TROX supplier in Romania

For TROX we quote filter elements and cells of the MFI, MFC, MFP and MFPCR families, housings for HEPA filters KSF, KSFS and DCA, and FKR-EU and FKRS-EU circular fire dampers; the item is determined by filtration class, dimensions and installation.

Founded in 1951 · Headquarters: Neukirchen-Vluyn, Germany

Request a quote

Who is TROX and what does it make?

TROX is a German manufacturer of ventilation and air conditioning components, based in Neukirchen-Vluyn, active since 1951. For industrial and technical applications two families matter: air filtration, with mini-pleat filter elements and cells, and fire protection of air ducts, with fire dampers. The range also includes air distribution components and air handling units.

Mini-pleat filters are made in the groups ISO ePM10, ISO ePM1, EPA and HEPA. MFI is a filter insert for pre-filtration or final filtration, with an optional ATEX version for zones 1, 2, 21 and 22. MFC is a filter cell with dimensions of, for example, 610 × 610 × 292 mm, with a frame of galvanised steel (GAL) or stainless steel (STA), for temperatures of up to 80 °C. MFP are filter panels, MFPCR are HEPA and ULPA panels for clean rooms, and FHD are final panels with a hood, in classes E11, H13, H14 and U15. MFC cells are mounted in HEPA housings of the types KSF, KSFS and DCA.

The FKR-EU circular fire dampers, in nine nominal sizes between 315 and 800 mm, and FKRS-EU, in ten sizes between 100 and 315 mm, separate two fire compartments. They are tested to EN 1366-2 and classified up to EI 120 under EN 13501-3, with release at 72 or 95 °C. For a quotation the filtration class and the frame dimensions or the nominal duct size matter.

What do we supply from the TROX range?

ProductDescription
MFI and MFC filter inserts and cellsMini-pleat filters for pre-filtration or final filtration, in classes ISO ePM10, ISO ePM1, EPA and HEPA. MFC has a GAL or STA frame, works up to 80 °C and is mounted in KSF, KSFS or DCA HEPA housings.
MFP, MFPCR and FHD filter panelsMFP fits the TFC, TFW, TFM, KSF, KSFS and DCA units. MFPCR and FHD are HEPA and ULPA panels for clean rooms, operating theatre ceilings and fan filter units, in classes from E11 to U15 (FHD) and from H13 to U16 (MFPCR).
FKR-EU fire dampersLarge circular fire damper for sealing duct penetrations between two fire compartments, in nine sizes between 315 and 800 mm, with release at 72 or 95 °C and classification up to EI 120.
FKRS-EU fire dampersCompact version for small diameters, between 100 and 315 mm, in ten sizes, with a casing length of 400 mm, classified from EI 30 to EI 120 and release by fusible link at 72 or 95 °C.

Why TROX?

  • Mini-pleat filters from ePM10 to HEPA and ULPA — a single family covers pre-filtration and final filtration
  • MFC cells compatible with KSF, KSFS and DCA housings — the filter is replaced without changing the housing
  • ATEX version for MFI, zones 1, 2, 21 and 22 — the filter can be used in areas with explosive dust or gases
  • MFPCR and FHD panels for clean rooms — classes H13, H14 and U15
  • FKR-EU and FKRS-EU fire dampers tested to EN 1366-2 — they separate fire compartments on circular ducts

Which TROX codes and series are requested most often?

CodeDescription
MFIMini-pleat filter insert, ePM10 – HEPA
MFCMini-pleat filter cell, GAL or STA frame
MFPFilter panel, pre- or final filtration
MFPCRHEPA and ULPA panel for clean rooms
MFEMini-pleat filter element
FHDFinal panel with hood, E11 – U15
KSFHousing for HEPA filters, duct mounting
KSFSHousing for HEPA filters, duct mounting
DCAHousing for HEPA filters
FKR-EULarge circular fire damper, 315–800 mm
FKRS-EUSmall circular fire damper, 100–315 mm

Where is TROX equipment used?

  • Pharmaceutical production and clean rooms — HEPA and ULPA filters
  • Research and nuclear engineering — final filtration with MFP panels
  • Industrial ventilation and technical buildings — ePM10 and ePM1 pre-filters
  • Buildings with fire compartments — fire dampers on circular ducts

How do we supply TROX in Romania?

We can quote TROX mini-pleat filters, HEPA panels, filter housings and circular fire dampers. For a correct quotation send the type or code from the filter or damper, the frame dimensions or the nominal duct diameter, the filtration class wanted, the temperature and, for dampers, the fire resistance class required. We order filters and dampers, in a usual interval of 1–4 weeks. Special dimensions or versions may need more time, and the exact date is stated in the quotation.

FKR-EU fire dampers are not intended for smoke control or commercial kitchens, so we check the use before confirming the quotation.

Frequently asked questions about TROX

What are MFI, MFC, MFP and FKR-EU in the TROX range?

TROX makes, in Neukirchen-Vluyn, Germany, mini-pleat filters (MFI inserts, MFC cells, MFP, MFPCR and FHD panels), housings for HEPA filters and FKR-EU and FKRS-EU circular fire dampers, in addition to air distribution components. The company has existed since 1951.

How do I choose the filtration class between ePM1 and HEPA?

ePM10 and ePM1 filters are for pre-filtration or final filtration in ventilation and air conditioning, while EPA and HEPA, for example E11, H13 and H14, are for production, research, pharmaceuticals and areas with high cleanliness requirements. Send the class wanted and the dimensions, and we check the version.

Do you supply TROX in Romania and how fast?

Yes. TROX filters and dampers are ordered through us and usually arrive in 1–4 weeks. An existing item can ship in 24–72 h when the item is in stock, locally or at the supplier. For special dimensions the lead time can be longer.

Can I replace an existing filter with an MFC or MFI?

It is possible if the frame dimensions and the class are compatible with the housing. The width and depth of an MFC cell cannot be changed, only the height. Send the dimensions, the class of the current filter and the housing type, and we check whether there is a suitable cell.

What data do you need for an FKR-EU or FKRS-EU fire damper?

For FKR-EU or FKRS-EU send the nominal duct diameter, the connection type (with spigot or with flange), the fire resistance class required, the release temperature (72 or 95 °C) and the type of actuation, with fusible link or with servo motor.

How do I request a TROX quotation?

Send the TROX code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 21 November 2026 · Sources: TROX SE (manufacturer documentation)