Skip to content
+40 371 232 404|Mon - Fri: 08:00 - 16:30 (Romania time)

Morgan Schaffer supplier in Romania

Calisto online DGA monitors for transformer oil

Founded in 1965 · Headquarters: Montréal, Canada

Request a quote

Who is Morgan Schaffer and what does it make?

Morgan Schaffer is a manufacturer from Montréal, founded in 1965, of equipment for dissolved gas analysis (DGA) in transformer oil. The name is linked to the Calisto family of online monitors, the Myrkos portable analysers, dielectric oil analysis laboratories and the gas-in-oil standards used to calibrate laboratory instruments. For whoever is responsible for a power transformer, the point is to learn early that the insulation is suffering, before a fault turns into a failure.

The Calisto range grows in steps. The simple model detects hydrogen and moisture, Calisto 2 adds carbon monoxide to track cellulose degradation, Calisto 5 and 9 use gas chromatography for fault gases and moisture, and Calisto R9 measures by photoacoustic infrared spectroscopy and self-calibrates with water vapour, so without calibration gas cylinders. Calisto T1 brings together bushing monitoring, partial discharge and input and output modules in a single unit. Communication is through Modbus, DNP3 and, optionally, IEC 61850.

Such monitors are fitted in 110–400 kV substations and on unit transformers in power plants, where an operator can move from periodic sampling to continuous reading. The choice of model depends on how critical the transformer is and on how many gases have to be tracked, from simple hydrogen alarming up to diagnosis with the Duval triangle.

What do we supply from the Morgan Schaffer range?

ProductDescription
Calisto 9Complete DGA monitor with moisture, based on gas chromatography, with an in-house cell. Modbus, DNP3 and optional IEC 61850, solubility compensation for the usual insulating liquids, useful life of more than 15 years.
Calisto R9DGA monitor with an infrared method (DIPAS) and thermal conductivity for hydrogen, with water-vapour self-calibration. Vacuum-tolerant membrane extraction, sludge-tolerant pump and installation in less than two hours.
Calisto 2Monitor for hydrogen, moisture and carbon monoxide. Hydrogen indicates incipient faults, and carbon monoxide helps track the degradation of the cellulose in the solid insulation. Moisture is measured continuously, in the same instrument, to follow the condition of the oil.
Calisto T1Transformer monitoring system: bushings, partial discharge and input and output modules in one configurable unit, with an integrated server for managing users and alerts and for viewing data, without extra software.

Why Morgan Schaffer?

  • Calisto R9 self-calibrates with water vapour — maintenance no longer includes replacing calibration gas cylinders
  • Calisto 5 and 9 measure by gas chromatography — fault gases can be tracked for fault classification, including with the Duval triangle
  • Calisto and Calisto 2 models — hydrogen and moisture, with carbon monoxide on model 2, suited to large fleets of transformers
  • Modbus, DNP3 and optional IEC 61850 communication — integration into substation automation uses common protocols
  • Monitor, gas-in-oil standards and Inside View interpretation software in the same range — DGA data are compared along a coherent chain

Which Morgan Schaffer codes and series are requested most often?

CodeDescription
CalistoHydrogen and moisture monitor
Calisto 2Hydrogen, moisture and carbon monoxide monitor
Calisto 5Monitor with five fault gases and moisture (chromatography)
Calisto 9Complete DGA monitor with moisture (chromatography)
Calisto R9Infrared DGA monitor, water-vapour self-calibration
Calisto T1System for bushings, partial discharge and inputs/outputs
MyrkosPortable gas analyser, on-site DGA
Inside ViewSoftware for interpreting oil analysis data
True NorthGas-in-oil and moisture-in-oil standards
AtlantisCalibration standards for gas-in-oil analysis
MS Oil LIMSLaboratory sample management software

Where is Morgan Schaffer equipment used?

  • Power transformers in 110–400 kV substations — online DGA and moisture monitoring
  • Unit transformers in power plants — fault gas supervision
  • Dielectric oil laboratories — calibration with gas-in-oil standards
  • Predictive maintenance in transmission networks — integration with SCADA through Modbus or DNP3
  • Industrial operators with critical transformers — portable analysis on site

How do we supply Morgan Schaffer in Romania?

We can quote the Calisto monitors, the Myrkos portable analysers and the calibration standards from the Morgan Schaffer portfolio. Supplied to order, usually in 1–4 weeks; for configured systems the lead time may be longer and is confirmed in the quotation. To prepare a correct request, send the type and rating of the transformer, the type of insulating liquid (mineral, ester), the gases you want to track, the substation protocol (Modbus, DNP3, IEC 61850) and whether you need fixed monitoring or analysis on site.

The Calisto model suited to a transformer is established from its rating, the insulating liquid and the gases tracked.

Frequently asked questions about Morgan Schaffer

What does Morgan Schaffer make?

Morgan Schaffer is known for the Calisto online monitors for dissolved gas analysis in transformer oil, for the Myrkos portable analysers and for gas-in-oil standards.

What is the difference between Calisto 2, Calisto 5 and Calisto 9?

Calisto 2 tracks hydrogen, moisture and carbon monoxide, so it signals incipient faults and cellulose degradation. Calisto 5 adds gases for diagnosis, and Calisto 9 offers the complete set of gases plus moisture. For a recommendation we need to know how important the transformer is.

Can Calisto monitors be supplied in Romania, and in what time?

Yes, Calisto monitors can be supplied to order. The lead time is usually 1–4 weeks, but monitors configured for a substation may need longer. The final dates are confirmed in the quotation, after the configuration is checked.

Can I add a Calisto to a transformer already in service?

In principle yes: with the Calisto R9, field installation usually takes less than two hours. For confirmation we need to know the type of oil valve, the access to power supply and the communication protocol existing in the substation.

What data do you need for a quotation on a DGA monitor?

Send the rating and voltage of the transformer, the type of oil, the gases of interest, the level of criticality, the substation protocol and the number of units. A photo of the nameplate and of the connection valve helps with the quotation. If you only track hydrogen and moisture, a simple version may be enough.

How do I request a Morgan Schaffer quotation?

Send the Morgan Schaffer code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.

Request a quote

Updated: 22 November 2026 · Sources: Doble Engineering Company (manufacturer documentation)