Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Tesient supplier in Romania

MP3000 and MP300 relay test sets, IEC 61850 instruments

Founded in 2000

Request a quote

Who is Tesient and what does it make?

Tesient Instrument is a Chinese company founded in 2000, which designs and makes protection relay test sets, equipment for IEC 61850 digital substations, voltage and current amplifiers for real-time simulation and programmable sources for fault indicators. Among its instruments are the M2000 relay tester, the MF3000 model, designed for relays with an optical interface in IEC 61850 substations, the MP3000F, an integrated digital-analogue tester, and the TMU-1000 for merging units. Production capacity exceeds 1,200 sets a year.

The MP3000 series is the core of the offer. The MP3000A and MP3000A1 are field test sets with six currents and four voltages, a modular structure with plug-in modules, full control from a PC, end-to-end testing with GPS or IRIG-B and a typical accuracy below 0.1% of reading plus 0.01% of range, and the A1 can also be operated locally. The MP3000F and MP3000F1 add testing of digital protections, with GOOSE and Sampled Values messages. The MP300 is a portable three-phase set, with 3×40 A and 4×300 V. The company also offers OEM solutions, with the option of supply under another brand and custom configuration.

This type of instrument is used in protection laboratories and by substation commissioning teams. The choice is made by the number of current and voltage channels and by whether the substation is conventional or digital.

What do we supply from the Tesient range?

ProductDescription
MP3000A / MP3000A1Three-phase relay test sets for multifunction field testing, with six currents and four voltages. The A1 version has local control. Voltage range 4×300 V / 100 VA, typical accuracy below 0.1% of reading plus 0.01% of range, PC control.
MP3000F / MP3000F1Integrated digital-analogue systems for testing conventional relays and IEC 61850 digital protections through GOOSE and Sampled Values, with the same six currents and four voltages as the A series, plus 12 low-level analogue outputs.
MP300Portable three-phase relay tester, with three 40 A (350 VA) current channels and four 300 V voltage channels, all-solid-state construction, for distribution substations, power plants and industrial installations.
TMU-1000Instrument for testing merging units in digital substations. It is complemented by programmable sources for fault indicators, of 1,000 A, and by real-time simulation amplifiers.

Why Tesient?

  • Six currents and four voltages on the MP3000A / F — one set covers distance, differential and directional protections without external extensions
  • Modular structure with plug-in modules — maintenance and extension are done locally
  • End-to-end testing with GPS or IRIG-B synchronisation — checking line protections between two substations
  • The F and F1 versions test conventional relays and IEC 61850 digital substations from the same instrument
  • Portable three-phase MP300, with 3×40 A and 4×300 V — the compact version for distribution substations and industrial installations

Which Tesient codes and series are requested most often?

CodeDescription
MP3000AThree-phase relay test set, 6 currents and 4 voltages
MP3000A1Relay test set with local control
MP3000FIntegrated digital-analogue IEC 61850 system
MP3000F1Digital-analogue system with local control
MP300Portable three-phase set, 3×40 A and 4×300 V
TMU-1000Tester for merging units
MF3000Tester for relays with an optical interface in IEC 61850 substations
M2000Protection relay tester, first generation

Where is Tesient equipment used?

  • Protection laboratories — checking electromechanical, static and digital relays
  • Substation commissioning — acceptance tests with a portable set
  • IEC 61850 digital substations — GOOSE, Sampled Values and merging units
  • Distribution networks — testing fault indicators with programmable sources
  • Real-time simulation — precision current and voltage amplifiers

How do we supply Tesient in Romania?

We can quote the MP3000A, MP3000F and MP300 test sets, the TMU-1000 instrument and the simulation amplifiers. They are supplied to order, usually in 1–4 weeks; OEM configurations or those with special modules may need more time, with the lead time confirmed in the quotation. For a correct quotation we need the number of current and voltage channels required, the maximum current, whether you work with IEC 61850 digital protections, the type of relays checked and the accessories wanted for GPS synchronisation.

The performance of a model is given by its rated values; for compatibility with a particular relay, its make and model are needed.

Frequently asked questions about Tesient

What does Tesient make?

Tesient Instrument, founded in 2000, makes protection relay test sets, instruments for IEC 61850 substations, amplifiers for real-time simulation and sources for fault indicators. The main series is MP3000, complemented by the MP300 for distribution substations.

What is the difference between the MP3000A and the MP3000F?

Both have six currents and four voltages. The MP3000A tests conventional relays with analogue outputs, while the MP3000F can also test IEC 61850 digital substations through GOOSE and Sampled Values. Tell us whether your installation has digital protections so that we identify the version.

Can you supply Tesient equipment in Romania, and within what lead time?

Yes, Tesient test sets are supplied to order. The lead time to order is usually 1–4 weeks; for OEM configurations or those with special modules it may be longer. We check the availability of the model requested, and the final lead time appears in the quotation.

Can the MP3000A do end-to-end tests on a line between two substations?

The MP3000A allows end-to-end testing with GPS or IRIG-B synchronisation. To confirm for your case we need the type of line protection, the distance between substations, access to the GPS signal and whether you need two test sets. We do the check before the quotation.

What details do you need for a quotation on a Tesient test set?

Send the number of current and voltage channels, the maximum currents, the types of protections to be tested, the substation protocol (analogue or IEC 61850) and the accessories for GPS or IRIG-B. If testing merging units is of interest, state their model.

How do I request a Tesient quotation?

Send the Tesient code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 23 November 2026 · Sources: Tesient Instrument Co. Ltd. (manufacturer documentation)