Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

LS Cable & System supplier in Romania

EHV cables and 66–550 kV accessories: terminations, joints, link boxes

Founded in 1962 · Headquarters: Anyang, South Korea

Request a quote

Who is LS Cable & System and what does it make?

LS Cable & System is a South Korean cable manufacturer, headquartered in Anyang and active since 1962. For a substation or project engineer, the main interest is the high and extra-high voltage division: XLPE cables, oil-filled (OF) cables, submarine cables, as well as the accessories that connect them to the rest of the installation, from 66 to 550 kV. The company also has monitoring systems associated with cable routes, such as R-TAS®, which calculates the ampacity in real time from the temperature measured with optical fibre.

The Pro-Con series includes outdoor terminations (LSPA, with porcelain or polymer insulator), terminations for SF6 gas-insulated switchgear (LSPG) and for transformers (LSPO), in conventional or plug-in versions, for conductors of up to 2,500 mm². There are also one-piece prefabricated silicone rubber joints, accessories for oil-filled routes that make the transition to XLPE, link boxes with sheath voltage limiters and test terminations.

This type of equipment is used on underground 110 kV and 220 kV lines in cities, for connecting GIS substations and for projects replacing ageing oil-filled routes. A wrong item cannot be corrected on site, which is why exact data matters: the voltage, the conductor cross-section, the type of switchgear or transformer. Each termination is selected by voltage, conductor cross-section and the type of interface at the end of the line.

What do we supply from the LS Cable & System range?

ProductDescription
Pro-Con Outdoor Termination (LSPA)Outdoor termination with a prefabricated silicone rubber sleeve and a porcelain or polymer support insulator. It covers 72.5–550 kV, has a configurable creepage distance and does not require an oil tank.
Pro-Con GIS Termination (LSPG)Termination for SF6-insulated switchgear, with a stress-relief cone and an epoxy resin housing. It is made in a conventional or plug-in version, for XLPE cables of up to 2,500 mm².
Pro-Con Transformer Termination (LSPO)Termination for transformers, with oil insulation (EN 50299-1) or dry (EN 50299-2), with a plug-in version. The built-in insulating plate separates the cable sheath from the transformer tank.
Smart Pre-molded JointOne-piece joint with silicone rubber insulation, two semiconducting deflectors and a high-voltage electrode. The interface does not depend on mechanical devices, and installation is simplified.

Why LS Cable & System?

  • Accessories for 66–550 kV — terminations, joints, link boxes and test terminations, so the same supplier can stand behind a whole circuit
  • Outdoor terminations from 72.5–145 kV up to 500–550 kV — the creepage distance can be configured between 4,000 and 18,700 mm, depending on pollution at the site
  • GIS terminations conforming to IEC 60859 and IEC 62271-209 — conventional and plug-in versions, without an oil tank and without pressure monitoring
  • Transition from oil-filled cables to XLPE — accessories for maintenance of existing OF routes, including transition and branch joints
  • R-TAS® monitoring with optical fibre — conductor temperature and ampacity calculated along the route, useful on lines loaded close to the limit

Which LS Cable & System codes and series are requested most often?

CodeDescription
LSPA-01Outdoor termination, porcelain, 72.5–145 kV, creepage distance 4,000 mm
LSPA-07Outdoor termination, porcelain, 245–300 kV, 300–2,500 mm²
LSPA-11Outdoor termination, porcelain, 330–420 kV
LSPA-15Outdoor termination, porcelain, 500–550 kV
LSPA-02Outdoor termination, polymer, 72.5–145 kV
LSPG-01Conventional GIS termination, oil-filled, 72.5–100 kV
LSPG-05Conventional GIS termination, 245–300 kV
LSPG-09Dry GIS termination, 72.5–100 kV
LSPG-15Dry GIS termination, 362–550 kV
LSPO-01Oil-filled transformer termination, 72.5–100 kV
LSPO-09Dry transformer termination, 72.5–100 kV
LSPO-15Dry transformer termination, 362–550 kV
R-TAS®Monitoring system and real-time ampacity

Where is LS Cable & System equipment used?

  • Transmission grids — underground 110–400 kV lines in urban areas
  • Substations — connection to GIS and to power transformers
  • Power plants — power evacuation through high-voltage cables
  • Grid maintenance — replacing or extending oil-filled cable routes
  • Offshore connections — high-voltage submarine cables

How do we supply LS Cable & System in Romania?

From the LS Cable & System range we can quote high-voltage accessories (terminations, joints, link boxes) and, on request, information about cables. For an accurate quotation, tell us the service voltage, the cable cross-section and type, the kind of termination (outdoor, GIS or transformer) and, for GIS, the interface standard. Supplied to order; for equipment configured for a project the lead time may be longer depending on the specification, and the exact lead time is established in the quotation.

The compatibility of a termination with an existing GIS switchgear or transformer is established from the interface drawing and the cable data; the type and acceptance tests of a project are outside our offer.

Frequently asked questions about LS Cable & System

What does LS Cable & System make in the high voltage area?

XLPE and oil-filled (OF) extra-high voltage cables, submarine cables, superconducting cables, partial discharge monitoring systems and R-TAS®, plus the Pro-Con accessories for 66–550 kV: terminations, joints, link boxes and test terminations.

How do I choose between an LSPA, LSPG and LSPO termination?

It is chosen by where the cable ends up: LSPA for outdoor, with a porcelain or polymer insulator, LSPG for SF6-insulated switchgear and LSPO for entry into a transformer. Then the voltage, the cross-section (up to 2,500 mm²) and, for GIS and transformers, the interface standard matter.

Can you supply LS Cable accessories in Romania, and in what lead time?

Yes, to order. The order lead time is usually 1–4 weeks, and for items configured for a project it may be longer; the exact lead time is confirmed in the quotation.

Can I replace an existing oil-filled termination with a dry one?

It depends on the GIS or transformer interface. The LSPG/LSPO series has oil-filled and dry versions, and the dimensions can be adapted to existing systems. Send the interface drawing, the voltage and the cable cross-section, so that we check the fit before quoting.

What should I send for a quotation on a 110 kV cable circuit?

The maximum service voltage, the cable type and cross-section, the number of circuits and phases, the type of each termination (outdoor, GIS or transformer), the pollution conditions for the creepage distance and whether link boxes with sheath voltage limiters are needed.

How do I request a LS Cable & System quotation?

Send the LS Cable & System code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 22 November 2026 · Sources: LS Cable & System (manufacturer documentation)