Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Beckwith Electric supplier in Romania

Generator relays, tap controllers and bus transfer systems

Request a quote

Who is Beckwith Electric and what does it make?

Beckwith Electric is an American manufacturer of protective relays and controllers for power plants and distribution networks. It has evolved in generator protection, from static relays to multifunction digital systems with oscillography, programmable logic and self-diagnosis. The programme includes generator relays, controllers for on-load tap-changing transformers, voltage regulators, capacitor banks and motor bus transfer systems.

The M-3425A relay integrates in a single unit the major protection functions of a generator, regardless of prime mover, type of grounding or connection: from out-of-step (78) and split-phase differential (50DT) to inadvertent energisation (50/27) and inter-turn fault (59X). Options add 100 % stator protection by low-frequency injection (64S) and field circuit protection (64F/B). M-4272 moves the supply of motor buses to the standby source automatically or manually, choosing automatically between fast, in-phase and residual-voltage transfer.

This category of equipment is used in power plants, in substations with on-load tap-changing transformers and in industrial processes where loss of supply is not acceptable. A correct quotation starts from the type and rating of the generator, the grounding scheme and the existing relay you are replacing. The IPScom software simplifies settings and logic programming, and the Base and Comprehensive packages allow the level of protection needed to be chosen.

What do we supply from the Beckwith Electric range?

ProductDescription
M-3425A — complete generator relayDigital relay with comprehensive generator protections, Base and Comprehensive packages, options for Ethernet, field protection (64F/B), 100 % stator protection (64S) and extended inputs/outputs (15 output contacts and 8 additional inputs).
M-7651A D-PAC — distribution protection and controlUnit for feeders, switchgear, interconnections and small generators. It can work as a field unit and detects the electric arc; the boards have standard conformal coating.
M-2001D and M-6200A — tap and regulator controllersM-2001D is a universal tap-changer control, with adapter panels. M-6200A is a digital control for step voltage regulators, with automatic determination of forward or reverse mode.
M-4272 and M-6280A / M-6283AM-4272 provides motor bus transfer in power plants and industrial installations. M-6280A and M-6283A are digital controllers for capacitor banks, single-phase and three-phase.

Why Beckwith Electric?

  • M-3425A with Base and Comprehensive protection packages — functions from 21 and 78 to 64S, adaptable to generators
  • M-2001 adapter panels for tap-changer control — sized to replace the original control, with the same mountings and cables
  • M-4272 for motor bus transfer — selects automatically between fast, in-phase and residual-voltage transfer
  • Modbus, DNP3 and IEC 61850 communications on the tap controllers, with optional Ethernet and a fibre option
  • IPScom software for settings and programmable logic, common to the range of generator relays

Which Beckwith Electric codes and series are requested most often?

CodeDescription
M-3425AComplete relay for generator protection
M-7651AD-PAC, distribution protection and control
M-7679R-PAC, controller from the distribution line
M-2001DDigital control for the tap-changer
M-6200ADigital control for step voltage regulator
M-6280ADigital control for capacitor banks
M-6283AThree-phase control for capacitor banks
M-4272Digital motor bus transfer system
M-3919AGraphic display unit for M-4272
M-5072Retrofit kit for replacing certain analogue transfer systems

Where is Beckwith Electric equipment used?

  • Power plants — protection of generators with any type of prime mover
  • Substations — control of tap-changers and voltage regulators
  • Distribution — protection, automation and control of feeders and interconnections
  • Industrial installations — automatic motor bus transfer on loss of supply
  • Reactive power compensation — capacitor bank controllers

How do we supply Beckwith Electric in Romania?

We can quote Beckwith Electric generator relays, controllers and retrofit kits, depending on the data of your installation. Supplied to order, usually in 1–4 weeks; equipment configured with options may need a longer lead time, confirmed in the quotation. For a correct quotation send us the existing model (for example M-3425A or M-2001D), the order code from the nameplate, the generator rating, the functions required, the communication protocols and, for a retrofit, the make and model of the original control.

The compatibility of an adapter panel with the original control of a transformer or regulator is established from its make, model and wiring diagram.

Frequently asked questions about Beckwith Electric

What does Beckwith Electric make?

Beckwith Electric makes protective relays for generators, controllers for tap-changers and voltage regulators, capacitor bank controllers, distribution protection and control units and motor bus transfer systems.

What functions does the M-3425A relay include?

M-3425A includes major generator protections, among them out-of-step (78), split-phase differential (50DT), inadvertent energisation (50/27) and inter-turn fault (59X), plus 64S and 64F/B as options. Tell us the generator rating and the grounding scheme so that we can check the configuration.

Do you supply Beckwith Electric equipment in Romania, and in what time?

Yes. Beckwith Electric relays and controllers are supplied to order, usually in 1–4 weeks for standard items. Configured equipment may need longer; the exact lead time is confirmed in the quotation.

Can I replace an old tap-changer control with the M-2001D?

It can be checked: the M-2001D uses adapter panels sized to the original control, with the same mountings. You need to send us the make, model and series of the existing control and the wiring diagram. Compatibility is confirmed from these data.

What data do you need for a quotation on an M-4272 transfer system?

State the number of buses and sources (normal and standby), the bus voltage, the type of breakers, the transfer mode wanted (fast, in-phase or residual-voltage) and, if you are replacing an existing analogue system, its make.

How do I request a Beckwith Electric quotation?

Send the Beckwith Electric code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 22 November 2026 · Sources: Hubbell (manufacturer documentation)