Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Camlin Energy supplier in Romania

TOTUS online monitors: DGA, hydrogen, bushings and tap changer

Headquarters: Lisburn, United Kingdom (Northern Ireland)

Request a quote

Who is Camlin Energy and what does it make?

Camlin Energy is based in Lisburn, Northern Ireland, and works in the monitoring of transformers and electrical networks. For a maintenance engineer in a substation, the TOTUS suite is of particular interest: devices mounted on the transformer that continuously measure the gases dissolved in the oil and the condition of the insulation, instead of samples taken at long intervals.

TOTUS G1 measures the hydrogen and moisture in the oil and tracks the hot spot temperature, the loading limit and the dielectric strength. TOTUS G5 performs dissolved gas analysis (DGA) for hydrogen, methane, ethylene, acetylene, carbon monoxide and moisture, by photoacoustic spectroscopy, with a touch screen interface and remote access from a browser. TOTUS G9 extends the profile to nine gases plus moisture. Optionally, monitoring of partial discharges, of bushings (TOTUS BM), the through-fault current (TFC) and insulation ageing models can be added. TOTUS OLTC monitors the on-load tap changer: operations, mechanical movement, motor current, torque and temperature.

Such devices are of interest to operators of large transformers in 110–400 kV substations, and to heavy industry with process transformers. For a quotation, the transformer type, the oil type, the existence of a mounting port for sensors and the communication protocol wanted matter. A DGA monitor is also chosen by the space available on the tank, not just by the number of gases.

What do we supply from the Camlin Energy range?

ProductDescription
TOTUS G1 (hydrogen sensor)Real-time sensor for the hydrogen and moisture in the transformer oil, with thermal, moisture, load and insulation ageing models. It suits large fleets of transformers.
TOTUS G5 / G9 (DGA monitors)Online dissolved gas monitors: G5 measures five gases plus moisture by photoacoustic spectroscopy, and G9 measures up to nine gases plus moisture, with PD, BM and TFC options.
TOTUS BM (bushing monitor)Online monitoring of bushings and partial discharges, with a partial discharge triangle, automatic noise rejection and separate location of activity in the bushings and in the tank.
TOTUS OLTC (tap changer monitor)Continuous monitoring of the on-load tap changer: switching operations, mechanical movement, motor current, tap position, torque and temperature.

Why Camlin Energy?

  • Online DGA with photoacoustic spectroscopy — TOTUS G5 measures five gases plus moisture, and G9 reaches nine gases, without manual samples and without a laboratory
  • TOTUS G1, hydrogen and moisture sensor — a starting solution for large fleets of transformers, when a full DGA is not justified on every unit
  • TOTUS BM bushing monitoring — separates partial discharge activity in the bushings from that in the main tank, for locating the fault
  • TOTUS OLTC tap changer monitor — tracks torque, motor current and temperature, useful for transformers with intensive regulation duty
  • Analysis software included — thermal, moisture, load and insulation ageing models

Which Camlin Energy codes and series are requested most often?

CodeDescription
TOTUS G1Hydrogen and moisture in oil sensor
TOTUS G5DGA monitor with five gases plus moisture
TOTUS G9DGA monitor with up to nine gases plus moisture
TOTUS BMBushing and partial discharge monitor
TOTUS OLTCOn-load tap changer monitor
TOTUSPRODiagnostic software for TOTUS monitors
SapientData and analysis platform for the network

Where is Camlin Energy equipment used?

  • 110–400 kV substations — monitoring of power transformers
  • Power plants — step-up transformers with DGA monitoring
  • Heavy industry — process transformers with a high risk of shutdown
  • Network operators — fleets of transformers with hydrogen sensors
  • Predictive maintenance — analysis of DGA and tap changer data

How do we supply Camlin Energy in Romania?

For TOTUS monitors you can request a quotation by sending the transformer power and voltage, the oil type, the existence of a valve or a mounting port for the sensor, the type of tap changer (if you want OLTC), the communication protocol required and the options wanted (PD, BM, TFC). We supply to order; as the system is configured, the lead time may be longer depending on the specification and is confirmed in the quotation.

Compatibility with the transformer ports or with the existing SCADA system is established on the basis of the transformer datasheet; installation and commissioning are outside our offer.

Frequently asked questions about Camlin Energy

What does Camlin Energy make for transformers?

The TOTUS online monitoring suite: G1 (hydrogen and moisture), G5 and G9 (DGA with five and nine gases respectively), BM (bushings and partial discharges) and OLTC (tap changer). Analysis software is added.

How do I choose between TOTUS G1, G5 and G9?

G1 measures hydrogen and moisture and suits large fleets. G5 offers a DGA profile with five gases plus moisture, and G9 with up to nine gases. The PD, BM and TFC options are added to G5 and G9. Send the transformer power and the risk level.

Do you supply Camlin monitors in Romania and how fast?

TOTUS monitors are supplied to order. As they are configured for each transformer, the lead time to order usually exceeds 1–4 weeks; the firm date is set after the configuration is checked.

Can I fit a TOTUS monitor on an existing transformer?

It depends on the ports available on the tank, the oil type and the communication to SCADA. For the check we need the transformer datasheet, a photo of the valves or ports and the protocol wanted; compatibility is confirmed from these data.

What details do I need to send for a TOTUS OLTC quotation?

The type and manufacturer of the tap changer, the transformer voltage, whether there is a motor with current and torque measurement, the number of operations per year and the communication wanted. With these data we check whether the OLTC monitor suits the existing tap changer.

How do I request a Camlin Energy quotation?

Send the Camlin Energy code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 23 November 2026 · Sources: Camlin Group, Camlin Energy (manufacturer documentation)