)