PRO relays for buses, lines, feeders, transformers and TESLA recorders

Founded in 1993 · Headquarters: Winnipeg, Canada

Request a quote

Who is ERLPhase Power Technologies and what does it make?

ERLPhase Power Technologies is based in Winnipeg, Canada, and in 1993 its development team created a transformer protection relay. The current range includes multifunction numerical relays from the PRO family and disturbance recorders from the TESLA series.

The PRO family covers buses, feeders, lines and transformers: B-PRO for buses (up to 6 bays per relay, up to 24 in the multi-bus scheme), F-PRO for feeders (116, 216, 235, 297, 298 and 4500), L-PRO for transmission lines with five distance zones and T-PRO for transformers with several windings. The 4000 models are mounted in a 19 inch rack, and the 4500 in an E12 case, with 1 A and 5 A current inputs and, optionally, redundant PRP communication. The TESLA 4000 recorder simultaneously creates fault, swing and trend records, with over 1,000 definable triggers and a PMU function.

Such relays are used in high- and medium-voltage substations and in power plants, including refurbishments. For a quotation we need the ANSI functions required, the number of bays, the rated voltages and currents, plus the communication protocols. The relays include metering, event reporting with 1 ms resolution, DFR-quality oscillography and Windows software for configuration and disturbance analysis.

What do we supply from the ERLPhase Power Technologies range?

ProductDescription
B-PRO 4000 — bus protectionLow-impedance differential relay for any bus configuration, with security against current transformer saturation, breaker failure protection and overcurrent. Multi-bus version for large schemes.
F-PRO — feeder protectionMultifunction numerical relays for transmission, distribution and industry: F-PRO 116 (overcurrent), F-PRO 216 and 235, F-PRO 297 and 298 and F-PRO 4500, with event reporting at 1 ms resolution.
L-PRO 4000 and 4500 — line protectionMicroprocessor distance protection for medium- and extra-high-voltage lines, with directional protection, control for several breakers and backup for generators, transformers and reactors.
T-PRO and TESLA 4000T-PRO 2000, 4000 and 4500 protect transformers with several windings and shunt reactors; the TESLA 4000 is a disturbance recorder with PMU, CDR function and IEC 61850.

Why ERLPhase Power Technologies?

  • Multifunction numerical relays for buses, feeders, lines and transformers: the same platform and the same configuration software
  • B-PRO 4000 for buses: up to 6 bays per relay and up to 24 bays in the multi-bus scheme, with dynamic zone selection
  • L-PRO for medium- to extra-high-voltage lines: five distance zones and application in schemes with several breakers
  • Model 4500 in an E12 case with 1 A and 5 A current inputs: with optional PRP for redundant communication
  • TESLA 4000 recorder with PMU and IEC 61850 protocol: three time domains and over 1,000 definable triggers

Which ERLPhase Power Technologies codes and series are requested most often?

CodeDescription
B-PRO 4000Bus protection relay, up to 6 bays
B-PRO 4000 multi-busBus protection scheme, up to 24 bays
F-PRO 116Feeder overcurrent relay
F-PRO 216Non-directional overcurrent relay
F-PRO 235Feeder protection and management relay
F-PRO 297Feeder protection and management relay
F-PRO 298Feeder protection and management relay
F-PRO 4500Feeder protection and management relay
L-PRO 4000Distance protection for lines, 19 inch rack
L-PRO 4500Distance protection for lines, E12 case
T-PRO 2000Transformer protection
T-PRO 4000Transformer protection, 19 inch rack
T-PRO 4500Transformer protection, E12 case
TESLA 4000Disturbance recorder with PMU and IEC 61850
TESLA LITERecorder from the TESLA range

Where is ERLPhase Power Technologies equipment used?

  • Substations: protection of buses, lines, feeders and transformers
  • Power plants: backup protection of generators and disturbance recording
  • Transmission networks: monitoring with fault recorders and PMU
  • Heavy industry: feeder and transformer protection in their own installations
  • Refurbishments: replacing electromechanical and static relays

How do we supply ERLPhase Power Technologies in Romania?

We can quote ERLPhase relays from the PRO family and TESLA recorders, plus input and output modules, based on your protection scheme. Supplied to order, usually in 1–4 weeks; configurations by order code may need a longer lead time, confirmed in the quotation. For a correct quotation send us the relay type (for example L-PRO 4500), the ANSI functions required, the number of bays or current inputs, the rated voltages and currents, the protocols (IEC 61850, DNP3) and the auxiliary supply voltage.

The exact hardware version (4000 or 4500) for a replaced relay is established from the nameplate data and the mounting diagram.

Frequently asked questions about ERLPhase Power Technologies

What does ERLPhase Power Technologies make?

ERLPhase, from Winnipeg (Canada), makes multifunction numerical relays from the PRO family (buses, feeders, lines, transformers) and TESLA disturbance recorders with a PMU function. The company's roots go back to 1993.

What is the difference between the 4000 and 4500 models?

The 4000 model is a 3U or 4U 19 inch rack, while the 4500 is in an E12 case, with 1 A and 5 A current inputs and, optionally, redundant PRP communication. The user software is common. Tell us how the relay is mounted in the panel.

Do you supply ERLPhase relays in Romania, and how quickly?

Yes, to order. For individual items the lead time is usually 1–4 weeks, and relays configured by code may need more, confirmed in the quotation.

Can I replace an existing distance relay with an L-PRO?

It is analysed on the basis of the functions used, the line voltage, the type of teleprotection scheme, the number of breakers and the panel dimensions. We confirm equivalence with other makes on the basis of these data and after a check.

What should I send for a quotation for B-PRO bus protection?

State the number of bays and differential zones, the bus configuration, the current transformer ratios, the additional functions (breaker failure, overcurrent) and the communication protocol. For upgrades, add the single-line diagram.

How do I request a ERLPhase Power Technologies quotation?

Send the ERLPhase Power Technologies code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 22 November 2026 · Sources: ERLPhase Power Technologies Ltd. (manufacturer documentation)