Optocon supplier in Romania
For Optocon we quote FOTEMP instruments from the MN30, HD20, C20, T20, T30 and MS10 series, plus TS3, TS4 and TST probes; we need the application, the number of channels and the temperature range for an accurate quotation.
Headquarters: Dresden, Germany
Who is Optocon and what does it make?
Optocon, based in Dresden, specialises in fibre-optic temperature measurement. FOTEMP systems use probes with a gallium arsenide (GaAs) crystal at the tip of the fibre, with no metal parts in the measuring zone. The signal is not influenced by electromagnetic fields, radio frequency or microwaves, which is exactly the situation inside a power transformer or a high-voltage cell, where classic metal probes (resistance thermometers, thermocouples) are sensitive to the surrounding environment.
The range starts from single-channel instruments and reaches systems with dozens of channels: FOTEMP MN30 (1 channel), HD20 (1 or 2 channels), C15 and C20 (1, 2 or 4 channels), T20 and T30 (2 to 16 channels) and MS10, a modular system with 1 to 40 channels. All cover the range from -200 °C to +300 °C, with a resolution of 0.1 K; accuracy is 0.2 K for the MN30, HD20, MS10, C15 and C20 and 1.0 K for the T20 and T30. Probes are chosen by application: TS2P with an exposed crystal for very small surfaces, TS3 for general use, TS4 with a PTFE sheath for aggressive chemical environments and TST, designed for oil-filled or dry-type transformers.
The relevance is monitoring the hot-spot temperature of the windings, the value that limits the loading and the ageing of the transformer insulation. The same principle applies in switchgear, in laboratories with intense fields and in microwave processes. The company also offers recalibration of the instruments, with a certificate of conformity and a copy of the test results.
What do we supply from the Optocon range?
| Product | Description |
|---|---|
| FOTEMP T30 | Signal conditioner for hot-spot monitoring, with 2 to 16 channels grouped in modules of 4. It is the version oriented to power transformers, where several points in the windings are monitored simultaneously and transmitted to the supervision system. |
| FOTEMP T20 and C20 | Multichannel instruments for industrial applications: the T20 offers 2 to 16 channels, and the C20 offers 1, 2 or 4 channels. They connect to monitoring software with data logging and graphic display for supervising the installation. |
| FOTEMP MS10 | Modular system for 1 to 40 channels, in modules of 10x7TE or 5x14TE. Suited to large installations, where the number of measuring points grows over time and the same type of instrument must be kept. |
| Probes TS2P, TS3, TS4 and TST | Probes with a GaAs crystal at the tip of the fibre: TS2P for very small surfaces, TS3 for general use with a semi-rigid rod, TS4 chemically resistant thanks to a PTFE sheath, and TST for transformers. All are non-metallic and connect to FOTEMP instruments. |
Why Optocon?
- Metal-free probe, with a GaAs crystal — insensitive to electromagnetic fields, radio frequency and microwaves, so it can be used directly next to live windings
- Range -200 °C to +300 °C, with 0.2 K accuracy on most instruments (1.0 K on the T20 and T30) — the same family covers everything from deep sub-zero temperatures to transformer hot spots
- Instruments from 1 channel to 40 channels — you can start with one transformer and extend later to a whole substation
- TST probe dedicated to transformers — designed for oil-filled and dry-type versions, without air inclusions
- The manufacturer's recalibration service in Dresden — the instrument comes back with a certificate of conformity and the test results
Which Optocon codes and series are requested most often?
| Code | Description |
|---|---|
| FOTEMP MN30 | Single-channel instrument, -200 °C to +300 °C |
| FOTEMP HD20 | Instrument with 1 or 2 channels |
| FOTEMP MS10 | Modular system with 1 to 40 channels |
| FOTEMP C15 | Instrument with 1, 2 or 4 channels |
| FOTEMP C20 | Instrument with 1, 2 or 4 channels |
| FOTEMP T20 | Multichannel instrument, 2 to 16 channels |
| FOTEMP T30 | Hot-spot monitoring, 2 to 16 channels |
| TS2P | Probe with exposed GaAs crystal, very small surfaces |
| TS3 | General-purpose probe, semi-rigid rod |
| TS4 | Probe with PTFE sheath, aggressive chemical environments |
| TST | Probe for oil-filled and dry-type transformers |
| FOTEMP ASSISTANT | Configuration and monitoring software |
Where is Optocon equipment used?
- Energy — power transformers, hot-spot monitoring of windings
- Switchgear — temperature measurement in cells and busbars, in intense fields
- High voltage — measuring points where metal probes cannot be used
- Hazardous and nuclear environments — measurement insensitive to radio frequency and microwaves
- Laboratories and processes — microwave heating, test instrumentation
How do we supply Optocon in Romania?
We can quote FOTEMP instruments and the associated probes, starting from the number of measuring points and the type of installation. We supply to order, usually 1–4 weeks; for configurations with many channels the lead time can be longer. For an accurate quotation, send us the type of equipment monitored (oil-filled transformer, dry-type, cell), the number of channels wanted, the temperature range and how the signal must be taken up by your supervision system. If you already have a FOTEMP instrument, tell us the model from the nameplate and, for recalibration, the condition of the probes, and we check the options.
Configurations with a large number of channels or with special fibre lengths are determined at the time of order.
Frequently asked questions about Optocon
What does Optocon make?
Optocon makes fibre-optic temperature measurement systems from the FOTEMP family: instruments with 1 to 40 channels and probes with a gallium arsenide crystal. They are used where metal probes cannot work, especially in power transformers, high-voltage switchgear and environments with microwaves or radio frequency.
How many channels do I need for a power transformer?
The number of channels depends on how many points in the windings you want to monitor. The T20 and T30 instruments offer 2 to 16 channels, and for large installations there is the modular MS10, with up to 40. Send us the measuring layout you want and the transformer type, and we propose the suitable version.
Do you supply Optocon instruments in Romania, and how quickly?
Yes, FOTEMP instruments are supplied to order. The usual lead time is 1–4 weeks, and systems with many channels or with special fibre lengths may need more time. You receive the exact confirmation in the quotation, after the configuration is checked.
Can I replace the probe of an existing FOTEMP instrument?
Compatibility depends on the instrument model and the probe type, so equivalence is confirmed only after checking. For this we need the instrument model from the nameplate, the type of probe fitted and the fibre length, then we confirm what can be supplied.
What data do I need to send for a quotation on fibre-optic systems?
Specify the application (oil-filled transformer, dry-type, cell or process), the number of measuring points, the temperature range, the fibre length and the output required to the supervision system. If you already have an instrument, add the model from the nameplate; it speeds up the check.
How do I request a Optocon quotation?
Send the Optocon code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: COMEM (manufacturer documentation)