HIGHVOLT Prüftechnik Dresden supplier in Romania
For HIGHVOLT we quote AC test systems, resonant systems, DiTAS for distribution transformers, portable WV units, DC systems and impulse generators; for a quotation we need the test object, the test voltage and the applicable standard.
Headquarters: Dresden, Germany
Who is HIGHVOLT Prüftechnik Dresden and what does it make?
HIGHVOLT Prüftechnik Dresden GmbH is a German manufacturer of high-voltage test and measuring systems, based in Dresden, where its line of work continues a tradition that began in 1904. The halls in Dresden allow system tests up to 1,600 kV AC and 2,200 kV DC, which means the manufacturer can test large systems itself.
The range is divided by voltage type. AC test systems with a transformer (WP series) and with a transformer in a metal tank (WP G) are used to test cables, power transformers and other high-voltage equipment. Resonant systems (WR, WRU, WRM) and variable-frequency systems (WRV T, WRV M), between 10 and 300 Hz, perform withstand voltage tests on cables according to IEC 60840, IEC 62067 and IEC 63026 for offshore wind farm cables, on installed transformers and on gas-insulated substations (GIS). WRV 20/75 T is the mobile version for 6–69 kV cables.
For transformers there is DiTAS (distribution transformers according to IEC 60076) and the portable WV 18-18/1.4 source, for induced voltage and partial discharge tests on distribution transformers up to 8 MVA. DC systems reach 2,000 kV according to IEC 60060-2, and impulse generators (IP series) produce lightning-type voltage impulses. In Romania the relevant users are transformer manufacturers and repairers, electrical test laboratories and operators who test cables.
What do we supply from the HIGHVOLT Prüftechnik Dresden range?
| Product | Description |
|---|---|
| AC test systems (WP, WP G, WGSBS) | Systems with a test transformer, in dry-insulated or metal-tank versions, for cables, power transformers and other high-voltage equipment. The WGSBS module combines AC up to 100 kV, DC up to 135 kV and impulse. |
| Resonant and variable-frequency systems (WR, WRU, WRM, WRV T) | Systems that use the resonance between the capacitive test object and the high-voltage reactor. WRV T operates between 10 and 300 Hz and is used on cables, installed transformers and GIS, with a low supply power thanks to the reactor. |
| Transformer systems (DiTAS, WV) | DiTAS is the system for type, routine and special tests on distribution transformers according to IEC 60076, with a frequency converter from 16⅔ to 200 Hz. WV 18-18/1.4 is a portable three-phase source for partial discharge tests. |
| DC, impulse and high-current systems (GPM, IP) | DC systems up to 2,000 kV according to IEC 60060-2, with the modular GPM version and container or trailer solutions. IP impulse systems generate lightning-type impulses (1.2/50 µs), and high-current systems heat the test objects. |
Why HIGHVOLT Prüftechnik Dresden?
- System tests up to 1,600 kV AC and 2,200 kV DC in the Dresden hall — large systems proven before delivery
- Variable-frequency resonance 10–300 Hz (WRV T) — withstand voltage testing of cables with cross-linked polyethylene (XLPE) insulation according to IEC 60840 and IEC 62067
- Mobile WRV 20/75 T for 6–69 kV cables — for work on site, in a transportable configuration
- Portable WV 18-18/1.4 — induced voltage and partial discharge measurement on distribution transformers up to 8 MVA
- Combined modules (WGSBS) — AC up to 100 kV, DC up to 135 kV and impulse in a single system, with efficient use of space
Which HIGHVOLT Prüftechnik Dresden codes and series are requested most often?
| Code | Description |
|---|---|
| WP | AC test system with transformer |
| WP G | AC system with transformer in a metal tank, continuous duty |
| WGSBS | Test module: AC 100 kV, DC 135 kV, impulse |
| WR | AC resonant system with variable inductance |
| WRU | AC resonant system with variable inductance |
| WRM | Resonant system with cascading option |
| WRV T | Variable-frequency AC system, 10–300 Hz, cables |
| WRV M | Variable-frequency AC system for installed transformers |
| WRV 20/75 T | Mobile resonant system for 6–69 kV cables |
| DiTAS | Test system for distribution transformers |
| WV 18-18/1.4 | Portable three-phase source for partial discharge |
| GPM | Modular DC test system |
| IP | Voltage and current impulse systems |
| HiMON | Cable monitoring system |
Where is HIGHVOLT Prüftechnik Dresden equipment used?
- Transformer manufacturers and repairers — routine and type tests
- Manufacturers and operators of high-voltage cables, including offshore wind farms
- Gas-insulated substations (GIS) — withstand voltage tests at commissioning
- Electrical test laboratories — AC, DC and impulse
- Cable monitoring — the HiMON system on lines in service
How do we supply HIGHVOLT Prüftechnik Dresden in Romania?
We quote HIGHVOLT high-voltage test systems: the WP, WR, WRV and DiTAS series, DC and impulse systems, and parts of them, starting from the test object. These are custom-designed systems, so the lead time can be longer, depending on the specification, and is confirmed in the quotation. Supplied to order. For a correct request we need the object to be tested (cable, transformer, GIS), the test voltage and current, the applicable standard, the capacitive load and whether the system is installed in a laboratory or is mobile.
The sizing of a resonant system for a given cable depends on the capacitance of the object and on the test voltage, and is set in the configuration confirmed in the quotation, based on the data sent.
Frequently asked questions about HIGHVOLT Prüftechnik Dresden
What does HIGHVOLT Prüftechnik Dresden make?
HIGHVOLT makes high-voltage test and measuring systems in Dresden: AC systems with a transformer, variable-frequency resonant systems, DC and impulse systems, installations for transformers, partial discharge measurement and HiMON cable monitoring.
How do I choose between a resonant system and one with a test transformer?
For strongly capacitive objects, such as long cables, resonance needs a much lower supply power and is the usual choice. For objects with a low load and short tests, a test transformer (WP) is sufficient. Send us the capacitance of the object, the test voltage and the test duration.
Do you supply HIGHVOLT systems in Romania and how fast?
They are supplied to order. These are custom-designed systems, so the lead time can be longer; the exact lead time is given in the quotation, after the configuration and the applicable test standards have been clarified.
Can an existing HIGHVOLT test system be extended?
An extension is established once we know which system is in place. Send us the system series, the rated voltage and the installed components (transformer, reactor, divider), and we check which modules, reactors or accessories can be added to the existing configuration.
What data do I need to send for a quotation for DiTAS or a transformer system?
State the power and voltage of the transformers to be tested, the standard (for example IEC 60076), whether the test is in the factory or in the field, the frequency required and the need for partial discharge measurement. If you already have a test location, also mention the available power supply.
How do I request a HIGHVOLT Prüftechnik Dresden quotation?
Send the HIGHVOLT Prüftechnik Dresden code from the nameplate and the quantity; we reply in English with availability and the lead time written in the quotation.
Request a quoteUpdated: 21 November 2026 · Sources: HIGHVOLT Prüftechnik Dresden GmbH (manufacturer documentation)