Pfisterer supplier in Romania
DOC, EST and ESG terminations, MSA joints and link boxes, 72.5–550 kV
Founded in 1921 · Headquarters: Winterbach, Germany
Who is Pfisterer and what does it make?
Pfisterer is a German company based in Winterbach, near Stuttgart, which for over a hundred years has made components for insulating and connecting conductors in electrical networks. For the high-voltage market, the important products are accessories for XLPE and EPR cables from 72.5 to 550 kV: terminations, joints and link boxes. The common idea is slip-on technology, in which the prefabricated silicone body is pulled over the cable, with no oil and no gas in service.
The outdoor terminations are called DOC (self-supporting, dry, for 123–170 kV), EST (for mounting on line poles, 72.5–170 kV, without scaffolding), ESS and ESP (oil-filled, with a composite or porcelain insulator, up to 550 kV). For GIS cells and transformers there are ESG and ESU, in the 72.5–300 kV range, plus the CONNEX plug-in connection system, in which the same socket allows the connector type to be changed later without intervening in the equipment. MSA joints with a prefabricated body cover 72.5–550 kV, and the link boxes serve earthing and cross-bonding.
Such items are fitted on 110 kV and 220 kV underground lines, in replacements of old oil-filled terminations with dry-insulation versions and at large wind or photovoltaic parks that export power by cable.
What do we supply from the Pfisterer range?
| Product | Description |
|---|---|
| DOC (self-supporting dry termination) | Outdoor termination with a pre-assembled central unit, for 123–170 kV (DOC123-C39, DOC145-C45, DOC170-C58). It is quick to install and needs no maintenance after commissioning. |
| EST / EST-SUB (dry termination for line pole) | Solid-insulated termination for overhead line poles, 72.5–170 kV. It is pre-mounted on the cable at ground level and lifted together with it, so installation needs no scaffolding. |
| ESG / ESU and CONNEX | ESG for GIS and ESU for transformers, 72.5–300 kV, with a silicone stress cone. CONNEX is the plug-in connection system, with a fixed socket and an interchangeable connector. |
| MSA (slip-on joint) | Straight joint made of prefabricated silicone, for cables with Cu or Al conductor between 72.5 and 550 kV. The variants (for example XKMG, XLG or DO) differ in housing and screen version. |
Why Pfisterer?
- DOC and EST dry terminations — they contain no oil or gas, and EST is mounted on the line pole without scaffolding, which shortens the line outage
- CONNEX system — the socket stays in the equipment and the connector is changed later without intervening inside the transformer or GIS
- MSA joints for 72.5–550 kV — prefabricated silicone body, with indoor and outdoor housing variants and various screen versions
- ESG terminations for GIS in six voltage steps (72.5 / 123 / 145 / 170 / 245 / 300 kV) — cast resin body filled with oil, in vertical or horizontal version
- Link boxes for direct earthing, with surge arresters and for cross-bonding — suitable for both terminations and joints
Which Pfisterer codes and series are requested most often?
| Code | Description |
|---|---|
| DOC123-C39 | Self-supporting dry termination, 123 kV |
| DOC145-C45 | Self-supporting dry termination, 145 kV |
| DOC170-C58 | Self-supporting dry termination, 170 kV |
| EST123-C31L | Dry termination for line pole, 123 kV |
| EST145-C45L | Dry termination for line pole, 145 kV |
| EST170-C53L | Dry termination for line pole, 170 kV |
| EST123-C39-SUB | EST-SUB termination, substation version, 123 kV |
| ESS | Outdoor oil-filled termination, composite insulator, up to 550 kV |
| ESP | Outdoor oil-filled termination, porcelain insulator, up to 550 kV |
| ESG72 | Termination for GIS, 72.5 kV |
| ESG145 | Termination for GIS, 145 kV |
| ESG300 | Termination for GIS, 300 kV |
| ESU | Termination for oil-filled transformer, 72.5–300 kV |
| MSA 123 | Slip-on joint, 123 kV |
| MSA 420 | Slip-on joint, 420 kV |
| MSA 550 | Slip-on joint, 550 kV |
Where is Pfisterer equipment used?
- Transmission networks — underground circuits of 110–400 kV
- Transformer substations — terminations for GIS and transformers
- Overhead lines with cable descent — pole terminations
- Power generation — wind and photovoltaic parks exporting power by cable
- Modernisations — replacing oil-filled terminations with dry versions
How do we supply Pfisterer in Romania?
We can quote Pfisterer accessories for high-voltage cables if you send us the maximum voltage Um, the cable type and cross-section, the diameter over the prepared insulation and the place of installation (outdoor, GIS, transformer, pole). For replacements, the make and series of the existing termination help. We supply to order, usually in 1–4 weeks; for configured assemblies with several items the lead time can be longer and is stated in the quotation.
Installation and tests on site remain the responsibility of the customer's team, and for CONNEX or GIS interfaces from another manufacturer we need the interface drawing before confirming the fit.
Frequently asked questions about Pfisterer
What does Pfisterer make for high-voltage cables?
Outdoor terminations (DOC, EST, ESS, ESP), terminations for GIS and transformers (ESG, ESU, CONNEX), MSA slip-on joints for 72.5–550 kV and link boxes for earthing and cross-bonding. All are for XLPE or EPR cables, with copper or aluminium conductor.
How do I choose between the DOC and EST termination?
DOC is self-supporting and is mounted in the substation as a fixed point, at 123–170 kV. EST is used mainly on the line pole, where it is pre-mounted on the cable at ground level and lifted together with it. We need the voltage, the diameter over the insulation and the place of installation.
How soon do you supply Pfisterer products in Romania?
Pfisterer accessories are supplied to order; for insulated terminations or joints the lead time is usually 1–4 weeks. An assembly of several items, for example joints together with link boxes, can take longer.
Can I replace an old oil-filled termination with a dry one?
Dry terminations are also designed to replace oil-filled ones on existing structures. To check the fit, send the series of the current termination, the maximum voltage, the diameter over the prepared insulation and the dimensions of the base plate or supporting structure.
What information do you need for an MSA joint quotation?
The voltage Um, the cable type and conductor material, the cross-section, the insulation and sheath diameters and the type of screen treatment (continuous, separate or with an earthing link). If link boxes are also included, state the expected overvoltage level.
How do I request a Pfisterer quotation?
Send the Pfisterer code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.