Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Atwood & Morrill supplier in Romania

FREE FLOW valves, check valves and Y-type valves for steam and turbines

Founded in 1900

Request a quote

Who is Atwood & Morrill and what does it make?

Atwood & Morrill is a brand of valves for steam and high-pressure water, born in 1900 in Salem, Massachusetts. It started with valves for factories, then supplied large valves for power plants, including for a prototype nuclear reactor. The problem it solves is turbine protection: on a trip, a valve with delayed closing lets steam or water from the heaters flow back into the turbine and can cause serious damage.

A typical product is the FREE FLOW reverse-flow valve, introduced in 1929 for extraction turbines. It has a free-swinging disc, an inclined seat for short stroke and an air cylinder that helps closing on the signal from the control room; it is supplied from 3 to 48 inches (80–1100 mm) and larger, in ASME classes 150–2500 and for temperatures up to 1200 °F. Alongside are check valves for cold reheat, for boiler feed water and for compressors, three-way valves, Y-type (globe) valves and forged parallel slide valves.

Such valves are found at thermal and cogeneration plants with extraction turbines, at nuclear power plants (main steam valves of the MSIV type) and at compressor stations. For a quotation, the diameter, the class, the temperature and whether the valve is fitted to an existing installation matter, because the face-to-face length and the cylinder interface must match.

What do we supply from the Atwood & Morrill range?

ProductDescription
FREE FLOW — reverse-flow valveValve for protecting extraction turbines: free-swinging disc, inclined seat, air cylinder for assisted closing, 3–48 inches and larger, ASME 150–2500, bodies in carbon steel, alloy steel, stainless steel or F91, to ASME B16.34.
Check valves for power plants and compressorsThe cold reheat check valve protects the high-pressure turbine from reverse flow; the boiler feed water check valve has dual-protection closing; the compressor check valve has assisted closing with an oil dashpot and a shaft bellows.
Y-type (globe), three-way and elbow valvesY-type valves for isolating steam and high-pressure water, in forged or cast versions; three-way valves with a cage-guided plug, with T-body; elbow-down valves for power plant applications.
Forged parallel slide valves and MSIVParallel slide valves from a single forging, for high pressures and temperatures; main steam isolation valves (MSIV) for nuclear power plants, with fast closing and tight sealing. Both are designed to ASME B16.34, and the MSIV also to ASME Section III.

Why Atwood & Morrill?

  • Dedicated protection for extraction turbines — the FREE FLOW valve (since 1929) closes quickly on a trip, isolating the heaters or process lines
  • Wide range of sizes and classes — 3–48 inches (80–1100 mm) or larger, ASME 150–2500, up to 1200 °F on FREE FLOW
  • Check valves with assisted closing — for cold reheat, boiler feed water and compressors, with air cylinder or oil dashpot
  • Main steam valves for nuclear power plants — MSIV to ASME Section III, with a one-piece forged stem
  • Y-type valves with an optional thermal compensation device — reduces stem stress during internal heating

Which Atwood & Morrill codes and series are requested most often?

CodeDescription
FREE FLOWReverse-flow valve for extraction turbines

Where is Atwood & Morrill equipment used?

  • Thermal and cogeneration plants — extraction turbines, protection against reverse flow
  • Nuclear power plants — main steam isolation valves
  • Compressors and blowers — check valves with assisted closing
  • Petrochemicals — Y-type and three-way valves for process
  • High-power boilers — feed water check valves

How do we supply Atwood & Morrill in Romania?

We can quote Atwood & Morrill valves from the FREE FLOW families, check valves, Y-type, three-way and parallel slide valves. We supply to order; for large valves or valves with a custom cylinder, the lead time may be longer, depending on the specification. For a correct quotation, send the valve type, the diameter, the ASME class, the working temperature and pressure, the body material, the type of connection, whether an existing part is being replaced (with the face-to-face length) and the air cylinder data. We give the exact lead time in the quotation.

Compatibility with an old valve is established from the face-to-face length and the cylinder interface, and nuclear qualifications are handled separately, based on the project documents.

Frequently asked questions about Atwood & Morrill

What products does Atwood & Morrill make?

Atwood & Morrill is a brand born in Salem (Massachusetts) in 1900. It makes valves for steam and high-pressure water: FREE FLOW for extraction turbines, check valves, Y-type, three-way and parallel slide valves, and MSIV valves for nuclear.

How do I size a FREE FLOW valve?

Start from the line diameter (3–48 inches and above), the ASME class (150–2500), the working temperature (up to 1200 °F) and the body material; the air cylinder is chosen by the mounting position. Send the extraction line diagram and the turbine data, and we check the configuration.

Can you supply Atwood & Morrill products in Romania, and how long does it take?

Yes, Atwood & Morrill products are supplied to order. A standard valve can be supplied to order, usually in 1–4 weeks, but large valves, or those with special cylinders or materials (for example F91), have a longer lead time, confirmed in the quotation.

Can I replace an old check valve with a current model?

This can be discussed only on the basis of the face-to-face length, the class, the diameter and the cylinder interface. Equivalences are not established by name alone; send the nameplate and, if there is one, the installation drawing, and we check which model takes over the function.

What details should I specify for a quotation on a Y-type or three-way valve?

The diameter and class, the fluid (steam or water), the pressure and temperature, the form of the connections (weld or flange), the material, the configuration wanted (stop, check or stop-check on the Y-type) and the type of actuation. For the three-way valve, add the two routes wanted.

How do I request a Atwood & Morrill quotation?

Send the Atwood & Morrill code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 23 November 2026 · Sources: Trillium Flow Technologies, Flowserve (manufacturer documentation)