WIKA WIKA CPG1500
WIKA precision digital pressure gauge for on-site calibrations and pressure control.
The WIKA CPG1500 is a precision digital pressure gauge that combines the simplicity of a classic analogue gauge with the accuracy of a digital calibrator, used for on-site calibrations, service work and pressure checking in the oil and gas industry. The full order code describes, in order, the instrument version, the explosion protection, the unit of measurement, the pressure type, the measuring range, the process connection and the accuracy class (0.025%, 0.05% or 0.1% of span), so the label of an existing instrument already contains all the details needed for a quotation request.
From the CPG1500 range we can bring in new units to order from the European Union, in 1–4 weeks. For a correct quotation, the customer sends the desired pressure range, the accuracy class required, the type of process connection and whether the version for explosion-risk zones is needed; we confirm compatibility in the manufacturer's current data sheet before sending the quotation.
Models and codes
| Code | Note |
|---|---|
| CPG1500 (0…160 bar) | Standard gauge pressure range for service and ordinary calibration. |
| CPG1500 (0…1.500 psi) | Same instrument class, scaling in imperial units. |
| CPG1500 (abs. 0…40 bar) | Variant for measuring absolute pressure. |
| CPG1500-Ex | Version with protection for explosion-risk zones. |
Key specifications
| Measuring range, gauge pressure | 0…160 bar |
|---|---|
| Accuracy | 0.025 / 0.05 / 0.1 % of span |
| Display | 5 ½ digits, 7 segments |
| Power supply | 3 x 1.5 V, AA batteries |
| Battery life | 2.000–2.500 h |
| Protection | IP65 |
| Compensated temperature range | -10…+50 °C |
| Weight, without cover | approx. 680 g |
The manufacturer's data sheet (CT 10.51) contains no mention of withdrawal from production for the CPG1500.
Frequently asked questions
What information is needed for a quotation for the CPG1500 pressure gauge?
The desired pressure range, the accuracy class (0.025%, 0.05% or 0.1% of span), the type of process connection and, where applicable, the need for the explosion-protected version for explosion-risk zones. These data usually appear on the label of an existing instrument that is being replaced.
What do we check for each WIKA configuration?
We do not confirm from our own sources whether a particular configuration is still manufactured in exactly the same version; every time we check in the manufacturer's current data sheet. We do not promise availability from stock and we do not issue accredited calibration certificates ourselves.
How long does it take to bring in a CPG1500 to order?
Normally, bringing in a new unit from the European Union takes 1–4 weeks from order confirmation, depending on the exact configuration requested by the customer.