IPEC supplier in Romania
For IPEC we quote ASM and ASM-Portable permanent partial discharge monitors, PD Detector Pro, PrecisePD and PD-SG1 portable testers and VDS, CC-TEV, AA and HFCT sensors; for a quotation we need the type of switchgear, the voltage and the number of channels.
Headquarters: Manchester, United Kingdom
Who is IPEC and what does it make?
IPEC is a British manufacturer headquartered in Manchester, specialising in instruments for the detection and monitoring of partial discharges (PD) on medium and high voltage equipment. A partial discharge is an electrical discharge that does not completely bridge two electrodes; it appears in degraded insulation and usually precedes a more serious fault. Measuring it early, with the equipment in operation, therefore helps in planning repairs.
The programme has three groups. The ASM permanent monitors are mounted in a 19-inch cabinet and can be configured for any number of sensor channels, up to 128 on medium voltage switchgear; they warn locally or by e-mail when the discharge exceeds the set threshold and send the data to a central database. ASM-Portable is the portable version, with up to 32 channels. The portable testers are used for periodic inspections: PD Detector Pro has a colour touchscreen and automatically distinguishes discharges from noise, PrecisePD is a testing and location system for cables and switchgear in high-noise environments, and PD-SG1 uses two transducers to detect transient earth voltages (TEV) and acoustic discharges. The sensors can also be used separately: VDS for the switchgear ports, capacitive CC-TEV for the metal enclosure, ultrasonic AA for terminations and HFCT for cables, fitted without disconnecting the earth connection.
Such instruments are relevant for transformer and distribution substations, for medium voltage cells, for underground cables and for industrial installations with large motors and generators.
What do we supply from the IPEC range?
| Product | Description |
|---|---|
| ASM — permanent partial discharge monitor | Monitor for cables, switchgear and other high voltage assets, in a 19-inch cabinet, with a configurable number of channels and a local or e-mail alarm. The data is downloaded automatically to a central database. On medium voltage switchgear, an ASM accepts up to 128 channels. |
| ASM-Portable — portable monitor | Portable version of the monitor, with up to 32 sensor channels, for cables, switchgear and other high voltage assets. The alarm is configurable locally or by e-mail, and the data (discharge peak, number of discharges, load, asset criticality) is plotted over time. |
| PD Detector Pro, PrecisePD and PD-SG1 — portable testers | PD Detector Pro detects TEV, acoustic discharges, high-frequency signals from cables and UHF signals from GIS. PrecisePD locates discharges on cables and switchgear, with processing for noisy environments. PD-SG1 uses two transducers for TEV and acoustic signals. |
| VDS, CC-TEV, AA and HFCT sensors | VDS connects to the switchgear ports, CC-TEV picks up TEV on the enclosure, ultrasonic AA detects activity below 10 pC on terminations, and HFCT, with a split ferrite core, is fitted on the earth connection of cables without disconnection. |
Why IPEC?
- ASM permanent monitors with up to 128 channels on medium voltage switchgear — partial discharge data recorded and analysed continuously
- Local or e-mail alarms, with a user-set threshold — equipment condition is followed remotely
- PD Detector Pro, PrecisePD and PD-SG1 portable testing — periodic inspections, with automatic differentiation between discharges and noise
- VDS, CC-TEV, ultrasonic AA and HFCT sensors — fitted on existing equipment, without invasive intervention
- Detection on air-insulated (AIS) and gas-insulated (GIS) cells, on cables and on medium and high voltage switchgear
Which IPEC codes and series are requested most often?
| Code | Description |
|---|---|
| ASM | Permanent partial discharge monitor, configurable number of channels |
| ASM-Portable | Portable partial discharge monitor, up to 32 channels |
| PD Detector Pro | Portable partial discharge tester, touchscreen |
| PD Detector | Portable tester for TEV, acoustic signals, high frequency and UHF |
| PrecisePD | Testing and location system for cables and switchgear |
| PD-SG1 | Detector with two transducers for switchgear |
| VDS | Compact sensor for switchgear ports |
| CC-TEV | Capacitive coupler for TEV detection |
| AA | Ultrasonic acoustic probe for terminations |
| HFCT | High-frequency current transformer, split core |
| DeCIFer | Signal processing for high-noise environments |
Where is IPEC equipment used?
- Transformer and distribution substations — monitoring of medium voltage switchgear
- Underground cable networks — detection and location of partial discharges
- Air-insulated and gas-insulated switchgear (AIS and GIS) — inspections with TEV, acoustic and UHF sensors
- Power transformers — partial discharge testing
- Large electrical machines — motors and generators monitored in operation
How do we supply IPEC in Romania?
We can quote IPEC partial discharge monitors, portable testers and sensors based on the data of your installation. The monitors, testers and sensors are supplied to order, usually in 1–4 weeks; for permanent systems configured by number of channels, depending on the specification, the lead time may be longer. For a quotation we need the type of equipment (medium voltage cells, cables, transformer, electrical machines), the rated voltage, whether the insulation is air or gas, the number of cells or measuring points, the type of sensors wanted and whether monitoring is permanent or by inspections. We confirm the exact lead time in the quotation.
The configuration of a permanent monitor is set by the number of channels, the type of switchgear and the voltage, and the interpretation of the measurements remains with the maintenance team.
Frequently asked questions about IPEC
What does IPEC make?
IPEC makes instruments in the United Kingdom for the detection and monitoring of partial discharges: ASM permanent monitors, portable monitors, portable testers such as PD Detector Pro, PrecisePD and PD-SG1, and sensors for switchgear, cables, transformers and electrical machines.
How do I choose between a permanent monitor and a portable tester?
The permanent monitor suits critical assets, where discharges must be followed continuously and with an alarm. The portable tester is used for periodic inspections on several cells or cables. Tell us how many measuring points you have and how critical the asset is, and we ask for a configuration recommendation.
Do you supply IPEC equipment in Romania, and how soon?
IPEC equipment is supplied to order, usually in 1–4 weeks. A permanent monitor is configured by number of channels, so depending on the specification the lead time may be longer. A sensor or a tester can ship in 24–72 h when the item is in stock, locally or at the supplier.
Can I add IPEC sensors to an existing monitoring system?
It can be checked, and compatibility with the IPEC system is confirmed after that check. Send us the make and model of the system, the type of inputs, the type of switchgear and the sensor you are looking for (TEV, UHF, ultrasonic or HFCT). We ask the factory to confirm compatibility with the existing inputs and, if the system has its own software, the format in which the data is exported.
What data do I need to send for a quotation on an ASM monitor?
Specify the number of cells or cables monitored, the total number of channels, the rated voltage, the insulation type (air or gas), the type of sensors, the way alarms are transmitted and the space available for the cabinet. With this data we prepare the quotation.
How do I request a IPEC quotation?
Send the IPEC code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: IPEC Ltd (manufacturer documentation)