SEG Electronics supplier in Romania
HighPROTEC protection relays, self-powered WIC1 and Professional Line for MV
Founded in 1969 · Headquarters: Kempen, Germany
Who is SEG Electronics and what does it make?
SEG Electronics GmbH was founded in 1969 in Krefeld and has worked in Kempen since 1974. It develops and manufactures medium-voltage protection relays for power generation and distribution. The company's history includes the self-powered WI1-3 relay, introduced in 1988 for ring main units (RMU), and the multifunctional numerical HighTECH line, introduced in 1990.
The current range has several lines. HighPROTEC is the numerical line with a dual-core processor: MRA4 for feeders, MRI4 for overcurrent, MRU4 for voltage, MRM4 for motors, MCDTV4 for transformers, MCDGV4 for generators and MCA4 for grid connection of distributed generation. WIC1 g2 is the self-powered relay, which takes its energy from the current signals and starts in less than one cycle. Professional Line offers simple protections on a DIN rail, adjustable by potentiometers and DIP switches, without a computer, and HighTECH Line is the modular line with modules that can be replaced in operation.
Such relays are used in medium-voltage switchboards, for motor and generator protection and for grid interconnection of photovoltaic plants or other distributed sources. A correct quotation starts from the ANSI functions required, the rated voltages and currents and the communication protocols. The relays are designed for ANSI and IEC standards, the applicable grid codes, such as G99 or IEEE 1547, are checked per project, and the Smart view parametrisation program is available for the HighPROTEC line. The same program is used to configure HighTECH, Professional Line and WIC1 g2 relays, and the Smart view interface also allows disturbance evaluation.
What do we supply from the SEG Electronics range?
| Product | Description |
|---|---|
| HighPROTEC MRA4, MRI4, MRU4, MRM4 | Numerical relays with a dual-core processor: MRA4 protects incoming and outgoing feeders, MRI4 overcurrent, short-circuit and earth fault, MRU4 overvoltage and undervoltage, MRM4 low- and medium-voltage motors. |
| HighPROTEC MCDTV4, MCDGV4 and MCA4 | MCDTV4 is a complete solution for high-, medium- and low-voltage transformers; MCDGV4 provides differential protection of medium and large power generators; MCA4 connects distributed generation systems, such as wind, photovoltaic or biogas, to the grid. |
| WIC1 g2 — self-powered relay | Protection relay that takes its energy from the current transformers, with a dual-supply version, parametrisation through Smart view, DiggiMEC or DIP/HEX switches and Modbus RTU or TCP communication on WIC1-4. |
| Professional Line and HighTECH Line | Professional Line is the DIN-rail line, for common protections at low and medium voltage. HighTECH Line is the modular line for overcurrent, machine protection and differential protection. |
Why SEG Electronics?
- Self-powered WIC1 g2 — needs no auxiliary voltage, starts in less than one cycle and fits the same cut-out as its predecessor
- HighPROTEC — numerical protection functions and Smart view software for parametrisation
- Modbus, Profibus, DNP3.0, IEC 61850, IEC 60870-5-103 and -104 protocols on the HighPROTEC line
- Professional Line — setting without a computer, from front-panel buttons, with a sealable cover and one-button self-test
- HighTECH Line — plug-in modules with automatic short-circuiting of the current inputs, replaceable in operation
Which SEG Electronics codes and series are requested most often?
| Code | Description |
|---|---|
| MRA4 | HighPROTEC, feeder protection |
| MRI4 | HighPROTEC, overcurrent protection |
| MRU4 | HighPROTEC, voltage protection |
| MRM4 | HighPROTEC, motor protection |
| MCDTV4 | HighPROTEC, transformer differential protection |
| MCDLV4 | HighPROTEC, relays of the MCD family |
| MCDGV4 | HighPROTEC, generator differential protection |
| MCA4 | HighPROTEC, grid connection of distributed generation |
| WIC1 | Self-powered protection relay |
| WIC1-4 | WIC1 version with Modbus RTU or TCP |
| XRI | Professional Line, relay of the XR family |
| XD1-G | Professional Line, relay of the XD family |
| XRS1 | Interface adapter for Professional Line |
Where is SEG Electronics equipment used?
- Power plants — generator protection with differential relays
- Medium-voltage switchboards and substations — protection of feeders, transformers and motors
- Renewable energy — grid connection and interconnection protection
- Ring main units (RMU) — WIC1 self-powered relays
- Industry — protection of low- and medium-voltage motors
How do we supply SEG Electronics in Romania?
We can quote SEG relays from the HighPROTEC, WIC1, Professional and HighTECH lines, based on the data of your installation. We supply to order, usually in 1–4 weeks; relays configured by order code may need a longer lead time, confirmed in the quotation. For a correct quotation, send us the relay type (for example MRA4, MRM4 or WIC1), the order code from the nameplate, the ANSI functions required, the rated current and voltage, the auxiliary voltage and the communication protocol, if required.
The exact order code of a relay is established after the configuration has been checked against the functions required and the rated data of the installation.
Frequently asked questions about SEG Electronics
What products does SEG Electronics make?
SEG Electronics GmbH, founded in 1969 and active at Kempen (Germany), makes medium-voltage protection relays: numerical HighPROTEC, self-powered WIC1, Professional Line on a DIN rail and modular HighTECH Line, for feeders, motors, transformers and generators.
When do I choose a self-powered WIC1 relay?
WIC1 suits cases where there is no auxiliary voltage, for example in ring main units (RMU): it takes its energy from the current signals and starts in less than one cycle. For communication there are dual-supply versions. Tell us the cell type and the rated currents.
Do you supply SEG relays in Romania, and how long does it take?
Yes, items are supplied to order. Relays with a special configuration may take longer, and the exact lead time is confirmed in the quotation.
Can I replace an old SEG relay with a HighPROTEC series?
This can be checked from the old type on the nameplate, the ANSI functions used, the rated data and the mounting dimensions. Equivalence is confirmed from these data and from a check of the wiring diagram.
What do I need to send for a quotation for an MRM4 motor relay?
State the motor power and voltage, the rated current, the type of starting, the need for temperature probe inputs, the auxiliary voltage and the communication protocol, if required.
How do I request a SEG Electronics quotation?
Send the SEG Electronics code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: SEG Electronics GmbH (manufacturer documentation)