VibroSystM supplier in Romania
Air gap, flux and vibration sensors for hydro and turbo generators
Founded in 1986 · Headquarters: Longueuil, Canada
Who is VibroSystM and what does it make?
VibroSystM is a Canadian company based in Longueuil, in the province of Québec, founded in 1986. Its story begins in the 1980s, with the search for a solution to rubbing between rotor and stator in hydro generators. The result was capacitive air gap measurement technology, from which the company moved on to monitoring large hydro and turbo generators.
The technical theme is supervising a machine that costs a lot and is hard to repair. The ZOOM system collects data from air gap, magnetic flux, end-winding and stator bar vibration, displacement, absolute vibration and temperature sensors, through the ZPU-5000 and STATE-200 acquisition units. The VM3 and VM5 Airflow sensors have openings for cooling air and measure 1–20 mm, 2–20 mm or 2–42 mm. The MFP-100 (turbo generators) and MFM-100 (hydro generators) probes detect magnetic imbalances caused by inter-turn short circuits. The FOA-100/200 fibre-optic accelerometer measures end-winding vibration, while SBV-202 measures bar vibration in the slot; FOT-200 measures temperature through optical fibre.
For hydro and thermal power plants, the interest lies in upgrading the monitoring of existing generators and replacing obsolete sensors, especially where air gap or rotor flux measurement does not yet exist, because supervising these quantities prevents contact between rotor and stator.
What do we supply from the VibroSystM range?
| Product | Description |
|---|---|
| VM3 / VM5 Airflow — air gap sensors | Capacitive chains for measuring the rotor-stator air gap, with openings that let the cooling air pass through the sensor (VM3: 1–20 mm or 2–20 mm; VM5: 2–42 mm), covered by an American patent and easy to fit. |
| MFP-100 / MFM-100 — magnetic flux | Flux probes for turbo generators (MFP-100) and hydro generators (MFM-100), which track the field density and detect imbalances that lead to vibration, overheating and excessive stress on the rotor and stator. |
| FOA-100/200 and SBV-202 | Fibre-optic accelerometer for stator end-winding vibration, made of non-metallic materials, and capacitive sensor for stator bar vibration in the slot, immune to strong magnetic fields, both designed for measurements inside the electrical machine. |
| ZPU-5000 and STATE-200 | Acquisition units of the ZOOM monitoring system, mounted in instrumentation cabinets, which take the sensor signals and send them to the ZOOM server, with interfaces to SCADA, PLC and corporate networks. |
Why VibroSystM?
- Origin in capacitive air gap measurement — a technology developed for hydro generators and later extended to other large rotating machines
- Air gap sensors with openings for air — VM3 and VM5 Airflow do not block the stator ventilation holes
- Magnetic flux without removing the rotor — the MFP-100 and MFM-100 probes are fitted without removing the rotor or the poles
- Non-metallic materials at high voltage — the FOA fibre-optic accelerometer and the FOT temperature sensor are designed for end windings
- Integrated system — from sensors and cabinets to the ZOOM server
Which VibroSystM codes and series are requested most often?
| Code | Description |
|---|---|
| VM3 Airflow | Capacitive air gap sensor, 1–20 mm or 2–20 mm |
| VM5 Airflow | Capacitive air gap sensor, 2–42 mm |
| MFP-100 | Magnetic flux probe for turbo generators |
| MFM-100 | Magnetic flux probe for hydro generators |
| FOA-100 | Fibre-optic accelerometer for end windings |
| FOA-200 | Fibre-optic accelerometer for end windings |
| PCS-302 | Capacitive proximity probe |
| PES-110 | Eddy current proximity sensor |
| PES-302 | Sealed, oil-resistant proximity sensor |
| SBV-202 | Capacitive sensor for stator bar vibration |
| VSM797S | Piezoelectric accelerometer for absolute vibration |
| FOT-200 | Fibre-optic temperature sensor |
| ZPU-5000 | ZOOM system acquisition unit |
| STATE-200 | ZOOM system acquisition unit |
Where is VibroSystM equipment used?
- Hydro power plants — monitoring of air gap, flux and vibration of hydro generators
- Thermal power plants — monitoring of turbo generators, including end windings
- Monitoring upgrades — replacing obsolete sensors and acquisition units
- Large industrial rotating machines — extending monitoring to other machines
How do we supply VibroSystM in Romania?
We can quote VibroSystM air gap, magnetic flux and vibration sensors, acquisition units and accessories, depending on the type and dimensions of the generator. Supplied to order; usually 1–4 weeks, but for complete ZOOM systems, designed for the machine, the lead time is usually longer. For an accurate quotation send the machine type (hydro or turbo), the power, the core diameter and length, the number of poles or slots available for sensors, the quantities to be monitored and the existing monitoring system, if it is VibroSystM. The exact lead time is confirmed in the quotation.
The number and position of the sensors are established from the machine's construction drawings, and commissioning on the machine is outside our offer.
Frequently asked questions about VibroSystM
What product range does VibroSystM have?
VibroSystM, a Canadian company since 1986, makes sensors and monitoring systems for hydro generators and turbo generators: air gap, magnetic flux, end-winding and bar vibration, displacement, temperature, plus acquisition units and ZOOM software.
How do I choose between the VM3 and VM5 air gap sensor?
The measuring range guides the choice: VM3 Airflow covers 1–20 mm or 2–20 mm, and VM5 Airflow 2–42 mm. The nominal air gap of the machine and the mounting space on the stator matter. Send the inner diameter, the air gap and the machine type for a recommendation.
Can you supply VibroSystM products in Romania, and in what lead time?
Yes, to order. For sensors and accessories the order lead time is usually 1–4 weeks; complete ZOOM systems, designed for a machine, may take much longer and are confirmed in the quotation.
Can I replace an old air gap sensor with a VM Airflow?
It depends on the mounting and on the existing measuring chain, so a direct replacement is established from these data. Send the type of the current sensor, the range, the cable length and photos of the stator, to check whether a VM3 or VM5 fits.
What details should I send for a quotation on a generator monitoring system?
The machine type (hydro or turbo), the power and speed, the core dimensions, the quantities wanted (air gap, flux, end-winding vibration, temperature), the number of acquisition units and the interface to SCADA. If there is an old system, add the list of sensors.
How do I request a VibroSystM quotation?
Send the VibroSystM code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: VibroSystM Inc. (manufacturer documentation)