Who is Tanbos and what does it make?

Tanbos Electric Technology (Hangzhou) is a Chinese company founded in 2012, based in Hangzhou, specialising in instruments for locating faults in cables and analysing their condition: fault locators, cable identifiers, damped wave (DAC) test systems, VLF sources and acoustic cameras. The company has a 90,000 m² industrial park, more than 200 technicians and a training centre, and holds patents for its products. The fault of a buried cable cannot be seen from the surface, which is why locating it is done with dedicated instruments.

The range is split into three families. For fault location: portable systems T8 (low voltage cables), T20 (1–35 kV cables, with a 32 kV, 1,024 J surge generator) and T32, the TBS-1000 vehicle system, the LB4-60A digital bridge, the WL20 reflectometer, the WL50+ pre-locator, the LP30/2 and LP30-4+ surge generators, the SPC-20 arc stabilisation unit and the PP20 position detector. For testing and diagnosis: TV30 and TV60 (DAC with partial discharges measured according to IEC 60270) and 40 kV and 90 kV VLF sources. The third family comprises the HCI, FCI and ECI cable identifiers.

The instruments are used by medium voltage network operators, by underground network companies and by response teams with location vehicles. Selection starts from the cable voltage and the type of fault.

What do we supply from the Tanbos range?

ProductDescription
T20 / T32 / T8 — portable systemsPortable fault location systems: T8 for low voltage cables, T20 for medium voltage cables of 1–35 kV, with a 32 kV, 1,024 J surge generator, LV TDR, ICE and ARM methods and magneto-acoustic positioning, and T32. The parts can be used independently.
TBS-1000A light, smart system for installation in a vehicle, with DC test and surge pulse modes at 8, 16 and 32 kV, integrated TDR, ARM, ICE and DECAY, a fully insulated design and tablet control with Auto Go software.
TV30 / TV60 — DAC systemsTest and diagnostic sets with damped alternating voltage (DAC): TV60 has 60 kV peak, for cable systems up to 36 kV, integrated TDR and partial discharge measurement. TV30 is the version for medium voltage cables.
LB4-60A, WL20, WL50+, PP20, LP30Components for the location chain: a digital bridge with a burn-down source of 0–60 kV, WL20 and WL50+ reflectometers for pre-location, the PP20 detector for identifying the fault point and the LP15-8, LP30/2 and LP30-4+ surge generators.

Why Tanbos?

  • The T20 system with three independent parts — the WL20 reflectometer, the LP30/2 generator and the PP20 detector can be used separately when needed
  • TBS-1000 for installation in a vehicle — tablet control, TDR, ARM, ICE and DECAY integrated, with a smart mode and an expert mode
  • TV60 DAC with integrated TDR — testing and diagnosis of cables up to 36 kV in a single instrument, with partial discharge measurement according to IEC 60270
  • HCI, FCI and ECI cable identifiers — selecting the target cable is safer before cutting or an intervention
  • 40 kV and 90 kV VLF sources alongside the DAC systems — cable acceptance can be done both with damped wave tests and with VLF

Which Tanbos codes and series are requested most often?

CodeDescription
T8Portable location system, low voltage cables
T20Portable system, 1–35 kV cables, 32 kV / 1,024 J surge
T32Portable fault location system
TBS-1000Vehicle system, 8/16/32 kV
LB4-60ADigital bridge and burn-down source 0–60 kV
WL20TDR reflectometer
WL50+TDR pre-locator
PP20Fault position detector
SPC-20Multi-pulse arc stabilisation unit
LP30/2Surge generator 0–32 kV
LP30-4+Surge generator for location
TV30DAC system for medium voltage cables
TV6060 kV DAC system, cables up to 36 kV
HC-10Sheath fault location system
HCISmart cable identifier

Where is Tanbos equipment used?

  • Electricity distribution — locating faults on underground medium voltage cables
  • Network contractors — acceptance of new or repaired cables, through DAC and VLF tests
  • Rail transport and energy — power and signal cables
  • Industrial installations — identifying cables before interventions
  • Acoustic diagnosis — detecting electrical faults and gas leaks with an acoustic camera

How do we supply Tanbos in Romania?

We can quote the T8, T20, T32 and TBS-1000 fault location systems, the WL, LP and PP components, the TV30 and TV60 DAC systems and cable identifiers. They are supplied to order, usually in 1–4 weeks; for systems fitted in a vehicle or configured to a project the lead time may be longer, confirmed in the quotation. For a correct quotation we need the cable voltage, the type of faults encountered (short circuit, intermittent fault), the usual lengths, how the instrument is transported and whether diagnosis is also wanted, not just location.

Compatibility with a specific vehicle or power source is established once the concrete installation data is received.

Frequently asked questions about Tanbos

What product range does Tanbos have?

Tanbos, a company from Hangzhou founded in 2012, makes instruments for locating faults in cables, cable identifiers, DAC and VLF systems for testing and diagnosis, and acoustic cameras. The offer starts from portable instruments and reaches systems fitted in vehicles.

How do I choose between T20, T32 and TBS-1000?

The T20 is a portable system for medium voltage cables of 1–35 kV, with a 32 kV surge, while the TBS-1000 is fitted in a vehicle and offers test voltages of 8, 16 and 32 kV with tablet control. The choice depends on the cable voltage and the way of working; send us both.

Do you supply Tanbos equipment in Romania, and how quickly?

Yes, Tanbos systems are supplied to order. The lead time to order is usually 1–4 weeks, and vehicle systems or those with several components may have a longer lead time. We confirm it in the quotation, after availability is checked.

Does a TV60 DAC replace a VLF source for cable acceptance?

The TV60 is a 60 kV peak DAC set for cables up to 36 kV, with integrated TDR and partial discharge measurement. Equivalence with a specific VLF source depends on the test voltage principle, which differs. Tell us the applicable acceptance standard, and we check the suitable option.

What data do you need for a quotation on a fault location system?

Send the cable voltage, the insulation type (XLPE, paper), the usual lengths, the types of faults encountered and whether the instrument is fitted in a vehicle or carried by hand. Also state whether you need a cable identifier or DAC diagnosis.

How do I request a Tanbos quotation?

Send the Tanbos code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 22 November 2026 · Sources: Tanbos Electric Technology (Hangzhou) Co., Ltd. (manufacturer documentation)