RITZ Instrument Transformers supplier in Romania
HV instrument transformers 69–500 kV: IVO, ICO, CMO and CVO-type CCVT
Headquarters: Hamburg, Germany
Who is RITZ Instrument Transformers and what does it make?
RITZ Instrument Transformers GmbH is a German manufacturer of instrument transformers based in Hamburg, active for over 80 years, with nine locations in Europe, China and the USA and over 1,500 employees. It makes current and voltage transformers for low, medium and high voltage, plus busbars, cast resin parts and electronic sensors. In the high voltage segment, from 69 to 500 kV, the series with hermetically sealed oil-paper insulation, PCB-free oil and a stainless steel expansion cell are of interest.
The high voltage types are IVO (outdoor inductive voltage transformer, 72–245 kV), ICO (outdoor current transformer, 72–245 kV), CMO (combined current and voltage transformer, 72–245 kV) and CVO, a capacitive voltage transformer (CCVT) for high and extra high voltage substations. The CVO can take accessories for line carrier signal coupling (PLC), and the upper capacitor sections can be removed for transport. The CVO550EM version has a separate note on seismic safety according to IEEE 693.
Such devices are used in 110 and 220 kV substations, when replacing worn current or voltage transformers and in substations where revenue metering requires high accuracy classes. The nameplate data, that is the voltage, ratio, classes and overall dimensions, decide whether a new device fits in the place of the old one. The nameplate of the existing device is the starting point of the quotation.
What do we supply from the RITZ Instrument Transformers range?
| Product | Description |
|---|---|
| IVO (inductive voltage transformer) | Outdoor inductive voltage transformer, with oil-paper insulation, for 72–245 kV. It supplies voltage for energy meters, protection relays and other monitoring devices. |
| ICO (current transformer) | Outdoor current transformer with oil-paper insulation, for 72–245 kV, intended for energy metering, protections and current monitoring. |
| CMO (combined transformer) | Combined current and voltage transformer with oil-paper insulation, for 72–245 kV, in substations where both quantities are measured with a single device. |
| CVO (capacitive voltage transformer) | CCVT for high and extra high voltage substations. It can be equipped for PLC coupling, and the CVO550EM version has documentation for seismic safety according to IEEE 693. |
Why RITZ Instrument Transformers?
- A range from 69 to 500 kV — it includes 110 and 220 kV devices and, in the CVO version, extra high voltage substations
- Oil-paper in a sealed housing — PCB-free oil, a stainless steel expansion cell and O-ring seals fixed with a clamp
- The CMO type — current and voltage in the same device, useful when space in the substation is limited
- CVO with PLC accessories — it can couple line carrier signals for communications, without a separate device
- CVO550EM — documentation for seismic safety according to IEEE 693, for substations in seismic zones
Which RITZ Instrument Transformers codes and series are requested most often?
| Code | Description |
|---|---|
| IVO | Inductive voltage transformer, outdoor, 72–245 kV |
| ICO | Current transformer, outdoor, 72–245 kV |
| CMO | Combined current–voltage transformer, 72–245 kV |
| CVO | Capacitive voltage transformer (CCVT) |
| CVO550EM | CCVT with documentation for seismic safety IEEE 693 |
| GIS 12/24 | Indoor current transformer, support type, for medium voltage |
| GDS 10/36 | Indoor current transformer, pass-through type, medium voltage |
| GBERA 12/36 | Voltage sensor for medium voltage |
| EMWI 7xx | Electronic current transformer |
| EGIW X64 | Electronic voltage transformer |
| EGIW X85 | Electronic voltage transformer |
| EVBA X06 | Electronic voltage transformer |
Where is RITZ Instrument Transformers equipment used?
- Substations of 110–245 kV — current, voltage and combined transformers
- Extra high voltage substations — CVO-type CCVT
- Lines with PLC communication — CVO with coupling accessories
- Revenue metering — devices with accuracy classes for metering
- Heavy industry — in-plant high voltage substations
How do we supply RITZ Instrument Transformers in Romania?
For RITZ transformers you can request a quotation by sending the maximum voltage, the transformation ratio, the number of cores and the accuracy classes, the accuracy burdens, the thermal current and, for replacements, the nameplate and the overall dimensions of the existing device. The devices are supplied to order; the lead time is usually 1–4 weeks for simple configurations, and for devices of 145 kV and above it may be longer and is confirmed in the quotation.
Direct replacement of a device of another make with a RITZ device is confirmed from the complete nameplate and the dimensional drawing, and acceptance tests are outside our offer.
Frequently asked questions about RITZ Instrument Transformers
What does RITZ Instrument Transformers make?
From Hamburg, RITZ makes instrument transformers for low, medium and high voltage (69–500 kV), plus busbars, cast resin parts and electronic sensors or transformers. In high voltage: IVO, ICO, CMO and CVO, with oil-paper insulation.
How do I choose between IVO, ICO, CMO and CVO?
IVO is an inductive voltage transformer, ICO is a current transformer, CMO combines them, and CVO is a capacitive voltage transformer. The first three cover 72–245 kV; CVO goes to higher voltages. Send the voltage, the role of the device and the accuracy classes so that we check the type.
Can you supply RITZ devices in Romania, and within what lead time?
RITZ devices are supplied to order, usually in 1–4 weeks for simple versions. If the project requires high voltages or special conditions, such as seismic ones, the lead time increases.
Can I replace an old current transformer with a RITZ ICO?
It is checked from the nameplate of the old device: voltage, transformation ratio, cores, classes, burdens, thermal current and the dimensions of the base. Fit is confirmed once these data are available, because the new device must fit the existing foundation.
What details do I give for a quotation on a CVO-type CCVT?
The nominal voltage of the network, the transformation ratio, the accuracy classes and burdens, whether PLC coupling is needed, the seismic requirements (for example IEEE 693) and the pollution conditions. With this data we confirm the transformer configuration before the quotation.
How do I request a RITZ Instrument Transformers quotation?
Send the RITZ Instrument Transformers code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 23 November 2026 · Sources: RITZ Instrument Transformers GmbH (manufacturer documentation)