NKT supplier in Romania
HV cable accessories 52–550 kV: joints, GIS terminations, LPOF–XLPE transition
Founded in 1891
Who is NKT and what does it make?
NKT is a Danish power cable company, founded in 1891. For the engineer working with underground high-voltage lines, the point of interest is the HV cable accessories division, from 52 to 550 kV, made at Alingsås, in Sweden. This is where the terminations, joints and transition accessories are produced that close an XLPE cable circuit or, in older networks, a low-pressure oil-filled cable (LPOF).
The range is divided by technology. One-piece prefabricated joints (KSME, 72.5–245 kV) or three-piece joints (SM, up to 550 kV) are installed without oil. GIS and transformer terminations come in a dry plug-in version (KSEV/KTEV, 72.5–550 kV) or an oil-filled one (SEV/TEV). Outdoor terminations range from the prefabricated dry TD model and the TSD model (123–170 kV, creepage distance of 32 mm/kV, pollution class IV) to the fluid-filled FEV model, for 72.5–550 kV. For older installations there are LPOF–XLPE transition joints (TJ, USM, MUDC) and straight joints for oil-filled cable.
These parts are installed in the modernisation of 110 kV underground routes in cities, in the connection of substations with GIS and in large power generation parks that export power by cable. The correct choice starts from the voltage, the conductor cross-section and the interface at the end of the line: GIS bay, transformer or outdoor busbar.
What do we supply from the NKT range?
| Product | Description |
|---|---|
| KSME / SME (one-piece prefabricated joint) | Straight joint for XLPE or EPR cables with Al or Cu conductor, in the 72.5–245 kV range. Supplied with heat-shrink outer protection (KSME) or with a housing (SME). |
| KSEV / KTEV (dry plug-in GIS and transformer termination) | Dry termination with plug-in connector for GIS bays and transformers, in the 72.5–550 kV range. The oil-filled version, SEV/TEV, covers 123–420 kV and is used when the existing interface requires an oil-filled termination. |
| FEV / KFEV / TSD (outdoor terminations) | Terminations for outdoor XLPE cable: FEV fluid-filled, 72.5–550 kV; KFEV dry plug-in, 123–300 kV; TSD dry, 123–170 kV. The insulators can be porcelain or composite. |
| TJ / USM / MUDC (LPOF–XLPE transition joints) | Joints for connecting a low-pressure oil-filled cable to an XLPE cable: TJ for 84–170 kV, USM for 170 kV single-core cable and MUDC for 36–52 kV three-core cable. |
Why NKT?
- Accessories for all levels from 52 to 550 kV — the range covers joints, terminations, screen separation kits and LPOF accessories
- KSEV/KTEV dry plug-in terminations for GIS and transformer — the termination insulation is dry, so there is no oil in the bay or in the transformer housing
- TSD termination for 123–170 kV — creepage distance of 32 mm/kV (pollution class IV according to IEC 60815-3), that is, a long distance along the insulator for heavily polluted locations
- LPOF–XLPE transition joints up to 170 kV — a solution for old oil-filled routes that are extended or replaced section by section
- Accessories for wind farms — 72.5 kV connectors and terminations for the inter-array cable
Which NKT codes and series are requested most often?
| Code | Description |
|---|---|
| KSME | One-piece prefabricated joint, heat-shrink protection, 72.5–245 kV |
| SME | One-piece prefabricated joint, with housing, 72.5–245 kV |
| KSM | Three-piece prefabricated joint, heat-shrink protection, 145–300 kV |
| SM | Three-piece prefabricated joint, with housing, 145–550 kV |
| SKKB | Screen separation kit |
| KSEV/KTEV | Dry plug-in GIS and transformer termination, 72.5–550 kV |
| SEV/TEV | Oil-filled GIS and transformer termination, 123–420 kV |
| TSD | Dry outdoor termination, 123–170 kV |
| KFEV | Dry plug-in outdoor termination, 123–300 kV |
| FEV | Fluid-filled outdoor termination, 72.5–550 kV |
| THV | Flexible dry outdoor termination, 72.5–245 kV |
| TJ | LPOF–XLPE transition joint, 84–170 kV |
| MVEO | Straight joint for single-core LPOF cable, 72–170 kV |
| EPO/EROW | Oil-filled outdoor termination for LPOF, 72–145 kV |
Where is NKT equipment used?
- Transmission networks — underground circuits of 110–400 kV in cities and at crossings
- Substations — terminations for GIS and power transformers
- Wind farms — 72.5 kV connectors and terminations for the inter-array cable
- Network maintenance — the changeover from LPOF oil-filled cables to XLPE
- Power industry — power export from power plants through underground cables
How do we supply NKT in Romania?
For NKT high-voltage products you can request a quotation by sending the rated voltage, the cross-section and type of cable (XLPE, EPR or LPOF), the type of termination required and the drawing of the GIS or transformer interface. They are supplied to order; the exact lead time depends on the configuration and is set after the quantities and the standards required are confirmed, sometimes beyond the usual 1–4 weeks. If you have an existing joint, a photo of the nameplate and of the dimensions helps us identify the suitable series.
Compatibility of an NKT joint with an accessory already installed by another manufacturer is established on the basis of the complete cable data; installation work and on-site tests remain the responsibility of the installation team.
Frequently asked questions about NKT
What does NKT make in the area of cable accessories?
NKT makes high-voltage cable accessories of 52–550 kV at Alingsås: prefabricated joints, terminations for GIS, transformer and outdoor use, LPOF–XLPE transition joints and accessories for low-pressure oil-filled cables, plus connectors for wind farm cables.
How do I choose between the dry plug-in termination and the oil-filled one?
The dry plug-in termination (KSEV/KTEV, 72.5–550 kV) contains no oil and suits GIS bays with a plug-in interface. The oil-filled one (SEV/TEV, 123–420 kV) is chosen when the existing interface requires it. Send the voltage, the cable cross-section and the interface drawing, so that we can check the version.
Can you supply NKT accessories in Romania, and within what lead time?
Yes, to order, usually in 1–4 weeks; for configurations with several types of joints or terminations on the same circuit the lead time can be longer and is confirmed in the quotation.
Can I replace an old joint for LPOF oil-filled cable?
For LPOF cables there are transition joints to XLPE (TJ, USM, MUDC) and straight joints, stop joints and oil-filled terminations. To establish what fits, we need the cable type (single-core or three-core), the voltage, the cross-section and how the joint is currently built.
What details should I give for an HV cable circuit quotation?
The maximum voltage, the type and cross-section of the cable, the diameter of the prepared insulation and of the sheath, the type of terminations (outdoor, GIS, transformer), the pollution level for the creepage distance and the number of circuits. With this data we can identify the series in the 52–550 kV range.
How do I request a NKT quotation?
Send the NKT code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.