Sieyuan Electric supplier in Romania
Instrument transformers 40.5–1,100 kV, coupling capacitors and GIS bushings
Founded in 1993 · Headquarters: Shanghai, China
Who is Sieyuan Electric and what does it make?
Sieyuan Electric Co., Ltd. is a Chinese company from Shanghai, founded in 1993, with a broad portfolio: power transformers, gas-insulated switchgear (GIS), reactors, capacitor banks, relays and FACTS systems. For a substation engineer, the relevant family is that of instrument transformers and bushings.
Oil-filled current transformers, in hair-pin or inverted-head construction, range from 40.5 to 550 kV, with primary currents of 0.5–8,000 A and accuracy classes from 0.2 to TPY. There are also variants with SF6 insulation or without SF6. Capacitor voltage transformers (CVT) cover 40.5–1,100 kV, oil-filled inductive ones 40.5–550 kV, and the coupling capacitor for PLC goes up to 1,000 kV AC. The GIS bushing is offered between 40.5 and 800 kV, and there are also RIP bushings for converter transformers.
Such instruments may be of interest to industrial substations or 110–220 kV ones where a replacement unit with compatible parameters is sought. Variants for low temperature, high altitude and earthquakes are ordered as options, so the request must state the conditions at the site, not just the voltage. The nameplate of the existing unit and the outline drawing are the starting point of the quotation.
What do we supply from the Sieyuan Electric range?
| Product | Description |
|---|---|
| Oil-filled current transformers (hair-pin / inverted head) | Current transformers with oil–paper insulation, 40.5–550 kV, primary current 0.5–8,000 A, secondary 1 A or 5 A. Supplied with a porcelain or composite insulator. |
| Capacitor voltage transformer (CVT) | Capacitor voltage transformer for 40.5–1,100 kV, with SF6 insulation, for high-accuracy metering. Supplied for 50 and 60 Hz. |
| Oil-filled inductive voltage transformers and combined transformers | Oil-filled inductive voltage transformer (40.5–550 kV) and combined CT/VT transformer (40.5–550 kV), with oil–paper insulation. |
| Coupling capacitor and GIS bushing | Coupling capacitor for PLC (alternating current up to 1,000 kV, capacitances of 0.0028 and 0.0052 μF) and GIS bushing between 40.5 and 800 kV, with cable or conduit structure. |
Why Sieyuan Electric?
- Oil-filled current transformers from 40.5 to 550 kV — primary currents of 0.5–8,000 A, classes 0.2 / 0.5 / 0.2S / 0.5S / 5P / 10P / TPS / TPX / TPY
- CVT from 40.5 to 1,100 kV — the same series covers everything from industrial substations to the extra-high-voltage grid
- Custom variants for low temperatures, high altitude and earthquakes — with seismic test reports according to ETG1020 and IEEE-693
- Specific creepage distance of 25 or 31 mm/kV — porcelain or composite insulator at your choice, for polluted environments
- A wide range of substation equipment from the same company — GIS, reactors, capacitor banks and relays, useful for combined orders
Where is Sieyuan Electric equipment used?
- 110–400 kV substations — oil-filled current and voltage transformers
- Industrial substations — metallurgy and petrochemicals with their own high-voltage substation
- Lines with PLC communication — coupling capacitors
- Substations with GIS — GIS-to-air bushings of 40.5–800 kV
- Seismic or high-altitude zones — custom variants
How do we supply Sieyuan Electric in Romania?
For Sieyuan products you can request a quotation by sending the maximum voltage, the primary and secondary current, the accuracy classes and the burden, the standard (IEC or IEEE), the creepage distance wanted, the type of insulator (porcelain or composite) and the site conditions (temperature, altitude, seismic activity). Supplied to order; the equipment is configured, so the lead time can be longer depending on the specification and is confirmed in the quotation. Each request is checked individually.
Documentation, lead times and spare parts are set only once each request has been checked.
Frequently asked questions about Sieyuan Electric
What does Sieyuan Electric make in the area of instrument transformers?
Oil-filled current transformers (40.5–550 kV), with SF6 or without SF6, CVT capacitor transformers (40.5–1,100 kV), inductive ones (40.5–550 kV), combined CT/VT, coupling capacitors for PLC and bushings for GIS and for converter transformers. The company is from Shanghai, since 1993.
How do I choose between a porcelain and a composite insulator?
Both are offered, with a specific creepage distance of 25 or 31 mm/kV. The choice depends on pollution, seismic activity and the unit being replaced. Send the voltage, the site conditions and the outline dimensions.
How quickly do you supply Sieyuan equipment in Romania?
Sieyuan is offered to order. Each unit is configured by voltage, current and accuracy classes, so the lead time can be longer depending on the specification and is set in the quotation.
Can I replace an old current transformer with a Sieyuan one?
It is checked from the nameplate of the old unit: voltage, primary and secondary current, classes, burdens, thermal current and the dimensions of the base. The fit is confirmed only once we see these data, because the new unit must fit on the existing foundation.
What information do you need for a quotation for a CVT?
The grid voltage, the frequency (50 or 60 Hz), the accuracy class (for example 0.2 or 0.5), the rated burden, the PLC requirements, the creepage distance, the type of insulator and the altitude and seismic conditions. With these data we identify the configuration before the quotation.
How do I request a Sieyuan Electric quotation?
Send the Sieyuan Electric code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 23 November 2026 · Sources: Sieyuan Electric Co., Ltd. (manufacturer documentation)