Neoptix supplier in Romania
Fibre-optic probes and conditioners for winding temperature
Headquarters: Québec, Canada
Who is Neoptix and what does it make?
Neoptix designs fibre-optic systems for temperature measurement, in particular for the hot spots in the windings of dry-type or oil-filled power transformers. The company is based in Québec. The measuring principle uses a fundamental characteristic of a gallium arsenide semiconductor chip, which means the probes need no calibration and can be exchanged with one another without recalibrating the system.
Why does an optical probe matter? A temperature calculated from a thermal model can differ noticeably from the one measured directly in the winding, while a fibre made of dielectric materials remains insensitive to electromagnetic fields and to voltage, so it can be placed right inside the coil. The T1 and T2 probes cover the range from −80 to 250 °C and are designed to withstand kerosene desorption at the factory, heating tests and prolonged immersion in oil.
In a 110 kV transformer or in a block unit in a power plant, such a system helps with dynamic loading and with estimating the ageing rate of the insulation. The same instruments are used in radio-frequency, microwave and high-voltage laboratories and, in the medical versions, for measurements inside NMR scanners. The industrial field also includes the temperature of cable and busbar surfaces, of generators and other rotating machines, and drying or polymerisation processes.
What do we supply from the Neoptix range?
| Product | Description |
|---|---|
| T/Guard 405 | System with 2 to 16 optical channels for measuring hot spots in transformers. LED display, 32 MB internal memory, analogue and Modbus outputs, 15 W consumption, cabinet or NEMA 4-12 enclosure mounting. |
| TGL and TGL-FL | Compact signal conditioners with 1 to 8 channels, for small and medium transformers, with 4–20 mA outputs and Modbus serial communication. The TGL-FL version is for fluorescence probes, compatible with type 509DW. |
| NMD | Single-channel portable instrument, battery-powered, with recording on an SD card of up to 2 GB. It suits quality control and heating tests at the factory. |
| T1 and T2 probes | Fibre-optic temperature probes for oil-filled and dry-type transformers, range from −80 to 250 °C, no calibration. The fibre withstands kerosene desorption, factory heating and immersion in oil. |
Why Neoptix?
- Fibre-optic probes made of dielectric materials — direct measurement in the winding, unaffected by the electromagnetic field or voltage
- No calibration factor and no recalibration when a probe is changed — replacing a probe needs no adjustments in the system
- T/Guard 405 reads each channel in 250 milliseconds — overloads and load peaks show up almost immediately
- 4–20 mA analogue outputs (0–10 V optional) and Modbus on RS-485 — connection to the control panel or to the substation system
- NMD portable instrument for heating tests — the same probe technology used for factory or acceptance checks
Which Neoptix codes and series are requested most often?
| Code | Description |
|---|---|
| T/Guard 405 | Optical system with 2–16 channels for hot spots |
| T/Guard Link (TGL) | Compact conditioner, 1–8 channels, Modbus |
| TGL-FL | Conditioner for fluorescence probes |
| NMD | Single-channel portable instrument with SD card |
| T1 | Optical probe for transformers, −80...250 °C |
| T2 | Optical probe for windings, used with T/Guard 405 |
| OptiLink | Software for T/Guard acquisition and control |
| QLink | Replacement software for OptiLink and OptiLink-II |
| OmniFlex | Multichannel system with dedicated acquisition software |
| Nomad | Conditioners compatible with the T/Guard software |
Where is Neoptix equipment used?
- Oil-filled power transformers — direct measurement of hot spots in the windings
- Cast dry-type transformers — probes placed in the coil during manufacture
- Generators and rotating machines — temperature monitoring in environments with a strong electromagnetic field
- High-voltage and radio-frequency laboratories — measurements without disturbing the field
- Medical and industrial applications — temperature inside NMR scanners and in drying or polymerisation processes
How do we supply Neoptix in Romania?
We can quote the T/Guard and TGL systems, the NMD portable instrument, the T1 and T2 probes and the installation accessories. We supply to order, usually in 1–4 weeks; configured equipment can have a longer lead time, confirmed in the quotation. For a quotation we need the number of measuring points, the type of transformer (oil-filled or dry-type), the fibre length to the conditioner, the outputs required at the substation and whether the probes are fitted during manufacture or on an existing transformer.
Availability of the current model of a conditioner is checked on the basis of the exact request.
Frequently asked questions about Neoptix
What products does Neoptix make?
Neoptix makes fibre-optic probes and conditioners for temperature measurement, in particular for hot spots in oil-filled or dry-type transformers. T/Guard is the series intended for transformers. The instruments are also used in high-voltage and radio-frequency laboratories and in medical applications.
Why use optical fibre rather than a thermocouple?
The fibre is made of dielectric materials and is not affected by voltage or the electromagnetic field, so it goes inside the winding. The hot spot is thus measured directly, not as a value calculated from a model. The configuration depends on the number of coils and the channels required, and we confirm them in the quotation.
Can you supply Neoptix systems in Romania, and how quickly?
Yes, Neoptix systems are supplied to order; usually 1–4 weeks. We confirm the availability of the model requested before issuing the quotation, and the lead time remains the one in the quotation.
Can I replace a faulty probe without recalibrating the system?
Thanks to the measuring principle, the probes have no calibration factor, so they can be replaced with one another without adjustments. For an order we need the type of the existing probe, the fibre length and the connector type. Compatibility with an older probe is checked by code.
What information do you need for a quotation on a T/Guard system?
Send the number of channels, the transformer type, the outputs required by the substation (analogue or Modbus), the fibre length and whether mounting is in a cabinet or an outdoor enclosure. If you already have a Neoptix system, add the code from its nameplate.
How do I request a Neoptix quotation?
Send the Neoptix code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 22 November 2026 · Sources: Neoptix Canada LP, Wikipedia (manufacturer documentation)