Vector Informatik supplier in Romania
For Vector Informatik we quote hardware interfaces from the VN1610, VN1630A, VN1641, VN1670, VN1530 and VN8900 families; for a quotation we need the full code, the number of channels, the bus type and the way it connects to the computer.
Founded in 1988 · Headquarters: Stuttgart, Germany
Who is Vector Informatik and what does it make?
Vector Informatik is a German company headquartered in Stuttgart, active since 1988, which offers the automotive, rail and agricultural industries tools for developing, testing and diagnosing communication networks. Only the network hardware interfaces are in the offer, that is, the devices that connect a computer to CAN, CAN FD, CAN XL and LIN buses or to an Ethernet connection; software licences are outside our offer.
The basic family is VN1600, connected to the computer through USB. The VN1610 and VN1611 have two channels, the VN1630A and VN1640A have four channels with slots for transceiver modules, the VN1630 log records data on an SD/SDHC card of up to 32 GB, and the VN1641 adds CAN XL and a host connection through USB 3 or 1000BASE-T Ethernet. The VN1670 groups 15 channels in a metal housing, with USB 3.2 Gen 1 through a Type C connector and Ethernet. For computers with PCIe slots there are the VN1530 and VN1531, for real-time stations the VN8900, and the VN1150 connects to the computer through Ethernet.
A maintenance or commissioning engineer turns to such interfaces when they need to read traffic on a bus, simulate missing nodes or programme and diagnose control units. CAN and LIN buses are found on vehicles, mobile machinery and test benches, and the quotation starts from the number of channels, the bus type and the operating system of the host computer.
What do we supply from the Vector Informatik range?
| Product | Description |
|---|---|
| VN1610 and VN1611 | Compact two-channel interfaces for CAN, CAN FD and LIN, integrated with inputs and outputs, connected through high-speed USB 2.0. The VN1610 has a plastic housing of 65 × 42 × 20 mm and needs no external power supply. |
| VN1630A, VN1630 log and VN1640A | Four-channel interfaces with variable slots for CAN FD, LIN, J1708 or K-Line transceiver modules. The VN1630 log adds recording on an SD/SDHC card and a 6–50 V external supply for mobile measurements without a computer. |
| VN1641 and VN1670 | Interfaces for CAN, CAN FD and CAN XL; the VN1641 has four channels and a USB 3 or 1000BASE-T Ethernet connection, and the VN1670 has 15 channels and a metal housing. Both synchronise time through a cable or through IEEE 1588. |
| VN1530, VN1531, VN8900 and VN1150 | Interfaces for other computer architectures: VN1530 and VN1531 on PCIe, VN8900 for real-time stations through USB or Ethernet, VN1150 through Ethernet with CAN, CAN FD, LIN and sensor inputs. |
Why Vector Informatik?
- VN1600 family from two to 15 channels — from the VN1610, with two channels, to the VN1670, with five D-SUB15 HD connectors
- CAN XL in the same family — the VN1641 and VN1670 cover CAN, CAN FD and CAN XL, with CAN XL speeds up to 20 Mbit/s
- Standalone logging — the VN1630 log saves CAN, CAN FD and LIN traffic on an SD/SDHC card of up to 32 GB, without a connected computer
- Integrated inputs and outputs — the VN1630A has one 0–18 V analogue input, two digital inputs and one digital output
- Precise time synchronisation — time stamping with 1 µs resolution, and the VN1641 and VN1670 can synchronise through IEEE 1588 (PTP)
Which Vector Informatik codes and series are requested most often?
| Code | Description |
|---|---|
| VN1610 | Two-channel CAN/CAN FD and LIN interface, USB 2.0 |
| VN1611 | Two-channel interface, on two D-SUB connectors |
| VN1630A | Four-channel interface with two transceiver slots |
| VN1630 log | Interface with recording on an SD/SDHC card |
| VN1640A | Four-channel interface with four transceiver slots |
| VN1641 | CAN XL interface with USB 3 or 1000BASE-T Ethernet |
| VN1670 | 15-channel interface, USB 3.2 Gen 1 Type C and Ethernet |
| VN1530 | PCIe interface for CAN, CAN FD, CAN XL, LIN |
| VN1531 | PCIe interface from the same VN15xx series |
| VN8900 | Interface for real-time stations, through USB or Ethernet |
| VN1150 | CAN/CAN FD and LIN interface connected through Ethernet |
Where is Vector Informatik equipment used?
- Automotive industry — CAN and LIN traffic analysis, diagnostics and programming of control units
- Mobile machinery — agricultural and construction, with CAN buses on the control units
- Rail vehicles — checking and simulating network nodes during commissioning
- Test benches — node simulation and data recording on CAN XL and Ethernet buses
How do we supply Vector Informatik in Romania?
We can quote the Vector hardware interfaces from the VN1600, VN1530, VN8900 and VN1150 families, but not the software licences. The devices are supplied to order, usually in 1–4 weeks, and can ship in 24–72 h when the item is in stock, locally or at the supplier. For a correct quotation, send the full code of the interface or of the one being replaced, the number of channels, the bus type (CAN, CAN FD, CAN XL, LIN), the way it connects to the computer (USB, PCIe or Ethernet) and the operating system used. The exact lead time is confirmed in the quotation.
Compatibility of an interface with a particular version of an analysis program or driver is confirmed once we have the operating system and the version of the application used.
Frequently asked questions about Vector Informatik
What network interfaces does Vector Informatik make?
Vector makes hardware interfaces that connect a computer to CAN, CAN FD, CAN XL and LIN buses: the USB VN1600 family, the VN1530 and VN1531 PCIe interfaces, the VN8900 for real-time stations and the VN1150 with an Ethernet connection. The company is headquartered in Stuttgart and has been working since 1988.
How do I choose between the VN1610, VN1630A and VN1670?
The choice starts from the number of channels and the working environment: the VN1610 has two channels and fits in a small housing, the VN1630A has four channels and slots for transceivers, and the VN1670 groups 15 channels with an Ethernet connection. Tell us how many buses must be read at the same time and what protocol they use.
Do you supply Vector interfaces in Romania and how fast?
Yes, for Vector Informatik, to order, usually in 1–4 weeks, or in 24–72 h when the item is in stock, locally or at the supplier. Depending on the specification, the lead time can be longer; the exact lead time appears in the quotation.
Can I replace an older interface with a model from the VN1600 series?
This can be checked: send the code of the old interface, the connector type, the version of the program used and the number of channels needed. On that basis we confirm whether a VN1610, VN1630A or another model covers the application, including the driver for your operating system.
What data should I send for a quotation on a Vector interface?
Send the code or series of the interface, the number of channels, the bus types (CAN, CAN FD, CAN XL, LIN), the way it connects to the computer, whether you need standalone recording on a card and the available supply voltage. With these we establish the suitable variant.
How do I request a Vector Informatik quotation?
Send the Vector Informatik code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: Vector Informatik GmbH (manufacturer documentation)