HV instrument transformers, air-core reactors and bushings, up to 800 kV

Headquarters: Berlin, Germany

Request a quote

Who is Trench Group and what does it make?

Trench Group is a manufacturer based in Berlin, with plants in Austria, Bulgaria, Canada, China, France, Germany and Italy, specialising in equipment for high-voltage substations: instrument transformers, air-core coils and bushings. For a substation engineer, what matters in particular is how the instrument transformers are built, because the manufacturer groups them by insulation medium: clean air (Clean Air), eco fluid (Eco Fluid), conventional fluid and conventional gas.

For current transformers, Clean Air reaches 420 kV and 6,000 A, Eco Fluid with paper–ester insulation 550 kV and 5,000 A, conventional fluid 550 kV and 5,000 A, and conventional gas 800 kV and 6,000 A. Capacitive voltage transformers with conventional fluid go up to 1,200 kV. From another family come the air-core coils (shunt reactors up to 550 kV and 250 Mvar, series reactors, line traps), the electronics for the ARCC® system for reducing the risk of forest fires and optical current transformers.

The range makes sense at 110–400 kV substations where an oil-filled measuring device has to be replaced, at underground substations or in areas with water protection, where eco fluid or clean air avoids mineral oil, and in reactive power compensation projects. Compatibility with the old device is established from the nameplate and the dimensions.

What do we supply from the Trench Group range?

ProductDescription
Current transformers: Clean Air, Eco Fluid, conventional fluid, conventional gasCurrent transformers on four insulation media: Clean Air up to 420 kV, Eco Fluid up to 550 kV, conventional fluid up to 550 kV, conventional gas up to 800 kV, with primary currents of 5,000–6,000 A.
Capacitive and inductive voltage transformersVoltage transformers: capacitive with conventional fluid up to 1,200 kV, plus inductive and combined, in Clean Air, Eco Fluid and conventional gas variants, including for GIS.
Air-core reactorsAir-core reactors: shunt up to 550 kV / 250 Mvar, series, for power quality, FACTS and HVDC, plus line traps. They contain no oil.
RIP, RIS and RIG bushingsTransformer, wall and generator bushings in RIP, RIS and RIG technology, plus bushings with eco or conventional fluid, for transformers and GIS.

Why Trench Group?

  • Four insulation media for the same function — clean air, eco fluid, conventional fluid and gas, so the choice is made by the substation environment
  • Eco Fluid CT with paper–ester up to 550 kV — can replace mineral-oil devices, with the same dimensions, in areas with water protection
  • Clean Air CT up to 420 kV — no mineral oil or SF6, and the construction withstands explosion to IEC 61869-1 Class II, verified by tests
  • Air-core shunt reactors up to 550 kV / 250 Mvar — oil-free and so with no fire risk, for reactive power compensation on transmission lines
  • CVT with conventional fluid up to 1,200 kV — for very high voltage networks

Which Trench Group codes and series are requested most often?

CodeDescription
ARCC®Forest fire risk reduction system

Where is Trench Group equipment used?

  • 110–400 kV substations — current and voltage instrument transformers
  • Underground substations and water protection areas — devices with eco fluid or clean air
  • Transmission networks — shunt reactors and line traps for compensation and communication
  • HVDC lines — air-core reactors and bushings for direct current
  • Power generation — bushings and instrument transformers in power plants

How do we supply Trench Group in Romania?

For Trench products you can request a quotation by sending the maximum voltage, the transformation ratio, the accuracy classes, the rated burden, the insulation medium wanted (clean air, eco fluid, conventional or gas) and the standard (IEC or IEEE). For replacements, the nameplate and the dimensional drawing of the old device are essential. They are supplied to order, usually in 1–4 weeks for simple configurations; for high-voltage devices the lead time can be longer and is stated in the quotation.

Equivalence with a device from another manufacturer and the delivery date are established from the complete nameplate; acceptance tests and commissioning remain outside the offer.

Frequently asked questions about Trench Group

What products does Trench Group make?

Trench makes high-voltage instrument transformers (current, inductive and capacitive voltage, combined) on four insulation media, air-core coils (shunt and series reactors, line traps), RIP, RIS and RIG bushings and optical current transformers. The head office is in Berlin.

How do I choose between clean air, eco fluid and gas insulation?

Clean air (CT up to 420 kV) avoids mineral oil and SF6, paper–ester eco fluid (up to 550 kV) replaces mineral oil at the same dimensions, and gas (up to 800 kV) applies at higher voltages. Send the voltage, the substation environment and the device to be replaced.

Do you supply Trench equipment in Romania and in what time?

Trench equipment is supplied to order. The lead time to order is usually 1–4 weeks for simple configurations, while devices of 245 kV and above, like reactors, usually need longer.

Can I replace a mineral-oil current transformer with an eco fluid one?

The Eco Fluid CT series can replace mineral-oil devices, at the same dimensions, up to 550 kV. For confirmation we need the nameplate of the old device, the transformation ratio, the accuracy classes and the dimensional drawing.

What data should I send for a quotation for an air-core reactor?

The network voltage, the reactive power in Mvar (for shunt) or the inductance and rated current (for series reactors), the frequency, the standard (IEC or ANSI/IEEE), the installation conditions and space constraints. On this basis we check the configuration before issuing the quotation.

How do I request a Trench Group quotation?

Send the Trench Group code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote