Arteche supplier in Romania
HV instrument transformers up to 800 kV and optical current sensors
Founded in 1946 · Headquarters: Mungia, Spain
Who is Arteche and what does it make?
Arteche is an industrial group from the Basque Country, based at Mungia (Bizkaia), founded in December 1946. It makes instrument transformers for high voltage, optical current sensors, auxiliary and trip relays, substation automation equipment and capacitor banks. For a substation or protection engineer, the current and voltage transformers for 72.5–800 kV are of particular interest, that is, the devices that feed the relays and meters in a substation.
The high-voltage range includes the CA series of current transformers, with oil–paper insulation and the core in the head (live tank), up to 800 kV, the dry-insulated CX series up to 72.5 kV, the UT series of inductive voltage transformers up to 550 kV and the KA series of combined transformers up to 245 kV. There are also DDB/DFK capacitive transformers and DDN/DFN coupling capacitors, both up to 800 kV. The digital side is represented by SDO-OCT, a passive and modular optical current transformer, and by SDO-MU, the IEC 61850 merging unit.
Such devices are installed in 110 kV, 220 kV and 400 kV substations, in refurbishments where an instrument transformer is replaced on the same foundation and in projects with IEC 61850 automation. For a correct quotation, the transformation ratio, the accuracy classes and the rated data of the device being replaced matter. The nameplate of the old device is the starting point of any quotation.
What do we supply from the Arteche range?
| Product | Description |
|---|---|
| CA / LB / CG (HV current transformers) | High-voltage current transformers. The CA series has oil–paper insulation and reaches 800 kV; the dry-insulated CX series goes up to 72.5 kV; LB and CG are other HV series. |
| UT / UG (inductive voltage transformers) | Inductive voltage transformers for high voltage. The UT series, with oil–paper insulation, covers up to 550 kV and is offered alongside the UG series. |
| DDB/DFK and DDN/DFN (capacitive and coupling capacitors) | DDB/DFK capacitive voltage transformers and DDN/DFN coupling capacitors, both up to 800 kV, with hermetically sealed oil–paper insulation. |
| SDO-OCT and SDO-MU (digital) | SDO-OCT is a passive, modular optical current transformer, usable at any voltage level. SDO-MU is the IEC 61850 merging unit that processes the optical signal. |
Why Arteche?
- CA current transformers up to 800 kV — live-tank design with oil–paper insulation, so the same manufacturer can cover 110, 220 and 400 kV
- UT inductive transformers up to 550 kV and DDB/DFK capacitive transformers up to 800 kV — for substations where one or the other voltage measuring technology is used
- KA combined transformer up to 245 kV — current and voltage in the same device, useful when substation space is limited
- SDO-OCT optical current transformer — passive, with no oil and no SF6, with the only active element in the IEC 61850 merging unit
- CX series with dry insulation, up to 72.5 kV — an oil-free alternative at lower voltages
Which Arteche codes and series are requested most often?
| Code | Description |
|---|---|
| CA | HV current transformer series, up to 800 kV |
| LB | HV current transformer series |
| CG | HV current transformer series |
| CX | Dry HV current transformers, up to 72.5 kV |
| UT | HV inductive voltage transformers, up to 550 kV |
| UG | HV inductive voltage transformer series |
| KA | HV combined transformers, up to 245 kV |
| DDB/DFK | Capacitive voltage transformers, up to 800 kV |
| DDN/DFN | Coupling capacitors, up to 800 kV |
| SDO-OCT | Passive optical current transformer |
| SDO-MU | IEC 61850 merging unit |
| SDO-FCT | Flexible current transformer |
Where is Arteche equipment used?
- 110–400 kV substations — measurement and protection
- Substations with IEC 61850 automation — optical transformers and merging units
- HVDC lines — optical current transformers for direct current
- Power generation — power evacuation from large generation parks
- Heavy industry — plant-owned high-voltage substations with measurement and protection
How do we supply Arteche in Romania?
For Arteche instrument transformers, you can send us the maximum equipment voltage, the transformation ratio, the number and accuracy classes of the secondary windings, the accuracy burden and the standard (IEC or IEEE). If you are replacing an existing device, a photo of the nameplate and the base dimensions help us identify the series. We bring them in to order, usually in 1–4 weeks for simple configurations; for devices of 245 kV and above the lead time may be longer and is confirmed in the quotation.
Equivalence with an instrument transformer from another manufacturer is established from the full nameplate and the outline drawing, and the project's acceptance tests are outside our offer.
Frequently asked questions about Arteche
What does Arteche make for high-voltage substations?
Current transformers (CA, LB, CG, CX), inductive voltage transformers (UT, UG), combined transformers (KA), capacitive transformers (DDB/DFK) and coupling capacitors (DDN/DFN), plus SDO-OCT optical current transformers and IEC 61850 merging units. The high-voltage range goes up to 800 kV.
How do I choose between an inductive and a capacitive voltage transformer?
The UT inductive series goes up to 550 kV, and the DDB/DFK capacitive series up to 800 kV. The choice depends on the network voltage, the role of the device in the substation and the type you are replacing. Send the voltage, the accuracy classes and a photo of the nameplate.
Can you supply Arteche transformers in Romania and within what lead time?
Yes, to order; usually 1–4 weeks for simple configurations, longer for devices of 245 kV and above. The exact lead time is confirmed in the quotation, after the rated data and accuracy class are checked.
Can I replace an old current transformer with an Arteche one?
It can be checked starting from the nameplate of the old device: transformation ratio, classes, burdens, maximum voltage, thermal and dynamic current, plus the base outline. Fit is confirmed once these data are seen, because the new device must fit on the existing foundation.
What data do I send for a quotation on instrument transformers?
The maximum network voltage, the frequency, the transformation ratio, the number of cores or windings, the accuracy class, the accuracy burden, the environmental conditions and the creepage distance required. For digital devices, also state the protocol (IEC 61850) and the number of channels.
How do I request a Arteche quotation?
Send the Arteche code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: Arteche, Wikipedia (manufacturer documentation)