Netcontrol supplier in Romania
Netcon 500 RTU and gateway, SCADA front-end and Netcon 3000 SCADA system
Founded in 1991 · Headquarters: Helsinki, Finland
Who is Netcontrol and what does it make?
Netcontrol is a Finnish company founded in 1991, based in Helsinki. It supplies telecontrol and automation systems for primary and secondary substations, communication gateways for utilities, SCADA systems for control centres and energy monitoring.
The main role of the equipment is to replace a classic single-protocol RTU with an intelligent device. Netcon 500 and Netcon 200 combine a secure gateway, protocol converter and RTU functions, with programmable logic and fault protection functions. They talk simultaneously to several control centres and to several subordinate IEDs or RTUs, with dozens of standard or proprietary protocols, through the NFE communication software. In this way older devices can stay in service.
At control centre level, Netcon 3000 is an open and extensible SCADA system, and Netcon Gateway Server and Netcon GW502-iM serve as front-end between the substations and the central SCADA. Such solutions are used for modernising telecontrol in primary and secondary substations and in distribution networks. A correct quotation starts from the number of substations, the existing protocols and the cybersecurity requirements. Netcon 500 and Netcon 200 are the main substation automation products.
What do we supply from the Netcontrol range?
| Product | Description |
|---|---|
| Netcon 500 and Netcon 200 | Modular substation gateway and RTU, with protocol converter, programmable logic and fault protection functions. It communicates with several master stations and several IEDs at the same time. |
| Netcon 500 OP and Netcon 500 WebHMI | Human-machine interfaces for the substation: Netcon 500 OP is a modern HMI, and WebHMI is the HMI version with a web interface. |
| Netcon Gateway Server and GW502-iM | Gateways and data concentrators for cyber-secure communication between substations and the central SCADA, with support for old serial devices. |
| Netcon 3000 and Netcon 3000 Compact | SCADA system for control centres. The Compact version is an advanced single-user SCADA system on a single computer. |
Why Netcontrol?
- Netcon 500 and Netcon 200 — RTU, secure gateway and protocol converter in a single device, instead of separate equipment
- Dozens of protocols, standard and proprietary, through the NFE software — old devices connect to modern IP systems
- Secure All-IP concept for utilities — the move from fixed-bandwidth serial links to multifunctional IP networks
- Netcon Gateway Server and GW502-iM — SCADA front-end between substations and the central system, with support for old serial devices
- Netcon 3000 SCADA system, based on more than three decades of experience — extensible and fault tolerant
Which Netcontrol codes and series are requested most often?
| Code | Description |
|---|---|
| Netcon 500 | Modular substation gateway and RTU |
| Netcon 200 | Substation RTU and gateway |
| Netcon 500 OP | Modern substation HMI |
| Netcon 500 WebHMI | Substation HMI accessible through a browser |
| Netcon 3000 | SCADA system for control centres |
| Netcon 3000 Compact | Advanced single-user SCADA |
| Netcon Gateway Server | Gateway and SCADA front-end for substations |
| Netcon GW502-iM | Communication gateway for utilities |
| Netcon 2 | Actuator for disconnectors and load-break switches |
| NFE | Communication software with dozens of protocols |
| DOME | Cybersecurity solution |
Where is Netcontrol equipment used?
- Primary and secondary substations — telecontrol, gateway and RTU
- Electricity transmission and distribution — SCADA front-end and communication
- Renewable energy — automation and monitoring of production
- District heating and energy-intensive industry — telecontrol and monitoring
- Electric rail traction — power supply and automation
How do we supply Netcontrol in Romania?
We can quote Netcontrol telecontrol, gateway and communication equipment, based on the data of your substation. We supply to order; common parts usually arrive within 1–4 weeks, while configured systems and projects with software may need longer, confirmed in the quotation. For a correct quotation send us the existing model (for example Netcon 500 or GW502-iM), the list of protocols towards the control centre and towards the devices in the substation, the number of inputs and outputs and the cybersecurity requirements.
For a model being phased out of the range, availability is checked by code, on request.
Frequently asked questions about Netcontrol
What products does Netcontrol make?
Netcontrol, from Helsinki (Finland), has made telecontrol and automation systems for substations since 1991, as well as communication gateways, SCADA systems for control centres, cybersecurity solutions and energy monitoring.
How do I choose between Netcon 500 and Netcon 200?
Both are main substation automation products, acting as RTU, gateway and protocol converter. The number of inputs and outputs, the protocols and the protection functions required matter. Send us the substation diagram for checking.
Can you supply Netcontrol equipment in Romania, and within what lead time?
Yes, for Netcontrol, to order; usually 1–4 weeks for items. Systems with software and configuration may need longer, and the exact lead time is confirmed in the quotation.
Can I connect old equipment to a Netcontrol gateway?
Netcontrol gateways are designed for old serial devices and various protocols, but each case is checked. Send us the make and model of the device, the protocol, the serial line speed and the physical interface. Compatibility is confirmed from these data.
What data do you need for a quotation for a Netcon 3000 SCADA system?
State the number of substations and data points, the communication protocols, the number of operators and workstations, the redundancy and security requirements, and the existing SCADA system, if a migration follows.
How do I request a Netcontrol quotation?
Send the Netcontrol code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 23 November 2026 · Sources: Netcontrol Oy (manufacturer documentation)

