b2 electronics supplier in Romania
VLF sources, PD/TD cable diagnostics and oil testers
Founded in 2001 · Headquarters: Klaus, Austria
Who is b2 electronics and what does it make?
b2 electronics is an Austrian company from Klaus, established in 2001, specialising in compact test and diagnostic equipment for medium- and high-voltage power cables and in transformer oil testers. Research, development and manufacturing take place in Austria. The basic idea is a portable low-frequency source that can replace bulky cable test sources in the field.
The HVA series includes VLF sources from 28 kV to 200 kV (peak), from the HVA28 and HVA34 to the HVA120 and HVA200, some with integrated loss-angle tangent diagnostics (HVA45 TD, HVA68 TD), and the HVA68 TD with arc pre-location. The PDTD series adds partial discharge and tan delta measurement in the same instrument, from the PD30 to the PDTD200-2. The smartCFL range, with the CTL12 model, helps with the pre-location and location of cable faults, and the BA75, BA80 and BA100 are oil testers of up to 100 kV.
The equipment is used by distribution and transmission operators with ageing medium-voltage cables, by contractors who commission underground lines and by transformer oil laboratories. The choice is made from the cable voltage, its capacitance and the need for diagnostics, not just a withstand test, and for oil from the test standard applied.
What do we supply from the b2 electronics range?
| Product | Description |
|---|---|
| HVA — VLF sources | Low-frequency sources for the voltage test of cables, from the 28 kV models up to the HVA200 (141 kV effective), with variants with tan delta diagnostics and arc pre-location. Software control, for measurements and reports. |
| PDTD — PD and TD diagnostics | Compact, portable and modular systems for measuring partial discharge and tan delta on cables, with test voltages of up to 141 kV effective and location of discharges along the cable. |
| smartCFL / CTL12 | A family of kits for locating cable faults: insulation and sheath testing, pre-location and exact location. The CTL12 weighs 12.8 kg and is the first model of the family, with guided workflows. |
| BA — oil testers | Automatic breakdown analysers for the laboratory or the field: BA75 (75 kV), BA80 (80 kV) and BA100 (100 kV), with test sequences compliant with the standards, an RFI/EMC shielded housing and battery power. |
Why b2 electronics?
- HVA VLF sources from 28 to 200 kV (peak) — from medium-voltage cables up to 132 kV networks in the same product family
- TD and PD diagnostics integrated in portable instruments (HVA TD, PDTD) — a single trip, without transporting the source, the divider and the detector separately
- The PDTD series measures partial discharge and tan delta simultaneously — the cable is not conditioned twice
- BA75, BA80 and BA100 oil testers with a switch-off time below 5 µs — repeatable results on mineral, silicone and ester oils
- Manufacturing, development and calibration in Austria — a single site is responsible for the product, from design to delivery
Which b2 electronics codes and series are requested most often?
| Code | Description |
|---|---|
| HVA28 | Compact VLF source from the HVA series |
| HVA34 | VLF source from the HVA series, 34 kV peak |
| HVA45 TD | VLF source with integrated tan delta |
| HVA68-2 | Dual-power VLF source, 68 kV peak |
| HVA90 | VLF source from the HVA series |
| HVA120 | VLF source from the HVA series |
| HVA200 | VLF source up to 200 kV peak (141 kV effective) |
| PDTD68 | PD and TD diagnostic system in a single housing |
| PDTD120-2 | PD and TD diagnostic system, -2 series |
| PDTD200-2 | PD and TD diagnostic system, -2 series |
| PD60-2 | Partial discharge detector, PD series |
| CTL12 | smartCFL kit for locating cable faults |
| BA75 | Oil tester, 75 kV effective, 22 kg |
| BA80 | Oil tester, 80 kV effective, 22 kg |
| BA100 | Oil tester, 100 kV effective, 32 kg |
Where is b2 electronics equipment used?
- Power distribution — VLF tests and diagnostics of medium-voltage cables
- Power transmission — tests on high-voltage cables up to 132 kV
- Underground network contractors — commissioning of new or repaired lines
- Fault location — mobile kits for call-outs
- Laboratories and substations — testing the dielectric strength of transformer oil
How do we supply b2 electronics in Romania?
We can quote the HVA series VLF sources, PDTD systems, smartCFL kits and BA oil testers. Supplied to order, usually in 1–4 weeks; configured systems can have a longer lead time, confirmed in the quotation. For an accurate quotation we need the rated voltage of the cables, their length and capacitance, whether you want only the voltage test or also diagnostics (TD, PD), the type of oil to be tested and whether the equipment is to be installed in a vehicle.
The configuration of a VLF source depends on the capacitance of the cable to be tested, because the maximum load differs widely between models.
Frequently asked questions about b2 electronics
What does b2 electronics make?
b2 electronics, established in 2001 in Klaus, Austria, makes VLF test sources, cable diagnostic systems (tan delta and partial discharge), fault location kits and transformer oil testers.
How do I choose an HVA series VLF source for a cable?
The starting point is the test voltage required by the standard and the capacitance of the cable: each model has a maximum load at 0.1 Hz and at a given voltage. The values are in the series table. Send us the length, cross-section and type of the cable so that we can narrow down the choice.
Can you supply b2 electronics equipment in Romania, and in what time?
Yes, b2 electronics products are supplied to order; the lead time is usually 1–4 weeks. Configured systems with diagnostics or accessories can have a longer lead time. The availability of a model is confirmed before the quotation.
Does a PDTD replace a separate tan delta and partial discharge set?
The PDTD series is designed to measure partial discharge and tan delta simultaneously, which avoids conditioning the cable twice. If you already have a system, tell us the make, the maximum voltage and the reporting requirements, and we check the compatible version, including the extension of an existing HVA source.
What do I need to send for a quotation on a BA oil tester?
Send the standard to which testing is done (IEC or ASTM), the type of oil (mineral, ester, silicone), the expected breakdown voltage and whether the instrument is used in the laboratory or in the field. For field use, also state whether battery power is needed.
How do I request a b2 electronics quotation?
Send the b2 electronics code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: b2 electronics GmbH (manufacturer documentation)